About Wire and Cable
Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.
Building Wire
Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
Shorter Lengths | Longer Lengths | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Cable Designation | Certification | Flammability Rating | Choose an Outer Jacket Color | Choose a Length, ft. | Per Ft. | Lg., ft. | Each | ||||
600V AC/600V DC | ||||||||||||||||
| 4 | 19/17 | 95 amp @ 86° F | 0.32" | -10 to 190 | THHN, THWN-2 | C-UL Listed, UL Listed | UL 2556 VW-1 | Black, Blue, Brown, Green, Orange, Red, White, Yellow | 10, 25, 50, 100, 250 | 7715T18 | 00000 | 500 | 7715T58 | 0000000 | ||
Stranded Wire with Polyethylene Outer Jacket
Power Cable
Outer Jacket | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Temp., ° F | Flammability Rating | Certification | Choose a Length, ft. | Per Ft. | |||
600V AC | |||||||||||
SOOW Cable | |||||||||||
| 4/3 | 70 amp @ 86° F | EPDM | Black | -40 to 190 | UL 2556 FT2 | CSA Certified, UL Listed | 10, 25 | 7081K3 | 000000 | ||
| 4/4 | 60 amp @ 86° F | EPDM | Black | -40 to 190 | UL 2556 FT2 | CSA Certified, UL Listed | 10, 25, 50, 100, 250 | 7081K28 | 00000 | ||
| 4/5 | 48 amp @ 86° F | CPE | Black | -40 to 190 | UL 2556 FT2 | CSA Certified, UL Listed | 10, 25, 50, 100, 250 | 7081K29 | 00000 | ||
Welding Cable
![]() | |
AWG | Stranded Wire Class | Wire Strand Count | Current @ Temp. | Outer Jacket Material | Temp., ° F | Flammability Rating | Choose an Outer Jacket Color | Choose a Length, ft. | Per Ft. | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||
Bend and Stay | ||||||||||||
| 4 | K | 364/30 | — | EPDM | -55 to 220 | UL 2556 VW-1 | Black, Red | 10, 20, 25, 30, 50, 100, 250 | 7940A92 | 00000 | ||
600V AC/600V DC | ||||||||||||
Ultra Flexible | ||||||||||||
| 4 | — | 385/30 | 140 amp @ 86° F | EPDM | -40 to 190 | — | Black, Red | 10, 25, 50, 100 | 6948K92 | 0000 | ||
Battery Wire
High-Temperature Lead Wire
Temp., ° F | Per Ft. | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Min. | Max. | Outer Jacket Color | Flexibility | Cable Designation | Wire Material | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
Stranded Wire with Fiberglass Fabric Outer Jacket and Mica Inner Insulation | ||||||||||||||||
600V AC/600V DC | ||||||||||||||||
| 4 | 133/25 | 235 amp @ 86° F 167 amp @ 600° F | 0.37" | -40 | 840 | Beige | Flexible | MG | Nickel-Plated Copper | CSA Certified, UL Listed | 5, 10, 25, 50 | 8209K24 | 000000 | 000000 | ||
Outdoor Lead Wire
600V AC/600V DC
Per Ft. | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Material | Outer Jacket Color | Cable Designation | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Stranded Wire | |||||||||||||||
| 4 | 429/30 | 140 amp @ 86° F | 0.51" | -55 to 220 | EPDM | Black | SC | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT5 | 10, 25, 50, 100 | 6584T16 | 00000 | 00000 | ||
2,000V AC
AWG | Current @ Temp. | OD | Max. Temp., ° F | Outer Jacket Material | Inner Insulation Material | Outer Jacket Color | Cable Designation | Certification | Flammability Rating | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire | ||||||||||||||||
| 4 | 95 amp @ 86° F | 0.44" | 190 | CPE | EPDM | Black | DLO, RHW-2 | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T28 | 000000 | 0000000 | 0000000 | 0000000 | ||
Vehicle Cable
Grounding Wire
Flexible Grounding Wire
![]() | ![]() |
Noninsulated Solid | Noninsulated Stranded |
Heavy Duty Harsh-Environment Power Cable
High-Voltage Continuous-Flex Lead Wire
Stranded Wire with Silicone Rubber Outer Jacket
Per Ft. | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | Temp. Range, ° F | OD | Outer Jacket Color | Performance | Environment | Clean Room Std. | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Unshielded | ||||||||||||||||
Tin-Plated Copper Wire—59,000V AC/42,000V DC | ||||||||||||||||
| 4 | 1,666/36 | 125 amp @ 86° F | -85 to 325 | 0.5" | Clear | High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T25 | 000000 | 000000 | ||
Chemical-Resistant Continuous-Flex Lead Wire
Stranded Wire with TPE Outer Jacket
Per Ft. | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Current @ Temp. | Temp. Range, ° F | OD | Torsion Angle | Outer Jacket Color | Performance | Environment | Clean Room Std. | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Unshielded | ||||||||||||||||
Copper Wire—1,000V AC | ||||||||||||||||
| 4 | 131 amp @ 86° F | -30 to 190 | 0.45" | 90° | Black | Chemical Resistant, Flame Retardant | Clean Room | ISO Class 1 | C-UL Recognized Component, UL Recognized Component | UL 2556 FT1 | 10, 25, 50, 100 | 9192K15 | 000000 | 00000 | ||
Shielded—Spiral Shield | ||||||||||||||||
Copper Wire—1,000V AC | ||||||||||||||||
| 4 | 128 amp @ 86° F | -30 to 190 | 0.57" | 180° | Black | Chemical Resistant, Flame Retardant | Clean Room | ISO Class 1 | C-UL Recognized Component, UL Recognized Component | UL 2556 FT1 | 10, 25, 50, 100 | 9192K57 | 00000 | 00000 | ||
Corrosion-Resistant Battery Wire
Continuous-Flex Power Cable
Outer Jacket | Per Ft. | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Bend Radius | Material | Color | Temp., ° F | Flammability Rating | Certification | Clean Room Std. | Choose a Length, ft. | 1-99 | 100-Up | |||
1,000V AC | ||||||||||||||
Unshielded | ||||||||||||||
| 4/4 | 121 amp @ 86° F | 7.5" | PVC | Black | 25 to 155 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | ISO Class 2 | 5, 10, 20, 30, 50, 100 | 9243K22 | 000000 | 000000 | ||
Shielded | ||||||||||||||
| 4/4 | 121 amp @ 86° F | 8.4" | PVC | Black | 25 to 155 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | ISO Class 2 | 5, 10, 20, 30, 50, 100 | 9243K42 | 00000 | 00000 | ||
Aluminum Building Wire
AWG | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Color | Cable Designation | Certification | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | 500 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation | ||||||||||||||
600V AC/600V DC | ||||||||||||||
| 4 | 75 amp @ 86° F | 0.3" | -40 to 190 | Black | THHN, THWN-2 | UL Listed | 6082N12 | 000000 | 000000 | 000000 | 0000000 | 0000000 | ||
Harsh-Environment Power Cable
Outer Jacket | Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Temp., ° F | Specs. Met | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
600V AC | ||||||||||||
Type P Cable | ||||||||||||
| 4/4 | 68 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 5, 10, 25, 50 | 8248K27 | 000000 | 000000 | ||
Type P Cable with Bronze Armor | ||||||||||||
| 4/4 | 68 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 5, 10, 25, 50 | 8248K57 | 00000 | 00000 | ||
Battery Power Cords
Terminal Clamp × Lug
Cord | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Lg. | Lug ID | End Shape | OD | Insulation Material | Connection Material | Temp. Range, ° F | Choose a Color (Polarity) | Each | ||
| 4 | 10" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K51 | 000000 | |
| 4 | 20" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K52 | 00000 | |
| 4 | 30" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K53 | 00000 | |
| 4 | 60" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K54 | 00000 | |
Lug with Terminal × Lug
Cord | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Lg. | Lug ID | End Shape | OD | Insulation Material | Connection Material | Temp. Range, ° F | Choose a Color (Polarity) | Each | ||
| 4 | 10" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K21 | 000000 | |
| 4 | 20" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K22 | 00000 | |
| 4 | 30" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K23 | 00000 | |
| 4 | 60" | 3/8" | Straight | 0.35" | PVC | Tin-Plated Copper | -40 to 220 | Black (Negative), Red (Positive) | 69735K24 | 00000 | |
Variable-Frequency Drive Motor Cable
Power Wire— Stranded with PVC Outer Jacket
Power Wire | Inner Insulation | Per Ft. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | AWG | Cable AWG | Current @ Temp. | OD | Outer Jacket Color | Material | Color | Temp. Range, ° F | Cable Designation | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
Double Shielded—1,000V AC/1,500V DC | ||||||||||||||||
| 4 | 4 | 4/4 | 70 amp @ 86° F | 1.19" | Black | Nylon, PVC | Black, Green/Yellow | -40 to 220 | WTTC | UL Listed, C-UL Listed | 5, 10, 20, 30, 50, 100 | 7777T26 | 000000 | 000000 | ||
Braided Grounding Straps
Flexible with Lug Connection
AWG Equiv. | Hole Dia. | Wd. | Thk. | Material | Lg. | Each | |||
|---|---|---|---|---|---|---|---|---|---|
Noninsulated | |||||||||
| 4 | 3/8" | 7/8" | 1/16" | Tin-Plated Copper | 9" | 69925K32 | 000000 | ||
| 4 | 3/8" | 7/8" | 1/16" | Tin-Plated Copper | 13" | 69925K34 | 00000 | ||
| 4 | 3/8" | 7/8" | 1/16" | Tin-Plated Copper | 24" | 69925K36 | 00000 | ||
| 4 | 3/8" | 7/8" | 1/16" | Tin-Plated Copper | 30" | 69925K11 | 00000 | ||
| 4 | 3/8" | 7/8" | 1/16" | Tin-Plated Copper | 36" | 69925K12 | 00000 | ||
| 4 | 3/8" | 7/8" | 1/16" | Tin-Plated Copper | 48" | 69925K13 | 00000 | ||
Flame-Resistant Welding Cable
Easy-Insert Lay-In Wire Taps
Wire Taps | Covers | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Wire | For Tap Wire | ||||||||||||
Ga. | Construction | Material | Ga. | Construction | Terminal Material | Max. Temp., ° F | Max. Voltage, V AC | Certification | Each | Each | |||
| 12 to 2 12 to 10 | Stranded Solid | Aluminum, Copper | 12 to 4 12 to 4 | Stranded Solid | Tin-Plated Aluminum | 190 | 600 | CSA Certified, UL Listed | 4296N11 | 000000 | 4296N14 | 00000 | |
| 2 to 1/0 12 to 10 | Stranded Solid | Aluminum, Copper | 12 to 1/0 12 to 1/0 | Stranded Solid | Tin-Plated Aluminum | 190 | 600 | CSA Certified, UL Listed | 4296N12 | 00000 | 4296N15 | 0000 | |
| 1/0 to 250 MCM 12 to 10 | Stranded Solid | Aluminum, Copper | 12 to 1/0 12 to 1/0 | Stranded Solid | Tin-Plated Aluminum | 190 | 600 | CSA Certified, UL Listed | 4296N13 | 00000 | 4296N16 | 00000 | |
No-Conduit-Required Control Cable
Outer Jacket | Per Ft. | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Cable Designation | Temp., ° F | Flammability Rating | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
600V AC | |||||||||||||
Unshielded | |||||||||||||
| 4/4 | 95 amp @ 86° F | PVC | Black | TC-ER | -10 to 190 | UL 2556 FT4 | C-UL Listed, CSA Certified, UL Listed | 5, 10, 20, 30, 50 | 6452T78 | 000000 | 000000 | ||
Double Shielded | |||||||||||||
| 4/4 | 95 amp @ 86° F | PVC | Black | TC-ER | -10 to 190 | UL 2556 FT4 | C-UL Listed, CSA Certified, UL Listed | 5, 10, 20, 30, 50 | 6452T88 | 00000 | 00000 | ||
Distribution Blocks
Screw-Clamp Terminal Input Connection
Distribution Blocks | End Stops | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Connections Per Circuit | ||||||||||||||||
Current per Circuit, amp | Voltage | Input (For Wire Ga.) | Output (For Wire Ga.) | Wd. | Ht. | Dp. | Enclosure Rating | Certification | Flammability Rating | Features | Each | Each | ||||
DIN-Rail Mount | ||||||||||||||||
1 Circuit | ||||||||||||||||
| 115 | 600V AC/600V DC | 1 (14-2) | 1 (14-2) | 3/4" | 4 1/8" | 1 11/16" | IP20 | UL Listed, CE Marked | UL 94 V-0 | — | 6367T25 | 000000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T11 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T14 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover, Quick-Disconnect Load Connection | 6367T22 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T17 | 00000 | ——— | 0 | ||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 4 (14-2) | 1 1/8" | 3 5/8" | 2 11/16" | IP20 | UL Listed, CSA Certified, CE Marked | UL 94 V-0 | — | 6367T27 | 00000 | ——— | 0 | ||
| 230 | 1,000V AC/1,000V DC | 1 (2-250 MCM) | 2 (14-2), 5 (14-6), 4 (14-8) | 1 13/16" | 3 3/4" | 2 3/8" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | — | 6367T21 | 00000 | 7641K35 | 00000 | ||
| 335 | 600V AC/600V DC | 1 (6-400 MCM) | 8 (14-2) | 2 1/4" | 4 3/4" | 3 5/16" | IP20 | UL Recognized Component, CE Marked | UL 94 V-0 | — | 6367T28 | 00000 | ——— | 0 | ||
| 335 | 1,000V AC/1,000V DC | 1 (3/0-400 MCM) | 2 (14-2), 5 (14-6), 4 (14-8) | 1 13/16" | 3 3/4" | 2 3/8" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Jumper Cable Terminal | 6367T53 | 00000 | 7641K35 | 0000 | ||
2 Circuits | ||||||||||||||||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T12 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T15 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover, Quick-Disconnect Load Connection | 6367T23 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T18 | 00000 | ——— | 0 | ||
3 Circuits | ||||||||||||||||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T13 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T16 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover, Quick-Disconnect Load Connection | 6367T24 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T19 | 000000 | ——— | 0 | ||
Surface Mount | ||||||||||||||||
1 Circuit | ||||||||||||||||
| 335 | 600V AC/600V DC | 2 (14-4/0) | 8 (14-2) | 2 1/4" | 4 3/8" | 3 3/16" | IP20 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Extendable | 6367T43 | 00000 | ——— | 0 | ||
| 760 | 600V AC | 2 (4-4/0) | 8 (14- 2/0) | 2 1/2" | 4.63" | 3 3/8" | IP20 | UL Listed, CSA Certified, CE Marked | UL 94 V-0 | Extendable | 6367T45 | 000000 | ——— | 0 | ||
| 760 | 600V AC/600V DC | 2 (4-4/0) | 12 (14-4) | 2 1/2" | 4.63" | 3 3/8" | IP20 | UL Listed, CSA Certified, CE Marked | UL 94 V-0 | Extendable | 6367T41 | 000000 | ——— | 0 | ||
3 Circuits | ||||||||||||||||
| 335 | 600V AC/600V DC | 1 (14-4/0) | 6 (14-2) | 5 5/8" | 5" | 3 15/16" | — | UL Listed, C-UL Listed | — | — | 6367T46 | 000000 | ——— | 0 | ||
| 350 | 600V AC/600V DC | 2 (14-2/0) | 6 (14-4) | 5 5/8" | 5" | 3 15/16" | — | UL Listed, C-UL Listed | — | — | 6367T44 | 000000 | ——— | 0 | ||
| 510 | 600V AC/600V DC | 2 (6-4/0) | 8 (14-2) | 5 5/8" | 5" | 3 15/16" | — | UL Listed, C-UL Listed | — | — | 6367T42 | 000000 | ——— | 0 | ||
Stud-Terminal Input Connection
No. of Connections Per Circuit | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current per Circuit, amp | Voltage | Input (For Wire Ga.) | Output (For Wire Ga.) | Terminal Size | Wd. | Ht. | Dp. | Certification | Flammability Rating | Features | Each | |||
DIN-Rail Mount | ||||||||||||||
1 Circuit | ||||||||||||||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 1" | 3" | 2 9/16" | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T34 | 000000 | ||
2 Circuits | ||||||||||||||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 2" | 3" | 2 9/16" | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T35 | 00000 | ||
3 Circuits | ||||||||||||||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 2 5/8" | 3" | 2 9/16" | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T36 | 00000 | ||
Surface Mount | ||||||||||||||
1 Circuit | ||||||||||||||
| 310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 2" | 4" | 3 1/2" | UL Recognized Component, CSA Certified | UL 94 V-0 | Detachable Cover | 6367T37 | 00000 | ||
2 Circuits | ||||||||||||||
| 310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 3 5/8" | 4" | 3 1/2" | UL Recognized Component, CSA Certified | UL 94 V-0 | Detachable Cover | 6367T38 | 000000 | ||
3 Circuits | ||||||||||||||
| 310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 5 3/8" | 4" | 3 1/2" | UL Recognized Component, CSA Certified | UL 94 V-0 | Detachable Cover | 6367T39 | 000000 | ||
Bus-Bar Input Connection
Distribution Blocks | End Stops | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Connections Per Circuit | Bus Bar, mm | ||||||||||||||||
Current per Circuit, amp | Voltage | Input (For Wire Ga.) | Output (For Wire Ga.) | Wd. | Ht. | Dp. | Wd. | Thk. | Enclosure Rating | Certification | Flammability Rating | Each | Each | ||||
DIN-Rail Mount | |||||||||||||||||
1 Circuit | |||||||||||||||||
| 420 | 1,000V AC/1,000V DC | 1 | 2 (14-2), 4 (14-8), 5 (14-6) | 1 13/16" | 4" | 2 3/8" | 25 | 10 | IP20, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | 6367T56 | 000000 | 7641K35 | 00000 | ||
Jumper Cables
Wire | Clamp | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Max. Current, amp | AWG | Construction | Material | Insulation Material | Material | Insulation Material | Temp. Range, ° F | Pair | ||
| 12 | 500 | 4 | Stranded | Copper | PVC | Metal | PVC | -40 to 175 | 7234K12 | 0000000 | |
| 16 | 500 | 4 | Stranded | Copper | PVC | Metal | PVC | -40 to 175 | 7234K18 | 000000 | |
| 20 | 500 | 4 | Stranded | Copper | PVC | Metal | PVC | -40 to 175 | 7234K19 | 000000 | |
| 25 | 500 | 4 | Stranded | Copper | PVC | Metal | PVC | -40 to 175 | 7234K23 | 000000 | |