Wire Gauge Wire Gauge |
---|
Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
System of Measurement System of Measurement |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Voltage Voltage |
---|
|
|
Wire Type Wire Type |
---|
![]() | |
Use For Use For |
---|
|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Ultra Flexible |
![]() |
Flexible |
Specifications Met Specifications Met |
---|
|
Wire Material Wire Material |
---|
|
Inner Insulation Marking Inner Insulation Marking |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
Current Current |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Cable

Use this general purpose cable to supply power to equipment.
For technical drawings and 3-D models, click on a part number.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
16 | 6 | 16/6 | 8 A @ 86° F | 0.52" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 |
Coiled Cable

After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
Ultra-flexible cable extends and retracts more easily than flexible cable.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJOW and SOW have a multipurpose neoprene insulation. SJEOW and SEOW have a TPE rubber insulation that also withstands chemicals.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
300V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16 | 6 | 16/6 | 7 A @ 86° F | 0.46" | 1.67" | Black | Black, Blue, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
600V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16 | 6 | 16/6 | 7 A @ 86° F | 0.58" | 2" | Black | Black, Blue, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 |
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
20,000V DC/28,000V AC | ||||||||||||||
16 | 6 | 16/6 | 26 A @ 86° F | 0.7" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 000000 | 000000 |