About Wire and Cable
More
High-Voltage Continuous-Flex Flat Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
12,000V DC/17,000V AC | |||||||||||||||
24 | 10 | 24/10 | 8 A @ 86° F | 0.62" | 0.09" | 1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 000000 | 00000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Temp. Range, °F | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Length, ft. | 1-99 | 100-Up | |
300V AC/300V DC | ||||||||||||
24 | 10 | 24/10 | 0° to 175° | 0.25" | Gray | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | Uninsulated Ground Wire | CM, CMG | 00000000 | 00000 | 00000 |
Ribbon Cable
- Use For: Automation, Data, Panel and Equipment (Hook-Up)
- Ultra Flexible
- Temperature Range: 0° to 175° F
- Insulation: PVC Plastic
Often used in electronic prototyping or in the interior of computers, this flat cable is ultra flexible with small-gauge wires so it fits in tight spaces. Unlike standard flat control cable, the wires are bonded together without an overall insulation, so they can be easily separated for installation. Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Continuous-Flex Data Communication Cable
- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, it releases minimal particles into the air. It is CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
Data Communication Cable
- Use For: Data, Interference Shielding
- Flexible
- Outer Insulation: PVC Plastic
Connect computers, CNC machines, and other equipment that requires complex data and signal transmission. This double-shielded cable has both braid and foil for the highest level of protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and motors. This CM-designated cable is flame rated for general purpose applications, such as in-wall installation or use between equipment on shop floors. It’s also rated VW-1 to keep fire from spreading. This cable has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | Temp. Range, °F | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||||
300V AC | |||||||||||||||
24 | 10 | 24/10 | 10 | 12.5 pF | 0° to 165° | 0.31" | CM | Gray | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 00000 | 00000 |
Twisted-Pair Data Communication Cable
- Use For: Data, Interference Shielding
- Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
This cable has twisted pairs of wires that cancel signal interference from multiple transmission lines, as well as foil and braid shielding over the entire cable. It's often used to transmit data in high speed computers near variable-frequency drive motors, where voltage fluctuations and current spikes can distort signals. The industry designation is CM and CMG, so it’s approved for in-wall installation and has flame-resistant insulation. The uninsulated ground wire is not counted in the number of wires.