About Wire and Cable
More
High-Temperature Cable
The insulation on this cable withstands high-heat applications such as ovens and furnaces. The wires are silver or nickel plated for corrosion resistance.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. It has PTFE outer and inner insulation that resists chemicals, oil, abrasion, and moisture.

- Use For: Ovens and Furnaces, Interference Shielding
- Flexible
- Temperature Range: -65° to 390° F
- Insulation: PTFE Plastic
Continuous-Flex Cable


Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
Cable with TPE rubber outer insulation have a protective layer that is more flexible and resists abrasion better than other materials. Halogen-free TPE rubber also stands up to extreme temperatures and chemicals, making it good for use in harsh outdoor environments.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.

- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
24 | 4 | 24/4 | 5 A @ 86° F | 0.22" | 1.65" | Gray | Brown, Green, White, Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 |

- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -30° to 210°
- Inner Insulation: TPE Rubber
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
24 | 4 | 24/4 | 5 A @ 86° F | 0.22" | 5" | Gray | Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 |

- Use For: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
24 | 4 | 24/4 | 4 A @ 86° F | 0.28" | 1.9" | Green | Brown, Green, White, Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Oil-Resistant Continuous-Flex Cable
This cable has an insulation with excellent resistance to oil, so it can be used near motors and equipment that require oil lubrication. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.


- Use For: Automation, Continuous Motion
- Continuous Flex
- Insulation:
300 and 1000V AC: TPE Rubber Inner Insulation
600V AC: PVC Plastic Inner Insulation
See Table for Outer Insulation - Environment:
300 and 1000V AC: Clean Room
600V AC: Not Rated - Specifications Met:
300 and 1000V AC: UL Recognized Component, C-UL Recognized Component, Flame Rated VW-1
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
24 | 4 | 24/4 | 5 A @ 86° F | -30° to 175° | 0.22" | 1.5" | Polyurethane Rubber | Gray | Brown, Green, White, Yellow | ISO Class 1 | 0000000 | 00000 | 00000 |
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
12,000V DC/17,000V AC | |||||||||||||||
24 | 4 | 24/4 | 8 A @ 86° F | 0.27" | 0.09" | 1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Continuous-Flex and -Twist Robotics Cable


- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range:
300V AC, 600V AC: -40° to 175° F
1,000V AC: -10° to 175° F - Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
In addition to handling continuous movement, this cable withstands twisting up to 450° without degrading data or signal transmission. It's often used in welding robots and rotary tables. It’s flame rated VW-1 to meet requirements for preventing the spread of flame based on a timed test with vertically suspended material. The polyurethane rubber insulation resists abrasion and oil.
Use unshielded cable in applications where signal interference is not a concern.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
300V AC | ||||||||||||
24 | 4 | 24/4 | 4 A @ 86° F | 0.24" | 2.88" | Black | Black, Green/Yellow | CSA Certified, UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
For technical drawings and 3-D models, click on a part number.

- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
Continuous-Flex Data Communication Cable

- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, it releases minimal particles into the air. It is CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | OD | Bend Radius | Outer Insulation Color | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire with PVC Plastic Insulation | |||||||||||
300V AC | |||||||||||
24 | 4 | 24/4 | 0.22" | 1.8" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire with TPE Rubber Insulation | |||||||||||
300V AC | |||||||||||
24 | 4 | 24/4 | 0.26" | 1.77" | Blue | ISO Class 1 | CE Marked | 0000000 | 0000 | 0000 |
Data Communication Cable

- Use For: Data, Interference Shielding
- Flexible
- Outer Insulation: PVC Plastic
Connect computers, CNC machines, and other equipment that requires complex data and signal transmission. This double-shielded cable has both braid and foil for the highest level of protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and motors. This CM-designated cable is flame rated for general purpose applications, such as in-wall installation or use between equipment on shop floors. It’s also rated VW-1 to keep fire from spreading. This cable has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | Temp. Range, °F | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||||
300V AC | |||||||||||||||
24 | 4 | 24/4 | 10 | 12.5 pF | 0° to 165° | 0.23" | CM | Gray | Black, Green, Red, White | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 00000 | 00000 |
Twisted-Pair Data Communication Cable

- Use For: Data, Interference Shielding
- Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
This cable has twisted pairs of wires that cancel signal interference from multiple transmission lines, as well as foil and braid shielding over the entire cable. It's often used to transmit data in high speed computers near variable-frequency drive motors, where voltage fluctuations and current spikes can distort signals. The industry designation is CM and CMG, so it’s approved for in-wall installation and has flame-resistant insulation. The uninsulated ground wire is not counted in the number of wires.
Continuous-Flex Ethernet Cable

- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Outer Insulation: TPE Rubber, except Category 6A is Polyurethane Plastic
Inner Insulation: TPE Rubber, except Category 6A is Polyolefin Plastic
Often used in automated applications that require continuous motion such as robotics, this cable sends data between computers, servers, and switches without degrading data transmission. This Ethernet cable is backward compatible so it works in networks that meet the same or a lower category. It is double shielded, which means it has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors. Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Temp. Range, °F | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | ||||||||||||||
5 | 100 MHz | 24 | 4 | 24/4 | -30° to 155° | 0.28" | 2.8" | Purple | Brown, Green, White, Yellow | UL Recognized Component, C-UL Recognized Component, UL 2556 FT1 | 0000000 | 00000 | 00000 |
Industrial Communication-Standard Cable

- Use For:
Flexible: Data, Interference Shielding
Continuous Flex: Data, Interference Shielding, Automation, Continuous Motion - Insulation: See Table
Connect devices such as sensors, programmable logic controllers, and actuators to an automated network. Choose the communication standard that matches your existing network.
Flexible cable bends easily, but is not meant to be in constant motion. Use continuous-flex cable in automated applications that require continuous motion, such as robotics.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Its protective layer resists abrasion, though it contains halogen. It’s also less flexible than cable with TPE rubber insulation. Cable with TPE rubber outer insulation has a halogen-free protective layer that is more flexible and resists abrasion better than other materials. It also stands up to extreme temperatures and chemicals, making it good for use in harsh outdoor environments.
Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Uninsulated ground wires are not counted in the number of wires.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. VW-1 cable is suspended vertically during testing.
Outer Insulation | Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Standard | Transmission Speed | Wire Ga. (No. of Wires) | Temp. Range, °F | OD | Material | Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Flexible | ||||||||||||
Double-Shielded Stranded Wire | ||||||||||||
Modbus | 35 Mbps | 24 (4) | -20° to 175° | 0.34" | PVC Plastic | Gray | Uninsulated Ground Wire | __ | 000000 | 00000 | 00000 | |
Continuous Flex | ||||||||||||
Double-Shielded Stranded Wire | ||||||||||||
CAN-Bus | 1 Mbps | 24 (4) | -30° to 155° | 0.26" | TPE Rubber | Purple | __ | UL 2556 VW-1 | 0000000 | 0000 | 0000 | |