McMaster-Carr logo
    Filter by
    Number of Wires
    Attribute Image
    American Wire Gauge (AWG)
    Industrial Info Snippet
    Attribute Image
    Ethernet Cable Category
    Industrial Info Compare
    Wire Construction
    Industrial Info Snippet
    System of Measurement
    Shield Type
    Outer Jacket Color
    Maximum Temperature
    Wire Material
    Signal Type
    Outer Jacket Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    7 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Ethernet Cable , Shielded.
    Image of Product. Front orientation. Ethernet Cable. Ethernet Cable , Shielded.

    Shielded

    Shielded

    Image of Product. Front orientation. Ethernet Cable. Ethernet Cable , Double Shielded.

    Double Shielded

    Send data between computers, printers, servers, and switches. Ethernet category standards describe the cable’s performance capabilities. Higher category numbers mean faster speeds, superior data transfer, and better signal strength. Category cables are backward compatible, so you can mix and match, but your speed will only be as fast as the lowest-rated cable.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment, such as variable frequency drives or small motors. It has an uninsulated ground wire that is not counted in the number of wires.
    Double Shielded—Double-shielded cable has a layer of braid and foil shielding for the best protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and heavy duty motors.
    CM Cable—CM and CMR cable prevent the spread of flames down the length of the cable. CMR is more flame resistant than CM cable.
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Max. Temp.,
    ° F
    OD
    Cable
    Designation
    Outer Jacket
    Material
    Material
    Color
    Outer Jacket
    Color
    Choose a Length, ft.
    1-499
    500-Up
    Shielded Stranded Wire with Uninsulated Ground Wire
    5e
    10026
    826/8
    1400.22"CM
    PVC
    PolyethyleneBlue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    White
    25
    ,
    50
    ,
    100
    ,
    500
    ,
    1,000
    7734T470000000000
     
    Double-Shielded Stranded Wire
    6A
    50026
    826/8
    1750.27"PVC
    PolyethyleneBlue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    Yellow
    10
    ,
    25
    ,
    50
    ,
    100
    ,
    300
    4232T200000000
     

    Servomotor Continuous-Flex Cable

    Connect servocontrollers and servomotors in automated equipment and on assembly lines. This cable withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion and oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Control Wire—Stranded
    Image of Product. Front orientation. Servo Cable. Servomotor Continuous-Flex Cable, Shielded.
    Image of Attribute. Front orientation. Contains Annotated. Servomotor Continuous-Flex Cable.

    Shielded

    Cable with control wires is also known as feedback cable. It sends and receives signals between a servomotor and a PLC.
    Shielded—Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
    Bend Radius—Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
    No. of
    Wires
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Bend
    Radius
    Outer Jacket
    Material
    Outer Jacket
    Color
    Inner Insulation
    Material
    Inner Insulation Color
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    Shielded—30V AC/ 45V DC
    826
    26/8
    0.7 amp @ 86° F0.25"2.17"Polyurethane Rubber
    GreenPolypropylene
    Black, Blue, Brown, Green, Orange, Purple, Red, Yellow-40 to 175UL Recognized Component
    UL 2556 VW-1
    8815T21
    000000
    000000
    0000000
    0000000
    0000000
     

    Continuous-Flex Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Continuous-Flex Ethernet Cable .
    Often used in automated applications that require continuous motion such as robotics, this cable sends data between computers, servers, and switches without degrading data transmission. This Ethernet cable is backward compatible so it works in networks that meet the same or a lower category. It is double shielded, which means it has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors. Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
    UL 2556 FT1—FT1 cable is suspended vertically during testing.
    UL 2556 FT2—FT2 cable is suspended horizontally during testing.
    Flammability Rating—Flame rated cable meets requirements for preventing the spread of flames based on a timed test.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Temp. Range,
    ° F
    OD
    Bend
    Radius
    Material
    Color
    Material
    Color
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Double-Shielded Stranded Wire
    5e
    10026
    826/8
    -30 to 1550.33"3.3"TPE
    PurpleTPE
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10
    ,
    25
    ,
    50
    ,
    100
    ,
    150
    4250T220000000000
    6
    25026
    826/8
    -30 to 1550.33"3.3"TPE
    PurpleTPE
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10
    ,
    25
    ,
    50
    ,
    100
    ,
    150
    4250T230000000000
    6A
    50026
    826/8
    -40 to 1550.28"4.2"Polyurethane PlasticGreenPolyolefinBlue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    UL Recognized Component, C-UL Recognized Component, CSA Certified
    UL 2556 FT2
    10
    ,
    25
    ,
    50
    ,
    100
    ,
    150
    4250T200000000
     

    High-Voltage Continuous-Flex Flat Power Cable

    Image of Product. Front orientation. Power Cable. High-Voltage Continuous-Flex Flat Power Cable.
    For high-voltage systems with constant motion, this cable flexes without breaking. Its thick silicone rubber jacket insulates against high voltage and resists chemicals, oil, moisture, and UV rays. The jacket also has a low-smoke, zero-halogen (LSZH) design to prevent toxic emissions if there’s a fire.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room Std.
    Choose a Length, ft.
    1-99
    100-Up
    17,000V AC/12,000V DC
     
    Unshielded
    26/8
    6 amp @ 86° F0.9"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9634T2050000000000
     
    back to top