Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
System of Measurement System of Measurement |
---|
|
Use For Use For |
---|
|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Ultra Flexible |
![]() |
Flexible |
Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
![]() | Double Shielded |
Inner Insulation Color Inner Insulation Color |
---|
![]() | Black |
![]() | Green |
![]() | Green/Yellow |
![]() | Red |
![]() | White |
Outer Insulation Color Outer Insulation Color |
---|
![]() | Black |
Wire Type Wire Type |
---|
![]() | |
Wire Material Wire Material |
---|
|
Wire Finish Wire Finish |
---|
|
Inner Insulation Material Inner Insulation Material |
---|
|
Specifications Met Specifications Met |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Cable

Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -55° to 220° F
Yellow: -75° to 220° F - Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
6 | 4 | 6/4 | 45 A @ 86° F | 1.08" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 000000 | 000000 |
Corrosion-Resistant Cable

- Use For: Boats, Motors, Panel and Equipment (Hook-Up), Power Supply
- Flexible
- Temperature Range: -40° to 230° F
- Insulation:
Outer: Chlorinated Polyethylene Plastic
Inner: Polyolefin Plastic
The chlorinated polyethylene insulation resists corrosive chemicals and salt water, and the wires are tin plated for corrosion resistance. This cable also withstands oil and solvents. It’s rated UL 1309 for use as marine shipboard cable.
Armored Corrosion-Resistant Cable

- Use For: Boats, Motors, Panel and Equipment (Hook-Up), Power Supply
- Flexible
- Temperature Range: -40° to 230° F
- Insulation:
Outer: Chlorinated Polyethylene Plastic
Inner: Braided Bronze Armor, Polyolefin Plastic
A braided bronze armor provides excellent protection against abrasion and other damage. The chlorinated polyethylene insulation resists corrosive chemicals and salt water, and the wires are tin plated for corrosion resistance. This cable also withstands oil and solvents. It’s rated UL 1309 for use as marine shipboard cable.
Oil-Resistant Continuous-Flex Cable
This cable has an insulation with excellent resistance to oil, so it can be used near motors and equipment that require oil lubrication. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.


- Use For: Automation, Continuous Motion
- Continuous Flex
- Insulation:
300 and 1000V AC: TPE Rubber Inner Insulation
600V AC: PVC Plastic Inner Insulation
See Table for Outer Insulation - Environment:
300 and 1000V AC: Clean Room
600V AC: Not Rated - Specifications Met:
300 and 1000V AC: UL Recognized Component, C-UL Recognized Component, Flame Rated VW-1
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
1,000V AC | ||||||||||||||
6 | 4 | 6/4 | 92 A @ 86° F | 25° to 155° | 0.83" | 6.23" | PVC Plastic | Black | Black, Green/Yellow | ISO Class 2 | 0000000 | 000000 | 000000 |


- Use For: Shielded: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Insulation:
600V AC: PVC Plastic Inner Insulation
1,000V AC: TPE Rubber Inner Insulation
See Table for Outer Insulaton - Environment:
600V AC: Not Rated
1,000V AC: Clean Room - Specifications Met:
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
1,000V AC: UL Recognized Component, C-UL Recognized Component, Flame-Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
1,000V AC | ||||||||||||||
6 | 4 | 6/4 | 92 A @ 86° F | 25° to 155° | 0.95" | 6.98" | PVC Plastic | Black | Black, Green/Yellow | ISO Class 2 | 0000000 | 000000 | 000000 |
No-Conduit-Required Control Cable


- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands period flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
6 | 4 | 6/4 | 75 A @ 86° F | 0.9" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 000000 | 000000 | |
Double-Shielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
6 | 4 | 6/4 | 75 A @ 86° F | 0.92" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 |
Motor Cable
This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power wires sends electricity to run a motor.
Cable with power and signal wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.
MSHA approved cable meets Mine Safety and Health Administration (MSHA) standards for material quality.

- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic/PVC Plastic
Power Wire | Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double Shielded—1,000V AC/1,500V DC | ||||||||||||
4 | 6 | 6/4 | 55 A @ 86° F | 1" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 000000 | 000000 |

- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: Polyethylene Plastic
Power Wire | Signal Wire | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Double Shielded—1,000V AC/1,000V DC | |||||||||||||||||
4 | 6 | 6/4 | 2 | 14 | 14/2 | 75 A @ 86° F | 1.03" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 |