    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Building Wire

    Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
    Stranded Wire with Polyethylene Outer Jacket
    Image of Product. Front orientation. Building Wire. Building Wire, Stranded Wire with Polyethylene Outer Jacket, XHHW-2 Cable.

    XHHW-2 Cable

    Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Wire with a polyethylene outer jacket resists abrasion and chemicals. It’s more flexible than nylon insulated wire.
    XHHW-2 Cable—XHHW-2 wire is for dry and wet locations where wire may be exposed to dripping or splashing liquid.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    600V AC/600V DC
    14
    7/2215 amp @ 86° F0.14"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T100000000000000000000000000000000
    12
    7/2020 amp @ 86° F0.16"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T2000000000000000000000000000
    10
    7/1830 amp @ 86° F0.18"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T3000000000000000000000000000
    8
    7/1655 amp @ 86° F0.24"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T40000000000000000000000000000
     
    600V AC/1,000V DC
    6
    7/14
    75 amp @ 86° F0.27"-40 to 190BlackXHHW-2
    C-UL Listed, UL Listed
    7715T50000000000000000000000000000
    4
    7/12
    95 amp @ 86° F0.32"-40 to 190BlackXHHW-2
    C-UL Listed, UL Listed
    7715T700000000000000000000000000000
     

    Armored Building Cable

    Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
    Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    MC, XHHW-2 Stranded Wire
    Image of Product. Side1 orientation. Building Cable. Armored Building Cable , XHHW-2 Cable.
    Cable with XHHW-2 wire has a PVC outer jacket over the aluminum armor. You can use it in wet environments where liquid might drip and splash on it. It can also be used for direct burial without a conduit.
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Features
    Hazardous Location Rating
    Specs.
    Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    600V AC/600V DC
    14
    314/3
    15 amp @ 86° F0.64"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T31000000000000000000000000000000000
    12
    312/3
    20 amp @ 86° F0.65"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T320000000000000000000000
    12
    412/4
    20 amp @ 86° F0.68"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T330000000000000000000000000000
    10
    310/3
    30 amp @ 86° F0.7"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T3400000000000000000000000000000
    10
    410/4
    30 amp @ 86° F0.74"Aluminum, PVC
    Cross-Linked PolyethyleneBlack-40 to 190Uninsulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL 15696730T3500000000000000000000000000000
     