McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Number of Wires
    Attribute Image
    Wire Construction
    Industrial Info Compare
    System of Measurement
    Inner Insulation Color
    Maximum Temperature
    Outer Jacket Material
    Wire Material
    Shield Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    28 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Vehicle Wire

    Originally designed to meet the quality standards of the auto industry, this wire withstands high temperatures, flames, and abrasion. You'll often hear it referred to as primary wire in trucks, trailers, forklifts, and other vehicles.
    GPT Stranded Wire
    Image of Product. Front orientation. Vehicle Wire. Vehicle Wire, GPT Cable.
    In protected environments, such as vehicle interiors, GPT wire is the best choice.
    SAE J1128—Unlike other low-voltage wires, this wire meets strict SAE performance requirements.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Temp. Range,
    ° F
    Specs.
    Met
    Lg.,
    ft.
    Choose an Outer Jacket Color
    Each
    25V AC/60V DC
    12
    19/25
    38 amp @ 86° F0.15"PVC
    -10 to 175SAE J112812Black, Blue, Green, Red, White, Yellow6659T2800000
    12
    19/25
    38 amp @ 86° F0.15"PVC
    -10 to 175SAE J1128100Black, Blue, Green, Red, White, Yellow6659T2400000
     
    GXL Stranded Wire
    Image of Product. Front orientation. Vehicle Wire. Vehicle Wire, GXL Cable.
    For wiring exposed to weather and wear and tear, GXL wire is the standard choice, as it balances flexibility and abrasion-resistance.
    Cross-Linked Polyethylene Outer Jacket—For wiring exposed to weather and wear and tear, choose a wire with a cross-linked polyethylene outer jacket.
    SAE J1128—Unlike other low-voltage wires, this wire meets strict SAE performance requirements.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Outer Jacket Material
    Temp. Range,
    ° F
    Specs.
    Met
    Lg.,
    ft.
    Choose an Outer Jacket Color
    Each
    25V AC/60V DC
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5980N313000000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5980N31400000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5980N31500000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5980N316000000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5980N317000000
     

    Abrasion-Resistant Lead Wire

    Run power over rough surfaces—this wire has thick insulation that stands up to wear and tear. It’s flame rated, which means it meets requirements for preventing the spread of fire. Also known as hook-up wire.
    Stranded Wire with FEP Outer Jacket
    Image of Product. Front orientation. Lead Wire. Abrasion-Resistant Lead Wire, Stranded Wire with FEP Outer Jacket.
    Wire with FEP insulation won’t become brittle from chemicals, and it withstands extreme temperatures, from -90° to 390° F.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Choose an Outer
    Jacket Color
    Choose a Length, ft.
    1-499
    500-Up
    600V AC
    10
    105/30
    90 amp @ 86° F0.15"-90 to 390UL Recognized Component
    UL 2556 VW-1
    Black, Red, White10, 25, 50, 100, 5006276T190000000000
     
    Stranded Wire with Silicone Rubber Outer Jacket
    Image of Product. Front orientation. Lead Wire. Abrasion-Resistant Lead Wire, Stranded Wire with Silicone Rubber Outer Jacket.
    Wire with silicone rubber insulation is the most flexible wire we offer. It bends easily around tight turns without cracking.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Choose an Outer
    Jacket Color
    Choose a Length, ft.
    1-499
    500-Up
    600V AC
    16
    26/30
    14 amp @ 86° F0.15"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K220000000000
     

    High-Temperature Power Cable

    Image of Product. Front orientation. Power Cable. High-Temperature Power Cable, Shielded.

    Shielded

    When others can't take the heat, this cable delivers power in ovens, furnaces, steel mills, and foundries. The PTFE jacket won't degrade and weaken as temperatures rise. It also resists abrasion, chemicals, oil, and moisture.
    Shielded—Shielding stops these cables from acting as antennas that emit electromagnetic interference, which could disrupt nearby equipment such as control or data cables.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @ Temp.
    Material
    Color
    Temp.,
    ° F
    Mil. Spec.
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Shielded
    22/2
    4.9 amp @ 86° F
    2.4 amp @ 300° F
    PTFE
    White-65 to 390MIL-W-16878/4 Type E10, 20, 50, 1008219K540000000000
    22/3
    4.9 amp @ 86° F
    2.4 amp @ 300° F
    PTFE
    White-65 to 390MIL-W-16878/4 Type E10, 20, 50, 1008219K5500000000
     

    Building Wire

    Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
    Solid Wire with Nylon Outer Jacket and PVC Inner Insulation
    Image of Product. THHN/THWN Solid Wire. Front orientation. Building Wire. Building Wire, Nylon Outer Jacket, Solid Wire.

    THHN/THWN Solid Wire

    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    Wire with a nylon outer jacket resists oil and water.
    THHN Cable—THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement.
    THWN Cable—THWN and THWN-2 wire can be used in both wet and dry environments.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Shorter Lengths
    Longer Lengths
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose an Outer Jacket Color
    Choose a Length, ft.
    Per
    Ft.
    Lg.,
    ft.
    Each
    600V AC/600V DC
    10
    30 amp @ 86° F0.15"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow25, 50, 100, 2507715T33000005007715T730000000
     

    Machine Tool Wire

    More flexible than standard wire, this wire is often used for internal appliance wiring. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire. Also known as MTW wire, it’s rated UL 1063 for machine tool wiring.
    600V AC/600V DC
    Image of Product. Front orientation. Lead Wire. Machine Tool Wire.
    Metric wire is also known as Harmonized European Wire and meets HAR H07V-K for size (mm²), material, and voltage. It can also be used on North American electrical panels and machines.
    AWG
    Wire Strand
    Count
    Metric Wire
    Size, mm²
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Flexibility
    Cable
    Designation
    Certification
    AWM
    Style
    Choose an Outer
    Jacket Color
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    500 ft.
    Long
    Stranded Wire
    14
    50/0.26 mm²
    2.535 amp @ 86° F0.15"-40 to 220PVCFlexibleMTW
    CSA Certified, HAR Marked H07V-K, UL Recognized Component
    1015Black, Blue, Green/Yellow6513T500000000000000000000000000000000
     

    Riser-Rated Communication and Security System Cable

    This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Riser-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    18
    318/3
    0.15"PVC
    GrayPVC
    Black, Red, White0 to 140CMR, CL3R
    ETL Listed, C-ETL Listed
    8280T370000000000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Riser-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    422/4
    0.15"PVC
    GrayPVC
    Black, Green, Red, White0 to 140Uninsulated Ground WireCMR, CL3R
    ETL Listed, C-ETL Listed
    8233T3200000000000000000000000000000
    18
    218/2
    0.15"PVC
    GrayPVC
    Black, Red0 to 140Uninsulated Ground WireCMR, CL3R
    ETL Listed, C-ETL Listed
    8233T3400000000000000000000000000
     

    Thermostat Cable

    Image of Product. Front orientation. Thermostat Cable.
    Hook up thermostats, air-conditioning units, and other low-voltage equipment. This cable is designated CL2 so it has flame-resistant insulation. The wires are solid so it stays in the shape you bend it.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Solid Wire
     
    150V AC/150V DC
    20
    520/5
    0.15"PVC
    BrownPolyethyleneBlue, Green, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T14000000000000000000000000000000
    18
    418/4
    0.15"PVC
    BrownPolyethyleneBlue, Green, Red, White0 to 140CL2
    ETL Listed
    8278T2300000000000000000000000000
     

    Duct-Rated Communication and Security System Cable

    Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    18
    318/3
    0.15"PVC
    WhitePVC
    Black, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T17000000000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    422/4
    0.15"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T120000000000000000000000000000000
     

    Miniature Continuous-Flex Control Cable

    Image of ProductInUse. Front orientation. Control Cable. Miniature Continuous-Flex Control Cable.
    Image of Product. Front orientation. Control Cable. Miniature Continuous-Flex Control Cable.
    Deliver precise signals through compact areas. This cable is ideal for continuous motion in small, automated equipment, such as the micro gantry in a 3D printer. It will last for millions of flex cycles while reliably transmitting signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    10 ft.
    Long
    25 ft.
    Long
    200V AC
     
    Shielded
    26/6
    2.4 amp @ 86° FPVC
    Black-40 to 2203890N3100000000000000
     

    Grounding Wire

    Ground your electrical system.
    Flexible Grounding Wire
    Image of Product. Front orientation. Grounding Wire. Noninsulated Stranded.

    Noninsulated

    Stranded

    AWG
    OD
    Material
    Specs. Met
    Mil. Spec.
    5 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Noninsulated Stranded
    8
    0.15"CopperASTM B3, ASTM B8Fed. Spec. A-A-595517512K720000000000000000000000000
     

    High-Voltage Lead Wire

    Image of Product. Front orientation. Lead Wire. High-Voltage Lead Wire.
    Use this wire in high-voltage applications, such as in high-power signs and lasers. It’s also known as corona-resistant hook-up wire. Made of silicone rubber, the insulation resists abrasion. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @ Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket
    Color
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Stranded Wire
     
    15,000V DC
    16
    26/30
    14.7 amp @ 86° F0.15"-40 to 300Silicone RubberWhiteUL Listed
    UL 2556 VW-1
    10, 25, 50, 1008296K210000000000
     

    Riser-Rated Fire Alarm Cable

    This FPLR cable is approved for use in vertical shafts and large facilities with multiple levels. It has flame-resistant insulation for use in critical circuits such as fire alarm systems and smoke detectors.
    Unshielded—Use unshielded cable in applications where signal interference is not a concern.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Unshielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Riser-Rated Fire Alarm Cable , Unshielded.
     
    300V AC/300V DC
    18
    418/4
    0.15"PVC
    RedPVC
    Black, Green, Red, Yellow0 to 140FPLR
    ETL Listed
    8435T43000000000000000000000000
     
    Shielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Riser-Rated Fire Alarm Cable , Shielded.
     
    300V AC/300V DC
    18
    218/2
    0.15"PVC
    RedPVC
    Black, Red0 to 140Uninsulated Ground WireFPLR
    ETL Listed
    8435T420000000000000000000
     

    Duct-Rated Fire Alarm Cable

    Image of Product. Front orientation. Fire Alarm Cable. Duct-Rated Fire Alarm Cable , Unshielded.

    Unshielded

    Also known as plenum cable, this FPLP cable has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The insulation is also flame resistant for use in critical circuits such as fire alarm systems and smoke detectors.
    Unshielded—Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Unshielded Solid Wire
     
    300V AC/300V DC
    18
    218/2
    0.15"PVC
    RedPVC
    Black, Red0 to 165FPLP
    UL Listed
    8435T210000000000000000000000000000000
     

    Vehicle Wire Assortments

    Image of Product. Front orientation. Vehicle Wire. Vehicle Wire Assortments.
    Keep spools of vehicle wire in multiple colors on hand.
    GXL Cable—GXL cable has a cross-linked polyethylene outer jacket that withstands higher temperatures and has more abrasion resistance than PVC outer jackets. GXL cable has thick walls, making it suitable for engine compartments.
    SAE J1128—They meet SAE J1128 for low-voltage wiring in trucks, boats, trailers, and other vehicles.
    No. of
    Spools
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket Color
    Lg.,
    ft.
    Specs.
    Met
    Each
    GXL Stranded Wire with Cross-Linked Polyethylene Outer Jacket
     
    25V AC/60V DC
    512
    19/25
    14 amp @ 86° F0.15"-40 to 255Black, Blue, Green, Red, White25SAE J11283038N270000000
     
    back to top