McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Wire Construction
    Industrial Info Compare
    Number of Wires
    Attribute Image
    System of Measurement
    AWM Style
    Wire Material
    Material
    Outer Jacket Material
    Industrial Info Compare
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    64 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Lead Wire

    Also known as hook-up wire, this wire is primarily used for wiring electrical panels, lighting, and plant floor equipment. It meets UL 1007, UL 1015, or UL 1569 for appliance wiring.
    Stranded Wire—300V AC
    Image of Product. Front orientation. Stranded Wire. Lead Wire.
    Stranded wire is flexible, so it’s pliable enough to be pulled around corners. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    28
    7/36
    4 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T310000000000000000000000000000
    26
    7/34
    5 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T1100000000000000000000000
    24
    7/32
    7 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T1200000000000000000000000
    22
    7/30
    10 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T1300000000000000000000000
    20
    10/30
    13 amp @ 86° F0.07"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T1400000000000000000000000
    18
    16/30
    18 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T15000000000000000000000000
    16
    26/30
    24 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T160000000000000000000000000
    14
    41/30
    33 amp @ 86° F0.11"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T1700000000000000000000000000
    12
    65/30
    45 amp @ 86° F0.12"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T18000000000000000000000000000
    10
    105/30
    58 amp @ 86° F0.16"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8054T190000000000000000000000000000
    Stranded Wire—600V AC
    Image of Product. Front orientation. Stranded Wire. Lead Wire.
    Stranded wire is flexible, so it’s pliable enough to be pulled around corners. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM
    Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    26
    7/34
    5 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T210000000000000000000000000000
    24
    7/32
    7 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T2200000000000000000000000
    22
    7/30
    10 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T2300000000000000000000000
    20
    10/30
    13 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T2400000000000000000000000
    18
    16/30
    18 amp @ 86° F0.11"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T25000000000000000000000000
    16
    26/30
    24 amp @ 86° F0.12"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T260000000000000000000000000
    14
    41/30
    33 amp @ 86° F0.14"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T2700000000000000000000000000
    12
    65/30
    45 amp @ 86° F0.16"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T28000000000000000000000000000
    10
    105/30
    58 amp @ 86° F0.18"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8054T290000000000000000000000000000
    Solid Wire—300V AC
    Image of Product. Front orientation. Solid Wire. Lead Wire.
    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    26
    5 amp @ 86° F0.05"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8251T9000000000000000000000000000
    24
    7 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8251T100000000000000000000000
    22
    10 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8251T200000000000000000000000
    20
    13 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8251T300000000000000000000000
    18
    18 amp @ 86° F0.07"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Purple8251T4000000000000000000000000
    Solid Wire—600V AC
    Image of Product. Front orientation. Solid Wire. Lead Wire.
    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM
    Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    18
    18 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Purple8428T400000000000000000000000000000

    Mil. Spec. Lead Wire

    Image of Product. Front orientation. Lead Wire. Mil. Spec. Lead Wire.
    This wire meets stringent military specifications for material quality. It’s also known as hook-up wire.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Mil. Spec.
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    Stranded Wire
     
    1,000V AC
    22
    7/30
    8 amp @ 86° F0.06"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWPurple6981T20000000000000000000000000000
    20
    10/30
    10 amp @ 86° F0.07"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWPurple6981T300000000000000000000000
    18
    16/30
    15 amp @ 86° F0.08"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWPurple6981T4000000000000000000000000
    16
    19/29
    19 amp @ 86° F0.1"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWPurple6981T500000000000000000000000000
    14
    19/27
    27 amp @ 86° F0.11"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWPurple6981T600000000000000000000000000
     

    Industrial CAN-Bus Cable

    Image of Product. Front orientation. CAN-Bus Cable. Industrial CAN-Bus Cable.
    Connect devices such as sensors, PLCs, and actuators to a CAN-Bus network.
    Use this continuous-flex cable in automated applications that require continuous motion, such as robotics. This double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
    This flame-rated cable meets requirements for preventing the spread of flames based on a timed test. VW-1 cable is suspended vertically during testing.
    PVC Outer Jacket—Choose cable with PVC outer jacket for general purpose indoor applications. Its protective layer resists abrasion, though it contains halogen. It’s also less flexible than cable with TPE jacket.
    TPE Outer Jacket—Cable with TPE outer jacket has a protective layer that is more flexible and resists abrasion better than other materials. It also stands up to extreme temperatures and chemicals, making it good for use in harsh outdoor environments.
    Outer
    Jacket
    Per Ft.
    Transmission
    Speed, Mbit/s
    AWG (No.
    of Wires)
    Temp. Range,
    ° F
    OD
    Material
    Color
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Continuous Flex
     
    Double-Shielded Stranded Wire
    124 (4)-30 to 1550.26"TPE
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T210000000000
    124 (4)45 to 1550.28"PVC
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T2600000000
    120 (2)-30 to 1550.31"TPE
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T2200000000
    120 (2)45 to 1550.33"PVC
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T2700000000
    120 (4)-30 to 1550.31"TPE
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T2300000000
    120 (4)45 to 1550.33"PVC
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T2800000000
     

    Ribbon Cable

    Image of Product. Front orientation. Ribbon Cable.
    Often used in electronic prototyping or in the interior of computers, this flat cable is ultra flexible with small-gauge wires so it fits in tight spaces. Unlike standard flat control cable, the wires are bonded together without an overall insulation, so they can be easily separated for installation.
    UL 2556 VW-1— Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Outer
    Jacket
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    Wd.
    Thk.
    Material
    Color
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    Stranded Wire
     
    150V AC
    26
    1026/10
    1 amp @ 86° F0.39"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N210000000000000
    26
    1526/15
    1 amp @ 86° F0.59"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N2200000000000
    24
    1024/10
    2.1 amp @ 86° F0.44"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N23000000000000
    24
    1524/15
    2.1 amp @ 86° F0.66"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N24000000000000
    22
    1022/10
    3.1 amp @ 86° F0.51"0.05"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N25000000000000
    22
    1522/15
    3.1 amp @ 86° F0.77"0.05"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N26000000000000
     

    Industrial Profibus Cable

    Image of Product. Front orientation. Profibus Cable. Industrial Profibus Cable.
    Connect devices such as sensors, PLCs, and actuators to a Profibus network.
    This double-shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
    Flexible—Flexible cable bends easily, but is not meant to be in constant motion.
    Continuous Flex—Use continuous-flex cable in automated applications that require continuous motion, such as robotics.
    PVC Outer Jacket—Choose cable with PVC outer jacket for general purpose indoor applications. Its protective layer resists abrasion, though it contains halogen. It’s also less flexible than cable with TPE jacket.
    TPE Outer Jacket—Cable with TPE outer jacket has a protective layer that is more flexible and resists abrasion better than other materials. It also stands up to extreme temperatures and chemicals, making it good for use in harsh outdoor environments.
    UL 2556 FT4—Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT4 cable is mounted to a vertical tray during testing.
    UL 2556 VW-1—Flame rated cable meets requirements for preventing the spread of flames based on a timed test. VW-1 cable is suspended vertically during testing.
    Outer
    Jacket
    Per Ft.
    Transmission
    Speed, Mbit/s
    AWG (No.
    of Wires)
    Temp. Range,
    ° F
    OD
    Material
    Color
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Flexible
     
    Double-Shielded Solid Wire
    1222 (2)-20 to 1650.32"PVC
    PurpleUL 2556 FT4
    10, 25, 50, 100, 2508463T10000000000
     
    Continuous Flex
     
    Double-Shielded Stranded Wire
    1224 (2)-30 to 1550.33"TPE
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508463T200000000
    1224 (2)45 to 1550.33"PVC
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T2500000000
     

    Continuous-Flex Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Continuous-Flex Ethernet Cable .
    Often used in automated applications that require continuous motion such as robotics, this cable sends data between computers, servers, and switches without degrading data transmission. This Ethernet cable is backward compatible so it works in networks that meet the same or a lower category. It is double shielded, which means it has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors. Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
    UL 2556 FT1—FT1 cable is suspended vertically during testing.
    Flammability Rating—Flame rated cable meets requirements for preventing the spread of flames based on a timed test.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Temp. Range,
    ° F
    OD
    Bend
    Radius
    Material
    Color
    Material
    Color
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Double-Shielded Stranded Wire
    5
    10024
    424/4
    -30 to 1550.28"2.8"TPE
    PurpleTPE
    Brown
    Green
    White
    Yellow
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 100, 1504250T210000000000
    5e
    10026
    826/8
    -30 to 1550.33"3.3"TPE
    PurpleTPE
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 100, 1504250T2200000000
    6
    25026
    826/8
    -30 to 1550.33"3.3"TPE
    PurpleTPE
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 100, 1504250T230000000000
     

    Building Cable

    Image of Product. Front orientation. Building Cable. Building Cable , NM-B Cable, THHN Cable.

    THHN Cable

    NM-B Cable

    Rated for in-wall installation, this cable carries power to wall outlets. Also known as branch circuit wire, it can be used without conduit. It has solid THHN building wires, so the cable will stay in the shape you bend it. The uninsulated ground wire is not counted in the number of wires.
    NM-B Cable—NM-B cable is for dry locations where moisture is not a concern, and often run through walls, ceilings, and concrete blocks.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    Wd.
    Thk.
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Certification
    Specs.
    Met
    Choose a Length, ft.
    1-249
    250-Up
    NM-B, THHN Solid Wire
     
    600V AC
    12
    312/3
    20 amp @ 86° F0.52"0.19"PVC
    PurplePVC
    Black, Red, White10 to 190Uninsulated Ground WireUL Listed
    UL 71910, 25, 50, 100, 25069935K650000000000
     

    Circuit Board Cords

    Make connections in circuit boards with these short lengths of terminated wire. Length does not include the machine pins.
    Machine-Pin Terminal Connection—Insert a male machine pin into the holes on a solderless circuit board, or into a female machine pin.
    Outer Jacket Color—Cords with multiple colors are assortments that contains one cord in each color.
    Lg.
    Outer
    Jacket
    AWG
    Wire Strand
    Count
    Pin Dia./For
    Pin Dia.
    Temp. Range,
    ° F
    Inch
    Metric,
    cm
    Material
    Color
    Pkg.
    Qty.
    Pkg.
    Stranded Wire
     
    Image of Product. Front orientation. Circuit Board Cords. Circuit Board Cords, Female Machine-Pin Terminal × Female Machine-Pin Terminal.
    Female Machine-Pin Terminal × Female Machine-Pin Terminal
    24
    11/34
    0.025" × 0.025"-40 to 1751.97"5PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N3900000
    24
    11/34
    0.025" × 0.025"-40 to 1753.94"10PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N410000
    24
    11/34
    0.025" × 0.025"-40 to 1757.87"20PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N420000
    24
    11/34
    0.025" × 0.025"-40 to 1757.87"20PVC
    Purple103104N1600000
    24
    11/34
    0.025" × 0.025"-40 to 17511.81"30PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N430000
     
    Image of Product. Front orientation. Circuit Board Cords. Circuit Board Cords, Male Machine-Pin Terminal × Female Machine-Pin Terminal.
    Male Machine-Pin Terminal × Female Machine-Pin Terminal
    24
    11/34
    0.025" × 0.025"-40 to 1751.97"5PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N350000
    24
    11/34
    0.025" × 0.025"-40 to 1753.94"10PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N360000
    24
    11/34
    0.025" × 0.025"-40 to 1757.87"20PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N370000
    24
    11/34
    0.025" × 0.025"-40 to 17511.81"30PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N380000
     
    Image of Product. Front orientation. Circuit Board Cords. Circuit Board Cords, Male Machine-Pin Terminal × Male Machine-Pin Terminal.
    Male Machine-Pin Terminal × Male Machine-Pin Terminal
    24
    11/34
    0.025" × 0.025"-40 to 1751.97"5PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N310000
    24
    11/34
    0.025" × 0.025"-40 to 1753.94"10PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N320000
    24
    11/34
    0.025" × 0.025"-40 to 1757.87"20PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N330000
    24
    11/34
    0.025" × 0.025"-40 to 17511.81"30PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N340000
     

    Industrial Communication-Standard Cable

    Image of Product. Front orientation. DeviceNet Cable. Industrial Communication-Standard Cable.
    Connect devices such as sensors, PLCs, and actuators to DeviceNet network.
    Continuous Flex—Use continuous-flex cable in automated applications that require continuous motion, such as robotics. Use For: Data, Interference Shielding, Automation, Continuous Motion.
    Double Shielded—Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
    TPE Outer Jacket—Cable with TPE outer jacket has a protective layer that is more flexible and resists abrasion better than other materials. It also stands up to extreme temperatures and chemicals, making it good for use in harsh outdoor environments.
    UL 2556 VW-1—Flame rated cable meets requirements for preventing the spread of flames based on a timed test. VW-1 cable is suspended vertically during testing.
    Outer
    Jacket
    Per Ft.
    Communication
    Interface
    Transmission
    Speed, kbit/s
    Wire Ga. (No. of Wires)
    Temp. Range,
    ° F
    OD
    Material
    Color
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Continuous Flex
     
    Double Shielded Stranded Wire
    DeviceNet125 (4 ) total: 24 (2), 22 (2)-30 to 1550.3"TPE
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T40000000000
    DeviceNet125 (4 ) total: 18 (2), 15 (2)-30 to 1550.45"TPE
    PurpleUL 2556 VW-1
    10, 25, 50, 100, 2508097T30000000000
     
    back to top