    150 Products
    About Pipe and Fittings
    industrial info icon

    Measure your pipe and fittings to identify their pipe size, thread size, schedule, and thread type. Then, find compatible components.

    Thick-Wall Plastic Pipe Fittings for Water

    Connect these fittings to Schedule 80 pipe. With thicker, stronger walls than standard-wall fittings, they can handle heavy duty supply applications, such as water processing, wastewater treatment, and irrigation. Fittings are plastic for good corrosion resistance. They meet ASTM specifications and testing requirements for material quality.
    To prevent leaks in threaded connections, apply a sealant to the male threads. Threaded connections can be taken apart as needed for maintenance and repair. For metal threads, use PTFE tape. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
    Warning: Never use plastic pipe fittings, flanges, and pipe with compressed air or gas.
    Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
    Saddle Tap Tees with Gasket
    Image of Product. Front orientation. Pipe and Fittings. Thick-Wall Plastic Pipe Fittings for Water, Saddle Tap Tees with Gasket, Cement Socket Female × Clamp On.

    Cement Socket

    Female × Clamp

    On

    Saddle-tap tee adapters allow you to create additional outlets and connections in metal or plastic pipe. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole so the gasket and lip are fully engaged and secure with the included nuts, bolts, and washers.
    Cement-Socket Fitting Connection—Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
    NSF/ANSI 61—To adhere to safety standards for drinking water systems, use pipe that meets NSF/ANSI 61.
    Pipe Size
    (A)
    For Pipe
    Size (B)
    For Pipe
    OD (B)
    For Hole
    Dia.
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Food Industry
    Std.
    Each
    Cement Socket Female × Clamp On
    1/2
    2
    2 3/8"3/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K14000000
    1/2
    3
    3 1/2"7/8"80
    PVCDark Gray185 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K1900000
    1/2
    4
    4 1/2"1 1/8"80
    PVCDark Gray160 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K4200000
    3/4
    2
    2 3/8"7/8"80
    PVCDark Gray345 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K1500000
    3/4
    3
    3 1/2"1 1/8"80
    PVCDark Gray345 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K2600000
    3/4
    4
    4 1/2"1 1/8"80
    PVCDark Gray345 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K4300000
    1
    2
    2 3/8"1 1/8"80
    PVCDark Gray315 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K1300000
    1
    3
    3 1/2"2 1/4"80
    PVCDark Gray315 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K2900000
    1
    4
    4 1/2"1 1/8"80
    PVCDark Gray315 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K4400000
    1
    6
    6 5/8"1 1/8"80
    PVCDark Gray315 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K69000000
    1 1/2
    3
    3 1/2"2 1/4"80
    PVCDark Gray235 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K3500000
    1 1/2
    4
    4 1/2"1 3/4"80
    PVCDark Gray235 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K4500000
    2
    3
    3 1/2"1 1/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K3800000
    2
    4
    4 1/2"2 1/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K4600000
    2
    6
    6 5/8"2 1/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K37000000
    3
    4
    4 1/2"3"80
    PVCDark Gray185 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K31000000
    3
    6
    6 5/8"3"80
    PVCDark Gray185 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K39000000
     
    Saddle Tap Tees with Collar and Gasket
    Image of Product. Female x Clamp On. Front orientation. Pipe and Fittings. Thick-Wall Plastic Pipe Fittings for Water, Saddle Tap Tees with Collar and Gasket, Clamp-On Fitting Connection, Threaded Fitting Connection, Female.

    Female x Clamp On

    Saddle-tap tee adapters allow you to create additional outlets and connections in metal or plastic pipe. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole so the gasket and lip are fully engaged and secure with the included nuts, bolts, and washers.
    Fittings with collar have a stainless steel reinforcement on the female threads to prevent the threads from cracking.
    NSF/ANSI 61—To adhere to safety standards for drinking water systems, use pipe that meets NSF/ANSI 61.
    Pipe Size
    (A)
    For Pipe
    Size (B)
    For Pipe
    OD (B)
    For Hole
    Dia.
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Food Industry
    Std.
    Each
    NPT Female × Clamp On
    1/2
    2
    2 3/8"3/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K51000000
    1/2
    3
    3 1/2"7/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K5600000
    1/2
    4
    4 1/2"1 1/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K63000000
    3/4
    2
    2 3/8"7/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K5200000
    3/4
    3
    3 1/2"7/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K5700000
    3/4
    4
    4 1/2"1 1/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K64000000
    1
    2
    2 3/8"1 1/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K5300000
    1
    3
    3 1/2"1 1/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K5800000
    1
    4
    4 1/2"1 1/8"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K65000000
    1
    6
    6 5/8"1 1/8"80
    PVCDark Gray315 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K74000000
    1 1/2
    3
    3 1/2"2 1/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K6100000
    1 1/2
    4
    4 1/2"1 3/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K67000000
    2
    3
    3 1/2"2 1/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K6200000
    2
    4
    4 1/2"2 1/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K68000000
    2
    6
    6 5/8"2 1/4"80
    PVCDark Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K82000000
    3
    4
    4 1/2"3"80
    PVCDark Gray185 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K71000000
    3
    6
    6 5/8"3"80
    PVCDark Gray185 psi @ 72° FEPDM
    NSF/ANSI 61
    4849K83000000
     

    Standard-Wall Plastic Pipe Fittings for Water

    Connect these fittings to Schedule 40 plastic pipe–they are the industry standard for residential and commercial low-pressure plumbing and water supply applications. They are plastic for good corrosion resistance.
    To prevent leaks in threaded connections, apply a sealant to the male threads. Threaded connections can be taken apart as needed for maintenance and repair. For metal threads, use PTFE tape. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
    Warning: Never use plastic pipe fittings, flanges, and pipe with compressed air or gas.
    Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
    Saddle Tap Tees with Gasket
    Image of Product. Female × Clamp On. Front orientation. Pipe and Fittings. Standard-Wall Plastic Pipe Fittings for Water, Saddle Tap Tees with Gasket, Cement Socket Female × Clamp On.

    Female × Clamp On

    Saddle-tap tee adapters allow you to create additional outlets and connections in metal or plastic pipe. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole so the gasket and lip are fully engaged and secure with the included nuts, bolts, and washers.
    Cement-Socket Fitting Connection—Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
    NSF/ANSI 61—To adhere to safety standards for drinking water systems, use pipe that meets NSF/ANSI 61.
    Pipe Size
    (A)
    For Pipe
    Size (B)
    For Pipe
    OD (B)
    For Hole
    Dia.
    OD
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Food Industry
    Std.
    Each
    Cement Socket Female × Clamp On
    1/2
    2
    2 3/8"3/4"27/32"40
    PVCWhite300 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K11000000
    1/2
    3
    3 1/2"7/8"27/32"40
    PVCWhite300 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K1600000
    1/2
    4
    4 1/2"1 1/8"27/32"40
    PVCWhite300 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K2300000
    3/4
    2
    2 3/8"7/8"1 1/16"40
    PVCWhite240 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K4300000
    3/4
    3
    3 1/2"7/8"1 1/16"40
    PVCWhite240 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K1700000
    3/4
    4
    4 1/2"1 1/8"1 1/16"40
    PVCWhite240 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K24000000
    1
    2
    2 3/8"1 1/8"1 5/16"40
    PVCWhite225 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K4400000
    1
    3
    3 1/2"1 1/8"1 5/16"40
    PVCWhite225 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K1800000
    1
    4
    4 1/2"1 1/8"1 5/16"40
    PVCWhite225 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K25000000
    1
    6
    6 5/8"1 1/8"1 5/16"40
    PVCWhite225 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K42000000
    1 1/2
    3
    3 1/2"2 1/4"1 29/32"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K2100000
    1 1/2
    4
    4 1/2"1 3/4"1 29/32"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K27000000
    2
    3
    3 1/2"2 1/4"2 3/8"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K2200000
    2
    4
    4 1/2"2 1/4"2 3/8"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K28000000
    2
    6
    6 5/8"2 1/4"2 3/8"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K82000000
    3
    4
    4 1/2"3"3 1/2"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K31000000
     
    Saddle Tap Tees with Collar and Gasket
    Image of Product. Female × Clamp On. Front orientation. Pipe and Fittings. Standard-Wall Plastic Pipe Fittings for Water, Saddle Tap Tees with Collar and Gasket, Clamp-On Fitting Connection, Threaded Fitting Connection, Female.

    Female × Clamp On

    Saddle-tap tee adapters allow you to create additional outlets and connections in metal or plastic pipe. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole so the gasket and lip are fully engaged and secure with the included nuts, bolts, and washers.
    Fittings with collar have a stainless steel reinforcement on the female threads to prevent the threads from cracking.
    NSF/ANSI 61—To adhere to safety standards for drinking water systems, use pipe that meets NSF/ANSI 61.
    Pipe Size
    (A)
    For Pipe
    Size (B)
    For Pipe
    OD (B)
    For Hole
    Dia.
    OD
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Food Industry
    Std.
    Each
    NPT Female × Clamp On
    1/2
    2
    2 3/8"3/4"27/32"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K51000000
    1/2
    3
    3 1/2"7/8"27/32"40
    PVCWhite300 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K56000000
    1/2
    4
    4 1/2"1 1/8"27/32"40
    PVCWhite300 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K63000000
    3/4
    2
    2 3/8"7/8"1 3/64"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K5200000
    3/4
    3
    3 1/2"7/8"1 1/16"40
    PVCWhite240 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K57000000
    3/4
    4
    4 1/2"1 1/8"1 3/64"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K64000000
    1
    2
    2 3/8"1 1/8"1 5/16"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K5300000
    1
    3
    3 1/2"1 1/8"1 5/16"40
    PVCWhite225 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K58000000
    1
    4
    4 1/2"1 1/8"1 5/16"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K65000000
    1
    6
    1 5/8"1 1/8"1 5/16"40
    PVCWhite225 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K45000000
    1 1/2
    3
    3 1/2"2 1/4"1 29/32"40
    PVCWhite165 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K61000000
    1 1/2
    4
    4 1/2"1 3/4"1 29/32"40
    PVCWhite165 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K67000000
    2
    3
    3 1/2"2 1/4"2 3/8"40
    PVCWhite140 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K4600000
    2
    4
    4 1/2"2"2 3/8"40
    PVCWhite140 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K68000000
    2
    6
    6 5/8"2 1/4"2 3/8"40
    PVCWhite200 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K85000000
    3
    4
    4 1/2"3"3 1/2"40
    PVCWhite130 psi @ 72° FEPDM
    NSF/ANSI 61
    4763K71000000
     
    Tee Outlets
    Image of Product. Female × Cement Socket. Front orientation. Pipe and Fittings. Standard-Wall Plastic Pipe Fittings for Water, Tee Outlets, Threaded Fitting Connection, Female, Cement-Socket Fitting Connection.

    Female × Cement

    Socket

    Tee outlets allow you to create additional outlets and connections in plastic pipe. Use a PVC primer and cement to secure the tee outlet into position, then drill a hole through the fitting and pipe. They are also known as branch connectors.
    Cement-Socket Fitting Connection—Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
    NSF/ANSI 61—To adhere to safety standards for drinking water systems, use pipe that meets NSF/ANSI 61.
    Pipe Size
    (A)
    For Pipe
    Size (B)
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Food Industry
    Std.
    Each
    NPT Female × Cement Socket
    1/8
    1/2
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K11800000
    1/8
    3/4
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K1190000
    1/2
    1/2
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K1160000
    1/2
    3/4
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K1050000
    1/2
    1
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K1060000
    3/4
    3/4
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K1040000
    3/4
    1
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K1070000
    1
    1
    40
    PVCWhiteNot RatedNSF/ANSI 61
    4880K1170000
     

    Drain, Waste, and Vent PVC Clamp-On Pipe Fittings for Water

    To make installing and maintaining systems easy, these connectors come with clamps that form a strong seal on pipe and fittings once tightened.
    Warning: Never use plastic pipe fittings, flanges, and pipe with compressed air or gas.
    Saddle Tap Tees
    Image of Product. Front orientation. Contains Annotated. Pipe and Fittings. Drain, Waste, and Vent PVC Clamp-On Pipe Fittings for Water, Saddle Tap Tees, Clamp On × Clamp On.

    Clamp On × Clamp On

    Saddle-tap adapters allow you to tap into an existing pipeline. They have wraparound clamps that provide nearly 360° contact with pipe; as the clamps are tightened, pressure is uniformly distributed around the pipe for maximum support. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole and tighten the clamps.
    For
    Pipe Size
    (A)
    (B)
    For Hole
    Dia.
    Material
    Max. Pressure
    @ Temp.
    Clamp Material
    Each
    Clamp On × Clamp On
    4
    6 to 124 1/8"PVCNot Rated300 Series Stainless Steel48545K15000000
    6
    6 to 125 1/2"PVCNot Rated300 Series Stainless Steel48545K17000000
     
    Saddle Tap Wyes
    Image of Product. Front orientation. Contains Annotated. Pipe and Fittings. Drain, Waste, and Vent PVC Clamp-On Pipe Fittings for Water, Saddle Tap Wyes, Clamp On × Clamp On.

    Clamp On × Clamp On

    Saddle-tap adapters allow you to tap into an existing pipeline. They have wraparound clamps that provide nearly 360° contact with pipe; as the clamps are tightened, pressure is uniformly distributed around the pipe for maximum support. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole and tighten the clamps.
    For
    Pipe Size
    (A)
    (B)
    For Hole
    Dia.
    Material
    Max. Pressure
    @ Temp.
    Clamp Material
    Each
    Clamp On × Clamp On
    4
    6 to 124 1/8"PVCNot Rated300 Series Stainless Steel48545K190000000
    6
    6 to 125 1/2"PVCNot Rated300 Series Stainless Steel48545K21000000
     

    CPVC Pipe Fittings for Chemicals

    Made of CPVC, these fittings withstand salt solutions, acids, and other harsh substances. They have thick, strong walls to handle heavy duty industrial plumbing and water supply applications, such as water processing and wastewater treatment. These fittings are comparable to Corzan. Some meet ASTM D1784 specifications and testing requirements for material quality.
    To prevent leaks in threaded connections, apply a sealant to the male threads. Threaded connections can be taken apart as needed for maintenance and repair. For metal threads, use PTFE tape. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
    Warning: Never use plastic pipe fittings, flanges, and pipe with compressed air or gas.
    Saddle Tap Tees with Gasket
    Image of Product. NPT Female × Clamp On. Front orientation. Pipe and Fittings. CPVC Pipe Fittings for Chemicals, Saddle Tap Tees with Gasket, Clamp-On Fitting Connection, Threaded Fitting Connection, Female.

    NPT Female ×

    Clamp On

    Saddle-tap tees allow you to create additional outlets and connections in metal or plastic pipe. They clamp on for an easy way to install and maintain systems.
    80 Pipe Schedule—Schedule 80 fittings have thick, strong walls for heavy duty, industrial applications.
    NSF/ANSI 61—To adhere to safety standards for drinking water systems, use pipe that meets NSF/ANSI 61.
    Pipe Size
    (A)
    For Pipe
    Size (B)
    For Pipe
    OD (B)
    For Hole
    Dia.
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Food Industry
    Std.
    Each
    NPT Female × Clamp On
    1/2
    2
    2 3/8"3/4"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K442000000
    1/2
    3
    3 1/2"7/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K44500000
    1/2
    4
    4 1/2"1 1/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K449000000
    3/4
    2
    2 3/8"7/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K44300000
    3/4
    3
    3 1/2"7/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K44600000
    3/4
    4
    4 1/2"1 1/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K451000000
    1
    2
    2 3/8"1 1/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K44400000
    1
    3
    3 1/2"1 1/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K44700000
    1
    4
    4 1/2"1 1/8"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K452000000
    1 1/2
    3
    3 1/2"2 1/4"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K44800000
    1 1/2
    4
    4 1/2"1 3/4"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K453000000
    2
    4
    4 1/2"2 1/4"80
    CPVCLight Gray230 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K454000000
    2
    6
    6 5/8"2 1/4"80
    CPVCLight Gray200 psi @ 72° FEPDM
    NSF/ANSI 61
    4589K455000000
     

    Easy-Access CPVC Pipe Fittings for Chemicals

    Image of System. Front orientation. Exploded view. Pipe and Fittings. Easy-Access CPVC Pipe Fittings for Chemicals.
    Also known as Victaulic fittings, these have grooved ends that connect to pipe with a clamp, so you can access your chemical process line for routine maintenance. Fittings are CPVC, which has excellent chemical resistance to withstand a variety of salt solutions, acids, and other harsh substances. They are comparable to Corzan. Fittings meet ASTM D1784 specifications and testing requirements for material quality.
    Warning: Never use plastic pipe fittings, flanges, and pipe with compressed air or gas.
    Clamp Connectors with Gasket
    Image of Product. Front orientation. Pipe and Fittings. Easy-Access CPVC Pipe Fittings for Chemicals, Clamp Connectors with Gasket, Grooved-End Clamp-On Female.

    Grooved-End

    Clamp-On Female

    Clamp connectors let you connect CPVC grooved-end pipe fittings and pipe.
    For Pipe
    Size
    For Pipe
    OD
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Each
    Grooved-End Clamp-On Female
    2
    2 3/8"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N27000000
    3
    3 1/2"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N2800000
    4
    4 1/2"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N29000000
     
    Clamp Adapters with Gasket
    Image of Product. Front orientation. Pipe and Fittings. Easy-Access CPVC Pipe Fittings for Chemicals, Clamp Adapters with Gasket, Grooved-End Clamp-On Female × Grooved-End Clamp-On Female.

    Grooved-End

    Clamp-On

    Female ×

    Grooved-End

    Clamp-On Female

    Clamp adapters let you connect CPVC grooved-end pipe fittings and pipe to metal grooved-end pipe fittings and pipe.
    For
    Pipe Size
    For
    Pipe OD
    (A)
    (B)
    (A)
    (B)
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Each
    Grooved-End Clamp-On Female × Grooved-End Clamp-On Female
    3
    3
    3 1/2"3 1/2"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N31000000
    4
    4
    4 1/2"4 1/2"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N32000000
     
    Clamp Reducers with Gasket
    Image of Product. Front orientation. Pipe and Fittings. Easy-Access CPVC Pipe Fittings for Chemicals, Clamp Reducers with Gasket, Grooved-End Clamp-On Female × Grooved-End Clamp-On Female.

    Grooved-End Clamp-On

    Female × Grooved-End

    Clamp-On Female

    Clamp reducers allow you to connect CPVC grooved-end pipe fittings and pipe and transition from a larger pipe size to a smaller pipe size.
    For
    Pipe Size
    For
    Pipe OD
    (A)
    (B)
    (A)
    (B)
    Material
    Color
    Max. Pressure
    @ Temp.
    Gasket
    Material
    Each
    Grooved-End Clamp-On Female × Grooved-End Clamp-On Female
    3
    2
    3 1/2"2 3/8"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N33000000
    4
    2
    4 1/2"2 3/8"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N35000000
    4
    3
    4 1/2"3 1/2"Enamel-Coated IronOrange300 psi @ 72° FEPDM
    2663N34000000
     

    Pivoting Loop Pipe Hangers

    Image of Product. Front orientation. Contains Annotated. Pipe Hangers. Pivoting Loop Pipe Hangers, Rotate.

    Rotate

    Secure pipe overhead and allow it to tilt or rotate as needed. These pipe hangers reduce stress on joints and keep pipe aligned, even when it shifts. Attach these hangers to beams or ceilings with threaded rod.
    360° Rotation—Rotate to allow movement and flexibility when pipes need to be connected at non-standard angles and when working in tight spaces.
    PVC-Coated Steel—Prevent wear from metal-to-metal contact due to movement or thermal expansion.
    ID
    Inch
    Metric,
    mm
    For Pipe
    Size
    For Copper
    Tube Size
    For Thread
    Size
    Wt. Cap.,
    lb.
    Pkg.
    Qty.
    Pkg.
    360° Rotation
     
    PVC-Coated Steel
    13/16"211/2
    5/8
    3/8"-16
    61013064T41000000
    1 1/16"273/4
    3/8"-16
    61013064T4200000
    1 5/16"331
    3/8"-16
    61013064T4300000
    1 11/16"431 1/4
    1 1/2
    3/8"-16
    61013064T4400000
    1 7/8"481 1/2
    3/8"-16
    61013064T4500000
    2 3/8"602
    3/8"-16
    61013064T4600000
    2 7/8"732 1/2
    1/2"-13
    97013064T4700000
    3 1/2"893
    1/2"-13
    97013064T4800000
    4"1023 1/2
    1/2"-13
    97013064T4900000
    4 1/2"1144
    5/8"-11
    1,25013064T5100000
     
    Pipe Cradles

    Drain, Waste, and Vent Iron and Steel Pipe Fittings

    Use these fittings in gravity-flow applications both above and below ground. They are also known as no-hub pipe fittings and soil pipe fittings. To connect, place the end of the fitting against your pipe or another fitting and connect with a low-pressure clamp-on connector (sold separately). The clamp-on connector is also known as a no-hub coupling. Fittings are for use in noncorrosive environments.
    Clamp Connectors
    Image of Product. Front orientation. Pipe and Fittings. Drain, Waste, and Vent Iron and Steel Pipe Fittings, Clamp Connectors, Clamp On.

    Clamp On

    304 Stainless Steel—Fittings hold up in humid, damp, and washdown environments but will corrode if exposed to salt water or chemicals.
    For Pipe
    Size
    Material
    Max. Pressure
    @ Temp.
    Sleeve
    Material
    Each
    Clamp On
    1 1/2
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K21000000
    2
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K2200000
    3
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K2300000
    4
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K2400000
    5
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K2500000
    6
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K2600000
    8
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K28000000
    10
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K29000000
    12
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K222000000
     
    Clamp Adapters
    Image of Product. Front orientation. Pipe and Fittings. Drain, Waste, and Vent Iron and Steel Pipe Fittings, Clamp Adapters, Clamp On × Clamp On.

    Clamp On ×

    Clamp On

    304 Stainless Steel—Fittings hold up in humid, damp, and washdown environments but will corrode if exposed to salt water or chemicals.
    For Pipe
    Size (A)
    Material
    Max. Pressure
    @ Temp.
    Sleeve
    Material
    Each
    Clamp On × Clamp On
    2
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K35000000
    3
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K3600000
    4
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K3700000
     
    Clamp Reducers
    Image of Product. Front orientation. Contains Annotated. Pipe and Fittings. Drain, Waste, and Vent Iron and Steel Pipe Fittings, Clamp Reducers, Clamp On × Clamp On.

    Clamp On × Clamp On

    304 Stainless Steel—Fittings hold up in humid, damp, and washdown environments but will corrode if exposed to salt water or chemicals.
    For
    Pipe Size
    (A)
    (B)
    Material
    Max. Pressure
    @ Temp.
    Sleeve
    Material
    Each
    Clamp On × Clamp On
    2
    1 1/2
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K41000000
    3
    2
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K4200000
    4
    3
    304 Stainless Steel15 psi @ 72° FNeoprene
    6820K4300000
     

    Routing S-Hooks

    Image of ProductInUse. Front orientation. Contains MultipleImages. S-Hooks. Routing S-Hooks.
    Hang these S-hooks from fencing and railing to route large bundles of material, such as cable, hose, and wire through your facility or worksite to avoid tripping hazards.
    Rounded Hook
    Image of Product. Front orientation. Contains Annotated. S-Hooks. Routing S-Hooks, Rounded Hook.
    PVC-Coated Steel—PVC-coated steel hooks won’t scratch the hanging surface or routed material.
    Each
    Total No. of
    Bottom Hooks
    For Max.
    Bundle Dia.
    Thk.
    Usable
    Lg.
    Top Hook Opening
    Wd. × Inside Wd.
    Bottom Hook Opening Wd.
    × Inside Wd. (No. of)
    Temp. Range,
    ° F
    Wt. Cap.,
    lb.
    1-19
    20-99
    100-Up
    PVC-Coated Steel—Orange
    13"9/16"7 15/16"2" × 2 1/4"2 1/2" × 3" (1)0 to 1251252645N1200000000000000000
    14"11/16"9 11/16"2 7/8" × 3"3" × 4" (1)0 to 1251502645N11000000000000000
    15"11/16"10 11/16"2 7/8" × 3"4" × 5" (1)0 to 1251602645N13000000000000000
     

    Wire-Mount Routing Rings

    Image of Product. Front orientation. Routing Rings. Wire-Mount Routing Rings.
    Hang cable and other flexible material beneath wire to prevent it from sagging and swaying. Rings are made of rigid, plastic-coated steel. The plastic coating prevents damage to wire and cable. To install, hook the two ends of the ring around the wire—no fasteners required.
    For
    Max.
    Coating
    Overall
    Bundle
    Dia.
    Wire
    Dia.
    Material
    Material
    Color
    Temp. Range,
    ° F
    Wt. Cap.,
    lb.
    Lg.
    Ht.
    Each
    2 1/4"3/8"Galvanized SteelPVC
    Black0 to 1252853 3/4"4 1/8"2647N11000000
    3"3/8"Galvanized SteelPVC
    Black0 to 1253004 3/4"5"2647N1200000
     

    Strut Channel Routing Clamps

    Image of ProductInUse. Clamp Shown Installed. Front orientation. Strut Channel Framing and Fittings. Strut Channel Routing Clamps.
    Image of Product. Front orientation. Contains Annotated. Strut Channel Framing and Fittings. Strut Channel Routing Clamps, Style 1.

    Clamp Shown Installed

    Style 1

    Run pipe, conduit, and tubing through your facility by attaching it to strut channel. Since you don’t have to drill into beams and walls, it's easy to reconfigure setups as needed. Just slide clamps into the end of channel and tighten the screw.
    PVC-Coated Steel—With a layer of PVC, these won't wear or cut into PVC-coated conduit and tubing. This keeps the coating intact to prevent rust and extend the life of conduit in high-vibration environments.
    ID
    Inch
    Metric,
    mm
    For Pipe
    Size
    For Channel
    Wd.
    Lg.
    Wd.
    Ht.
    Thk.
    Wt. Cap.,
    lb.
    Each
    Style 1
     
    PVC-Coated Steel
    5/8"161/2
    1 5/8"3/4"1 1/4"2 3/16"5/64"4003115T7100000
    15/16"243/4
    1 5/8"1 1/16"1 1/4"2 7/16"1/16"6003115T720000
    1 3/16"301
    1 5/8"1 5/16"1 1/4"2 11/16"5/64"6003115T730000
    1 7/16"371 1/4
    1 5/8"1 9/16"1 1/4"3 1/16"5/64"6003115T740000
    1 11/16"431 1/2
    1 5/8"1 7/8"1 1/4"3 5/16"7/64"8003115T750000
    2 3/16"562
    1 5/8"2 3/8"1 1/4"3 3/4"7/64"8003115T760000
    3 1/2"883
    1 5/8"3 11/16"1 1/4"5 1/4"7/64"8003115T55100000
    4 1/2"1144
    1 5/8"4 3/4"1 1/4"6 1/4"1/8"1,0003115T55200000
    6 5/8"1686
    1 5/8"6 7/8"1 1/4"8 7/8"9/64"1,0003115T55300000
     
    back to top