Connection Type Connection Type |
---|
![]() | ![]() |
Wire Leads | Flat Pin |
Probe Material Probe Material |
---|
|
Insulation Material Insulation Material |
---|
|
Jacket Material Jacket Material |
---|
|
Cable Material Cable Material |
---|
|
More
The probe tips come attached to mounting connections for fast installation.
Hose-clamp and hook-and-loop probes fit around pipes, tubes, and cylindrical containers.
Magnetic probes mount on any flat, ferrous surface.
Clip probes attach to vents, oven racks, circuit boards, and other irregular surfaces.
Bolt-on probes mount on motors, machines, and other equipment for temperature readings in high-vibration environments.
Adhesive-back probes stick to your surface and have a slim profile that fits in tight spots.
Thermocouple Type | Temperature Range, ° F | Opening Range | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Sensor Type | Cable Material | Max. Cable Temperature, ° F | Pin Lg. | Wd. | Fasteners Included | Each | |
Stainless Steel Probe | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
J | 32° to 250° | 11/16" - 1 1/4" | ±0.75% | 25 | 10 | Flat Pin | Grounded | Stainless Steel | 950° | 1/2" | 9/16" | Yes | 000000000 | 000000 |
J | 32° to 250° | 13/16" - 1 1/2" | ±0.75% | 25 | 10 | Flat Pin | Grounded | Stainless Steel | 950° | 1/2" | 9/16" | Yes | 000000000 | 00000 |
J | 32° to 250° | 1 5/16" - 2 1/4" | ±0.75% | 25 | 10 | Flat Pin | Grounded | Stainless Steel | 950° | 1/2" | 9/16" | Yes | 000000000 | 00000 |
K | 32° to 250° | 11/16" - 1 1/4" | ±0.75% | 25 | 10 | Flat Pin | Grounded | Stainless Steel | 950° | 1/2" | 9/16" | Yes | 000000000 | 00000 |
K | 32° to 250° | 13/16" - 1 1/2" | ±0.75% | 25 | 10 | Flat Pin | Grounded | Stainless Steel | 950° | 1/2" | 9/16" | Yes | 000000000 | 00000 |
K | 32° to 250° | 1 5/16" - 2 1/4" | ±0.75% | 25 | 10 | Flat Pin | Grounded | Stainless Steel | 950° | 1/2" | 9/16" | Yes | 000000000 | 00000 |
Material | Strap | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, ° F | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Sensor Type | Cable | Insulation | Jacket | Max. Cable Temperature, ° F | Pin Lg. | Wire Gauge | Wd. | Lg. | Each | |
Nylon Probe | ||||||||||||||||
J | -310° to 250° | ±3° F | 60 | 10 | Flat Pin | Exposed | PVC Plastic | PVC | PVC | 250° | 1/2" | 24 | 1" | 8" | 000000000 | 000000 |
K | -415° to 250° | ±3° F | 60 | 10 | Flat Pin | Exposed | PVC Plastic | PVC | PVC | 250° | 1/2" | 24 | 1" | 8" | 000000000 | 00000 |
Probe | Material | Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, ° F | Lg. | Dia. | Accuracy | Cable Lg., ft. | Connection Type | Sensor Type | Cable | Insulation | Jacket | Max. Cable Temperature, ° F | Lead Lg. | Gauge | Holding Force, lbs. | Each | |
Stainless Steel Probe | ||||||||||||||||
J | 32° to 1000° | 1/2" | 1" | ±0.75% | 6 | Wire Leads | Exposed | Fiberglass | Fiberglass | Fiberglass | 1000° | 1/4" | 24 | 16 | 0000000 | 0000000 |
K | 32° to 1000° | 1/2" | 1" | ±0.75% | 6 | Wire Leads | Exposed | Fiberglass | Fiberglass | Fiberglass | 1000° | 1/4" | 24 | 16 | 0000000 | 000000 |
Material | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, ° F | Probe Lg. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Sensor Type | Cable | Insulation | Jacket | Max. Cable Temperature, ° F | Pin Lg. | Wire Gauge | Opening Size | Each | |
Brass Probe | ||||||||||||||||
J | -310° to 250° | 2" | ±5° F | 5 | 5 | Flat Pin | Exposed | PVC Plastic | PVC | PVC | 250° | 1/2" | __ | 3/8" | 00000000 | 000000 |
J | -310° to 850° | 2" | ±5° F | 5 | 10 | Flat Pin | Exposed | Stainless Steel | Glass | Glass | 900° | 1/2" | 24 | 3/8" | 00000000 | 00000 |
K | -415° to 250° | 2" | ±5° F | 5 | 5 | Flat Pin | Exposed | PVC Plastic | PVC | PVC | 250° | 1/2" | __ | 3/8" | 00000000 | 00000 |
K | -415° to 850° | 2" | ±5° F | 5 | 10 | Flat Pin | Exposed | Stainless Steel | Glass | Glass | 900° | 1/2" | 24 | 3/8" | 00000000 | 00000 |
Material | Wire | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, ° F | Probe Lg. | Accuracy | Response Time, sec. | Connection Type | Sensor Type | Insulation | Jacket | Lead Lg. | Gauge | Wd. | Thick. | Bolt Hole Dia. | Fasteners Included | Each | |
Nickel Probe | ||||||||||||||||
J | 32° to 900° | 5/8" | ±0.75% | 2 | Wire Leads | Grounded | Fiberglass | 300 Series Stainless Steel | 48" | 24 | 5/16" | 1/16" | 3/16" | No | 0000000 | 000000 |
K | 32° to 900° | 5/8" | ±0.75% | 2 | Wire Leads | Grounded | Fiberglass | 300 Series Stainless Steel | 48" | 24 | 5/16" | 1/16" | 3/16" | No | 0000000 | 00000 |
T | 32° to 900° | 5/8" | ±0.75% | 2 | Wire Leads | Grounded | Fiberglass | 300 Series Stainless Steel | 48" | 24 | 5/16" | 1/16" | 3/16" | No | 0000000 | 00000 |
Material | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, ° F | Probe Lg. | Accuracy | Response Time, sec. | Connection Type | Sensor Type | Insulation | Jacket | Lead Lg. | Gauge | Wd. | Thick. | Each | |
Polyimide Probe | ||||||||||||||
J | 32° to 400° | 1 1/4" | ±0.75% | 2 | Wire Leads | Exposed | Fiberglass | Fiberglass | 48" | 30 | 1" | 1/16" | 0000000 | 000000 |
K | 32° to 400° | 1 1/4" | ±0.75% | 2 | Wire Leads | Exposed | Fiberglass | Fiberglass | 48" | 30 | 1" | 1/16" | 0000000 | 00000 |
T | 32° to 400° | 1 1/4" | ±0.75% | 2 | Wire Leads | Exposed | Fiberglass | Fiberglass | 48" | 30 | 1" | 1/16" | 0000000 | 00000 |