Industry Designation Industry Designation | Show |
|---|
Industry Designation Industry Designation | Hide |
|---|
System of Measurement System of Measurement |
|---|
|
Cable AWG Cable AWG |
|---|
Use For Use For |
|---|
|
Wire Type Wire Type |
|---|
Flexibility Flexibility |
|---|
![]() | Flexible |
Current Current |
|---|
|
|
Outer Insulation Material Outer Insulation Material |
|---|
|
Shielding Shielding |
|---|
| Unshielded | |
Wire Finish Wire Finish |
|---|
|
Maximum Temperature Maximum Temperature |
|---|
|
Inner Insulation Marking Inner Insulation Marking |
|---|
|
Specifications Met Specifications Met |
|---|
|
Inner Insulation Material Inner Insulation Material |
|---|
|
Wire Material Wire Material |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
About Industry Designation for Cable Insulation
More
About Extension Cords
More
About Wire and Cable
More
About Hazardous Location Environmental Ratings
More
Cable
Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -55° to 220° F
Yellow: -75° to 220° F - Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
| 18 | 2 | 18/2 | 10 A @ 86° F | 0.34" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
| 18 | 3 | 18/3 | 10 A @ 86° F | 0.36" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
| 18 | 4 | 18/4 | 7 A @ 86° F | 0.39" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
| 16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 00000000 | 000 | 000 | |
| 16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
| 16 | 4 | 16/4 | 10 A @ 86° F | 0.42" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 14 | 2 | 14/2 | 18 A @ 86° F | 0.5" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 14 | 3 | 14/3 | 18 A @ 86° F | 0.52" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 14 | 4 | 14/4 | 15 A @ 86° F | 0.56" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 12 | 2 | 12/2 | 25 A @ 86° F | 0.57" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 00000000 | 0000 | 0000 | |
| 12 | 3 | 12/3 | 25 A @ 86° F | 0.59" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 12 | 4 | 12/4 | 20 A @ 86° F | 0.64" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 10 | 3 | 10/3 | 30 A @ 86° F | 0.65" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 10 | 4 | 10/4 | 25 A @ 86° F | 0.7" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 8 | 3 | 8/3 | 40 A @ 86° F | 0.7" | Black, Green, White | __ | Bare Copper | 0000000 | 0000 | 0000 | |
| 8 | 4 | 8/4 | 35 A @ 86° F | 0.78" | Black, Green, Red, White | __ | Bare Copper | 0000000 | 0000 | 0000 | |
| 6 | 3 | 6/3 | 55 A @ 86° F | 0.81" | Black, Green, White | __ | Bare Copper | 00000000 | 0000 | 0000 | |
| 6 | 4 | 6/4 | 45 A @ 86° F | 0.89" | Black, Green, Red, White | __ | Bare Copper | 00000000 | 0000 | 0000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
| 16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 16 | 4 | 16/4 | 10 A @ 86° F | 0.41" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 14 | 3 | 14/3 | 18 A @ 86° F | 0.52" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 14 | 4 | 14/4 | 15 A @ 86° F | 0.56" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 12 | 3 | 12/3 | 25 A @ 86° F | 0.6" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 12 | 4 | 12/4 | 20 A @ 86° F | 0.64" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
| 10 | 4 | 10/4 | 25 A @ 86° F | 0.7" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
Extension Cords for Hazardous Locations

Use these cords where ignitable gas and dust may be present. The industry designation is SEOOW, so the inner and outer insulation resists oil.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Cord | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Lg., ft. | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Environmental Rating | Specifications Met | Color | Each | |
NEMA 5-20 Plug × NEMA 5-20 Socket | ||||||||||||
| 50 | 10 | 20 | 125V AC | Without Power-Indicating Light | 0.66" | TPE Rubber | SEOOW | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups F, G | CSA Certified | Black | 0000000 | 000000000 |
NEMA 6-20 Plug × NEMA 6-20 Socket | ||||||||||||
| 50 | 10 | 20 | 250V AC | Without Power-Indicating Light | 0.66" | TPE Rubber | SEOOW | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups F, G | CSA Certified | Black | 0000000 | 00000000 |