Shielding Shielding |
---|
![]() | Double Shielded |
![]() | Shielded |
Use For Use For |
---|
|
Inner Insulation Color Inner Insulation Color |
---|
![]() | Black |
![]() | Green/Yellow |
![]() | Blue |
![]() | Brown |
![]() | Green |
![]() | Red |
![]() | Yellow |
![]() | Orange |
![]() | Purple |
![]() | Gray |
![]() | Pink |
![]() | White |
Wire Finish Wire Finish |
---|
|
Specifications Met Specifications Met |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
Servomotor Continuous-Flex Cable


- Use For: Automation, Continuous Motion, Interference Shielding, Motors
- Continuous Flex
- Temperature Range: -40° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: Polypropylene Plastic
Connect servocontrollers and servomotors in automated equipment and on assembly lines. This cable withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion and oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Cable with power wires sends electricity to run a servomotor.
Cable with signal wires is also known as feedback cable. It sends and receives signals between a servomotor and a PLC.
Cable with power and signal wires sends data such as positioning information from a servomotor to a controller. It has four power wires and two pairs of signal wires.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.

Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Wires | Wire Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-49 | 50-Up | |
Double Shielded—1,000V AC | ||||||||||||
4 | 14 | 14/4 | 15 A @ 86° F | 0.42" | 3.15" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 00000 | 00000 | |
4 | 12 | 12/4 | 20 A @ 86° F | 0.47" | 3.53" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 0000 | 0000 | |
4 | 10 | 10/4 | 30 A @ 86° F | 0.57" | 4.28" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 00000 | 00000 |

No. of Wires | Wire Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Shielded—30V AC/45V DC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8 | 26 | 26/8 | 0.7 A @ 86° F | 0.25" | 2.17" | Green | Black, Blue, Brown, Green, Orange, Purple, Red, Yellow | UL Recognized Component, Flame Rated VW-1 | 0000000 | |||||
8 | 24 | 24/8 | 1.4 A @ 86° F | 0.29" | 1.87" | Green | Blue, Brown, Gray, Green, Pink, Red, White, Yellow | UL Recognized Component, Flame Rated VW-1 | 0000000 |

Power Wire | Signal Wire | Per Ft. | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-49 | 50-Up | |
Double Shielded—1,000V AC | ||||||||||||||||||
4 | 14 | 14/4 | 4 | 18 | 18/4 | __ | __ | __ | 15 A @ 86° F | 0.57" | 4.28" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 000000 | 00000 | |
4 | 12 | 12/4 | 2 | 18 | 18/2 | 2 | 16 | 16/2 | 20 A @ 86° F | 0.64" | 4.8" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 00000 | 00000 | |
4 | 10 | 10/4 | 2 | 18 | 18/2 | 2 | 16 | 16/2 | 30 A @ 86° F | 0.71" | 5.33" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 00000 | 00000 |