Space-Saver Stairs

Also known as ship's ladders, these stairs have a 75° climbing angle to fit in pits, trenches, wells, and other tight spaces. Handrails extend 42" beyond the top landing for a walk-through exit. Steps are perforated for good slip resistance.
Note: Stairs meet OSHA dimensional standards. Users are responsible for checking local, state, and federal codes, including OSHA, for safe installation and operating practices.
Stairs | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Step | Handrail | Replacement Handrails | ||||||||||||||
Landing Ht. (A) | Wd. | Dp. (B) | Climbing Angle | No. of Steps | Dp. | Tread | Top Step Dp. | Cap., lbs. | Ht. | Color | Mounting Hardware Included | Assembled or Unassembled | Specifications Met | Each | Each | ||
Galvanized Steel | |||||||||||||||||
24" Wide Steps | |||||||||||||||||
3'8" to 4'7 1/2" | 29" | 23" | 75° | 4 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 0000000 | 000000 | 000000 |
4'7 1/2" to 5'7" | 29" | 26" | 75° | 5 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
5'7" to 6'6" | 29" | 29" | 75° | 6 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
6'6" to 7'6" | 29" | 32" | 75° | 7 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
7'6" to 8'6" | 29" | 35" | 75° | 8 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 000000 | 000000 | 0000000 | 000000 |
8'6" to 9'5" | 29" | 38" | 75° | 9 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
9'5" to 10'5" | 29" | 41" | 75° | 10 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
10'5" to 11'5" | 29" | 44" | 75° | 11 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
30" Wide Steps | |||||||||||||||||
3'8" to 4'7 1/2" | 35" | 23" | 75° | 4 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
4'7 1/2" to 5'7" | 35" | 26" | 75° | 5 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
5'7" to 6'6" | 35" | 29" | 75° | 6 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
6'6" to 7'6" | 35" | 32" | 75° | 7 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
7'6" to 8'6" | 35" | 35" | 75° | 8 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
8'6" to 9'5" | 35" | 38" | 75° | 9 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
9'5" to 10'5" | 35" | 41" | 75° | 10 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
10'5" to 11'5" | 35" | 44" | 75° | 11 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
Forward Descent Space-Saver Stairs


These stairs have offset steps that allow for a comfortable and safe forward descent. Set at a steeper angle than our standard stairs, they require less floor space. Steps are perforated for good slip resistance.
Note: Stairs meet OSHA or Cal/OSHA dimensional and construction standards. Check local, state, and federal codes, including OSHA, for safe set up and operating practices.
Also Available: Other landing heights (dimension A) from 3 1/2 feet up to 20 feet. Please select 7946T9 and specify height in inches. To determine the price, multiply your landing height in inches by $20.20 and add $362.28.
Overall | Step | Handrail | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Landing Ht. (A), ft. | Wd. | Dp. (B) | Climbing Angle | No. of Steps | Wd. | Dp. | Tread | Material | Color | Ht. | Color | Mounting Hardware Included | Assembled or Unassembled | Specifications Met | Each | |
OSHA Compliant | ||||||||||||||||
350-lb. Capacity | ||||||||||||||||
4 | 23 5/8" | 30" | 68° | 7 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 000000000 |
5 | 23 5/8" | 35" | 68° | 8 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
6 | 23 5/8" | 40" | 68° | 10 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
7 | 23 5/8" | 45" | 68° | 12 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
8 | 23 5/8" | 50" | 68° | 13 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
9 | 23 5/8" | 55" | 68° | 15 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
10 | 23 5/8" | 59" | 68° | 16 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
11 | 23 5/8" | 64" | 68° | 17 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
12 | 23 5/8" | 69" | 68° | 20 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
13 | 23 5/8" | 74" | 68° | 21 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
14 | 23 5/8" | 79" | 68° | 24 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 00000000 | 00000000 |
Cal/OSHA Compliant | ||||||||||||||||
600-lb. Capacity | ||||||||||||||||
4 | 23" | 26" | 68° | 6 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
5 | 23" | 31" | 68° | 7 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
6 | 23" | 36" | 68° | 8 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
7 | 23" | 40" | 68° | 10 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
8 | 23" | 45" | 68° | 11 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
9 | 23" | 50" | 68° | 12 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
10 | 23" | 55" | 68° | 14 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
11 | 23" | 60" | 68° | 15 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
12 | 23" | 65" | 68° | 16 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
13 | 23" | 70" | 68° | 18 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
14 | 23" | 74" | 68° | 19 | 9" | 10 1/2" | Perforated | Powder-Coated Steel | Yellow | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, ANSI/ASSE A1264.1, NFPA 101 7.2.11 | 0000000 | 00000000 |
Top-Mount Stairs

Mount these stairs to an elevated landing for easy access. They have adjustable mounting brackets to accommodate slight differences in landing heights. Steps are perforated to provide slip resistance that’s easy on your shoes.
Stairs that meet OSHA standards are intended for use in private facilities, such as factories and other industrial settings. Set at a steeper angle than IBC (International Building Code) stairs, they require less floor space.
Stairs that meet IBC standards are used in commercial buildings that may be accessed by the general public. With larger step dimensions and a shallower angle than OSHA stairs, they are easier to climb. In addition, the vertical space between steps is covered to prevent debris from falling through.
Note: Stairs meet OSHA or IBC dimensional standards. Users are responsible for checking local, state, and federal codes, including OSHA or IBC, for safe installation and operating practices.
Overall | Step | Handrail | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Landing Ht. (A) | Wd. | Dp. (B) | Climbing Angle | No. of Steps | Dp. | Tread | Cap., lbs. | Ht. | Color | Mounting Hardware Included | Assembled or Unassembled | Specifications Met | Each | |
Galvanized Steel | ||||||||||||||
30" Wide Steps | ||||||||||||||
3'2" to 3'8" | 43" | 3'3" to 3'7" | 35°-42° | 4 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 000000000 |
3'11" to 4'5" | 43" | 4'0" to 4'5" | 35°-42° | 5 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
4'6" to 5'1" | 43" | 5'0" to 5'4" | 35°-42° | 6 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
5'2" to 5'9" | 43" | 5'9" to 6'3" | 35°-42° | 7 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
5'10" to 6'6" | 43" | 6'7" to 7'1" | 35°-42° | 8 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
6'7" to 7'2" | 43" | 7'6" to 7'11" | 35°-42° | 9 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
7'3" to 7'11" | 43" | 8'3" to 8'9" | 35°-42° | 10 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
8'0" to 8'8" | 43" | 9'1" to 9'7" | 35°-42° | 11 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
8'9" to 9'5" | 43" | 9'11" to 10'5" | 35°-42° | 12 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
9'6" to 10'10" | 43" | 11'7" to 12'6" | 35°-42° | 14 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
36" Wide Steps | ||||||||||||||
3'0" to 3'6" | 47" | 4'8" to 4'11" | 28°-33° | 5 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
3'2" to 3'8" | 49" | 3'3" to 3'7" | 35°-42° | 4 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
3'7" to 4'0" | 47" | 5'7" to 5'11" | 28°-33° | 6 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
3'11" to 4'5" | 49" | 4'0" to 4'5" | 35°-42° | 5 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
4'1" to 4'7" | 47" | 6'6" to 6'10" | 28°-33° | 7 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
4'8" to 5'1" | 47" | 7'5" to 7'10" | 28°-33° | 8 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
5'2" to 5'9" | 49" | 5'9" to 6'3" | 35°-42° | 7 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
5'2" to 5'10" | 47" | 8'4" to 8'10" | 28°-33° | 9 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
6'0" to 7'0" | 47" | 10'1" to 10'9" | 28°-33° | 11 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
7'1" to 8'2" | 47" | 12'0" to 12'9" | 28°-33° | 13 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
8'0" to 8'8" | 49" | 9'1" to 9'7" | 35°-42° | 11 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
9'6" to 10'10" | 49" | 11'7" to 12'6" | 35°-42° | 14 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
Foldaway Stairs




Extend these stairs out to reach a storage or work area, then fold them flat against the wall when you’re done. The handrail locks onto the stairs to keep them from folding while you climb. Made of steel, they’re durable enough to withstand heavy use. Their powder coating helps prevent rust. Serrated steps prevent slipping and allow liquids and dirt to pass through. All include a mounting bracket that you can weld or bolt to your surface.
Extend manual stairs by pumping a lever. Push them flat to store.
Electric stairs extend or retract with the push of a button. To power, plug them into a standard 120V AC outlet.
Note: Stairs meet OSHA dimensional and construction standards. Check local, state, and federal codes, including OSHA, for safe set up and operating practices.
Overall | Step | Handrail | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Landing Ht. (A), ft. | Wd. | Dp. (B) | Climbing Angle | No. of Steps | Wd. | Dp. | Tread | Cap., lbs. | Ht. | Color | Motor Input Voltage | Plug Type | Mounting Hardware Included | Assembled or Unassembled | Specifications Met | Each | |
Blue Powder-Coated Steel | |||||||||||||||||
Manual | |||||||||||||||||
5 | 33" | 43" | 58° | 7 | 24 1/4" | 7" | Serrated | 350 | 31 1/2" | Yellow | __ | __ | No | Unassembled | OSHA Compliant 29 CFR 1910.25 | 0000000 | 000000000 |
6 | 33" | 50" | 58° | 8 | 24 1/4" | 7" | Serrated | 350 | 31 1/2" | Yellow | __ | __ | No | Unassembled | OSHA Compliant 29 CFR 1910.25 | 0000000 | 00000000 |
7 | 33" | 58" | 58° | 9 | 24 1/4" | 7" | Serrated | 350 | 31 1/2" | Yellow | __ | __ | No | Unassembled | OSHA Compliant 29 CFR 1910.25 | 0000000 | 00000000 |
8 | 33" | 65" | 58° | 10 | 24 1/4" | 7" | Serrated | 350 | 31 1/2" | Yellow | __ | __ | No | Unassembled | OSHA Compliant 29 CFR 1910.25 | 0000000 | 00000000 |
9 | 33" | 73" | 58° | 11 | 24 1/4" | 7" | Serrated | 350 | 31 1/2" | Yellow | __ | __ | No | Unassembled | OSHA Compliant 29 CFR 1910.25 | 0000000 | 00000000 |
10 | 33" | 80" | 58° | 13 | 24 1/4" | 7" | Serrated | 350 | 31 1/2" | Yellow | __ | __ | No | Unassembled | OSHA Compliant 29 CFR 1910.25 | 0000000 | 00000000 |
Electric | |||||||||||||||||
9 | 32" | 73" | 58° | 11 | 23 5/8" | 7" | Serrated | 350 | 32" | Yellow | 120V AC | Three Prong | No | Unassembled | OSHA Compliant 29 CFR 1910.25 | 0000000 | 00000000 |