McMaster-Carr logo
    Filter by
    For Use With
    Calibrated With
    Switch Designation
    Industrial Info Compare
    Set Point Configuration
    Mounting Position
    Electrical Connection
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Flow Measurement Type
    Switch Starting Position
    Industrial Info Compare
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    56 Products

    Fixed-Set-Point Flow Switches

    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.
    Image of Product. Style D. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style D.
    Image of Product. Style E. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style E.

    Style C

    Style D

    Style E

    Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Straight
    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.

    Style C

    316 Stainless Steel Fitting and Bronze Fitting—Bronze and 316 stainless steel fittings resist impact better than plastic fittings.
    SPDT—SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
    Conduit
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Mounting
    Position
    Each
    Bronze Body with Bronze Fittings
     
    SPDT
    C1
    NPT
    Female0.50.075400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle000000000000000
    C1
    NPT
    Female10.15300 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 3/8"Any Angle0000000000000
    C1
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female30.45400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 3/8"Any Angle0000000000000
    C1
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female60.9400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female81.2400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1 1/4
    NPT
    Female10.15400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle00000000000000
    C1 1/4
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle00000000000000
    C1 1/4
    NPT
    Female203400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle00000000000000
    C1 1/2
    NPT
    Female1.50.225400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle00000000000000
    C1 1/2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle00000000000000
    C1 1/2
    NPT
    Female304.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle00000000000000
    C2
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle00000000000000
    C2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle00000000000000
    C2
    NPT
    Female507.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle00000000000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    SPDT
    C1
    NPT
    Female0.50.075400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female60.9400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female81.2400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C2
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle0000000000000000
    C2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle0000000000000000
    C2
    NPT
    Female507.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle0000000000000000
     
    90° Elbow
    Image of Product. Style D. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style D.
    Image of Product. Style E. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style E.

    Style D

    Style E

    Polypropylene Fitting—Polypropylene and PPS fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    SPST—SPST (single pole, single throw) switches turn one device from off to on (normally open).
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Mounting
    Position
    Each
    Polypropylene Body with Polypropylene Fittings
     
    SPST
    D1/4
    NPT
    Female0.0420.006200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    Any Angle0000000000000
    E3/4
    NPT
    Female0.250.05100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle0000000000000
    E3/4
    NPT
    Female10.2100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle0000000000000
     

    Fixed-Set-Point Flow Switches for Drinking Water

    Image of Product. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches for Drinking Water.
    Factory set to activate equipment when your drinking water system reaches a fixed level, these flow switches are easier to install than adjustable flow switches. They meet NSF/ANSI 61, so they're safe to use with drinking water. They actuate when your system’s flowing water pushes their paddle into a set position. These switches are single pole, single throw (SPST) and turn one device from off to on. IP rated, they seal out dust and can be lightly rinsed. They're accurate in any mounting position.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Pipe
    Connections
    Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage
    Max. Switching Current
    @ Voltage
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Food Industry
    Std.
    Each
    Noryl Body with Threaded Brass Fittings
    1/2 NPT Female0.6145 psi @ 70° F-4 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2"IP65
    CE Marked
    NSF/ANSI 61
    00000000000000
     

    Flow Switches

    Activate or deactivate equipment when your flow rate reaches a set point. These switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Straight
    Image of Product. Front orientation. Flow Switches. Flow Switches, Straight.
    Conduit
    Pipe
    Connections
    Flow Set
    Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Each
    Bronze Body
    1 NPT Female1 to 6400 psi @ 70° F-20 to 200120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male3 1/4"00000000000000
    1 NPT Female2 to 8400 psi @ 70° F-20 to 200120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male3 1/4"0000000000000
    1 NPT Female5 to 15400 psi @ 70° F-20 to 200120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male3 1/4"0000000000000
     
    90° Elbow
    Image of Product. Front orientation. Contains Annotated. Flow Switches. Flow Switches, 90° Elbow.
    Conduit
    Pipe
    Connections
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Port-to-Port
    Lg.
    Each
    Bronze Body
    3/4 NPT Female0.75 to 4400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"00000000000000
    3/4 NPT Female2 to 8400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"0000000000000
    3/4 NPT Female7 to 14400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"0000000000000
     

    Electronic Flow Switches

    Image of Product. Front orientation. Flow Switches. Electronic Flow Switches.
    When these switches reach a set flow rate, they send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms. Use the adjustment screw to select their set point. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They must be mounted horizontally to function correctly. IP rated, they withstand dust, washdowns, and temporary submersion.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    Aluminum/Brass/Plastic Body with Threaded Nickel-Plated Brass Fittings
     
    1 PNP Signal Output
    3/4 NPT Female0.26 to 6.6360 psi @ 70° F32 to 18530100 mA @ 30V DC3"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    00000000000000
    1 NPT Female1.32 to 26.4360 psi @ 70° F32 to 18530100 mA @ 30V DC3 5/8"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    0000000000000
     

    High-Pressure Flow Switches for Oil

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches for Oil.
    Measure the flow rate of oil at pressures up to 3,600 psi to activate or deactivate equipment. Designed to compensate for viscosity and density changes, these switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). Their IP65 rating protects them from dust and low-pressure washdowns, such as from a garden hose. All are accurate in any mounting position.
    These switches are calibrated with and measure oil accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Brass Body with Brass Fittings
    1/4 NPT Female0.03 to 0.12Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    00000000000000
    1/4 NPT Female0.05 to 0.3Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1/4 NPT Female0.2 to 0.9Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1/4 NPT Female0.5 to 2.5Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1/2 NPT Female1.5 to 5Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    3/4 NPT Female1 to 11Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    3/4 NPT Female2 to 18Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1 NPT Female2 to 20Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    7 5/16"IP65
    0000000000000
     

    High-Pressure Flow Switches for Gas

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches for Gas.
    Good for compressed-air systems and other compressed gases that reach up to 3,600 psi, these switches measure the flow rate to activate or deactivate equipment when they reach a set point. Tighten or loosen the adjustment screw to choose your flow rate anywhere within the set point range. As flowing gas pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
    These switches are calibrated with and measure air accurately. They can also be used with other gases by applying your gases’ specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    scfm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current
    @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Nickel-Plated Brass Body with 304 Stainless Steel Fittings
    1/4 NPT Female0.4 to 4Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    00000000000000
    1/4 NPT Female2 to 10Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/4 NPT Female3 to 24Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/2 NPT Female4 to 30Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    0000000000000
    3/4 NPT Female10 to 90Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 7/8"IP65
    0000000000000
    3/4 NPT Female30 to 130Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 7/8"IP65
    0000000000000
     

    High-Pressure Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches.
    Rated for pressures up to 3,600 psi, these switches measure the flow rate of liquids to activate or deactivate equipment when your flow rate reaches a set point. Tighten or loosen the adjustment screw on these switches to choose your flow rate anywhere within set point the range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current
    @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Nickel-Plated Brass Body with 304 Stainless Steel Fittings
    1/4 NPT Female0.06 to 0.8Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    00000000000000
    1/4 NPT Female0.25 to 2.6Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/4 NPT Female0.3 to 6Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/2 NPT Female1 to 8Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/2 NPT Female2 to 10Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 7/8"IP65
    0000000000000
    3/4 NPT Female8 to 34Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 7/8"IP65
    0000000000000
     
    back to top