About Flow Control Valves
Also known as cylinder speed controls, flow control valves let you control the extension or retraction speed of your air cylinder. They regulate airflow as it passes from the valve's inlet to its outlet. Air flows freely in the opposite direction.
More
About Air Preparation
More
Slow-Start Air-Exhaust Valves for Wilkerson Modular
Compressed Air Filter/Regulator/Lubricators (FRLs)

Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your Wilkerson components.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Valve | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Series | Inlet | Outlet | Exhaust | Type | Starting Position | Max. Flow Rate | Max. Pressure, psi | Temperature Range, °F | Ht. | Wd. | Dp. | Each | |
120V AC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 18 | |||||||||||||
E18 | 1/4 | 1/4 | 3/8 | Poppet | Normally Closed | 80 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 0000000 |
E18 | 3/8 | 3/8 | 3/8 | Poppet | Normally Closed | 90 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
E18 | 1/2 | 1/2 | 3/8 | Poppet | Normally Closed | 95 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
Series No. 28 | |||||||||||||
E28 | 3/4 | 3/4 | 3/8 | Spool | Normally Closed | 230 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
24V DC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 18 | |||||||||||||
E18 | 1/4 | 1/4 | 3/8 | Poppet | Normally Closed | 80 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
E18 | 3/8 | 3/8 | 3/8 | Poppet | Normally Closed | 90 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
E18 | 1/2 | 1/2 | 3/8 | Poppet | Normally Closed | 95 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
Series No. 28 | |||||||||||||
E28 | 3/8 | 3/8 | 3/8 | Spool | Normally Closed | 196 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
E28 | 1/2 | 1/2 | 3/8 | Spool | Normally Closed | 210 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
E28 | 3/4 | 3/4 | 3/8 | Spool | Normally Closed | 230 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
Slow-Start Air-Exhaust Valves for SMC Modular
Compressed Air Filter/Regulator/Lubricators (FRLs)

Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your SMC components.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Valve | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Series | Inlet | Outlet | Exhaust | Type | Starting Position | Max. Flow Rate | Max. Pressure, psi | Temperature Range, °F | Ht. | Wd. | Dp. | Each | |
120V AC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 50 | |||||||||||||
AVL5000 | 3/4 | 3/4 | 3/4 | Spool | Normally Closed | 250 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 0000000 |
AVL5000 | 1 | 1 | 1 | Spool | Normally Closed | 270 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 000000 |
24V DC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 50 | |||||||||||||
AVL5000 | 3/4 | 3/4 | 3/4 | Spool | Normally Closed | 250 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 000000 |
AVL5000 | 1 | 1 | 1 | Spool | Normally Closed | 270 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 000000 |
Slow-Start Air-Exhaust Valves for Festo Modular
Compressed Air Filter/Regulator/Lubricators (FRLs)

Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your Festo components.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Valve | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Series | Inlet | Outlet | Exhaust | Type | Starting Position | Max. Flow Rate | Max. Pressure, psi | Temperature Range, °F | Voltage | Ht. | Wd. | Dp. | Each | |
NPT Female Inlet, Outlet, and Exhaust | ||||||||||||||
Series No. 6 | ||||||||||||||
MS6 | 1/2 | 1/2 | 3/4 | Spool | Normally Closed | 201 scfm @ 88 psi | 145 | 35° to 140° | 24V DC | 7 5/16" | 2 7/16" | 3" | 0000000 | 0000000 |
MS6 | 3/4 | 3/4 | 3/4 | Spool | Normally Closed | 201 scfm @ 88 psi | 145 | 35° to 140° | 24V DC | 7 5/16" | 4 1/2" | 3" | 0000000 | 000000 |
Series No. 9 | ||||||||||||||
MS9 | 1 | 1 | 1 | Spool | Normally Closed | 581 scfm @ 88 psi | 235 | 35° to 140° | 24V DC | 10 11/16" | 4 1/8" | 4 5/16" | 0000000 | 000000 |
Slow-Start Air Flow Control Valves


Prevent damage to your equipment by limiting startup airflow and then gradually raising the airflow rate to operating levels. These valves adjust the volume of air exiting an air cylinder (meter out) to control the speed of air-powered equipment. They control flow in one direction; air flows freely in the opposite direction. For the best control, mount them as close to the cylinder as possible to minimize the length of tubing between the cylinder and the valve.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Maximum Flow Rate @ 73 psi | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type | ISO Designation | Each | |
NPT Female Inlet × NPT Female Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Zinc Body | ||||||||||
1/8 | 1/8 | 0.54 | 6 scfm | 101 | 32° to 140° | Dial | Exiting Cylinder | Meter Out | 00000000 | 000000 |
1/4 | 1/4 | 1.22 | 36 scfm | 101 | 32° to 140° | Dial | Exiting Cylinder | Meter Out | 00000000 | 00000 |
3/8 | 3/8 | 1.22 | 36 scfm | 101 | 32° to 140° | Dial | Exiting Cylinder | Meter Out | 00000000 | 00000 |
1/2 | 1/2 | 3.06 | 140 scfm | 101 | 32° to 140° | Dial | Exiting Cylinder | Meter Out | 00000000 | 000000 |
Timer-Operated Air On/Off Valves

Install these valves on your air storage tank outlet—at the end of the day, they automatically close to save energy. While in the off position, the tank stays pressurized so the compressor doesn't run when you don't need it to, even if there are small leaks from pipe fittings, drip legs, and other downstream connections. Also known as solenoid valves, these valves actuate when voltage is applied to the electrical connection. They operate on a timer that can be programmed to work with a regular schedule, but they also have a manual override if your schedule changes. They gradually open to prevent system damage from suddenly starting flow.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Cycles | No. of Ports | Pipe Size | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. On/Off, per Week | Timing | Flow | Inlet | Outlet | Inlet | Outlet | Flow Coefficient (Cv) | Max. Pressure, psi | Temp. Range, °F | Voltage | Electrical Connection Type | Cord Lg. | Lg. | Wd. | Ht. | Each | |
NPT Female Inlet × NPT Female Outlet | |||||||||||||||||
Brass Body with LCD Display | |||||||||||||||||
50 | 7 Day | 2 | 1 | 1 | 1 | 1 | 78.8 | 230 | 35° to 140° | 120V AC | Three-Prong Plug | 6 ft. | 2 15/16" | 6 3/16" | 7 5/32" | 0000000 | 0000000 |