Connection Style Connection Style | Show |
---|
![]() | Solder Connect |
Connection Style Connection Style | Hide |
---|
![]() |
Threaded |
![]() |
Socket Connect |
![]() |
Flanged |
![]() |
Threaded Union |
![]() |
Socket-Connect Union |
![]() |
Solder Connect |
![]() |
Barbed |
![]() |
Quick Clamp |
![]() |
Yor-Lok |
![]() |
Push to Connect |
![]() |
Butt Weld |
![]() |
Press Connect |
![]() |
Compression |
![]() |
Flared |
![]() |
Cam-and-Groove |
![]() |
Socket Weld |
System of Measurement System of Measurement |
---|
|
Handle Type Handle Type |
---|
|
Connection Type Connection Type |
---|
![]() | Tube |
Shape Shape |
---|
![]() | Straight |
Ball Material Ball Material |
---|
|
Valve Type Valve Type |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Fitting Type Fitting Type |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Ball Finish Ball Finish |
---|
|
Overall Length Overall Length |
---|
Overall Height Overall Height |
---|
Valve Operation Valve Operation |
---|
|
Packing Material Packing Material |
---|
|
Vacuum Rating Vacuum Rating |
---|
|
More
More
Solder these valves to metal tubing for a permanent, leak-tight connection.
Lockable lever handles can be fixed in place using a padlock (not included) with a shackle diameter up to 9/32”.
T-handles resist accidental movement when snagged or bumped.
Full-port valves do not restrict flow.
Standard-port valves slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Valves | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Repair Kits | ||||||||||||
ID | OD | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | Specifications Met | Each | Each | ||
Brass Body | |||||||||||||
Solder Connect × Solder Connect | |||||||||||||
1/2" | 5/8" | 46 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 2 1/4" | ANSI B16.22, C-UL Listed, UL Listed | 00000000 | 00000 | 000000 | 00 |
3/4" | 7/8" | 66 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 2 7/8" | ANSI B16.22, C-UL Listed, UL Listed | 00000000 | 00000 | 000000 | 00 |
1" | 1 1/8" | 93 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 3 3/8" | ANSI B16.22, C-UL Listed, UL Listed | 00000000 | 00000 | 000000 | 00 |
1 1/4" | 1 3/8" | 130 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 3 13/16" | ANSI B16.22, C-UL Listed, UL Listed | 00000000 | 00000 | 000000 | 00 |
1 1/2" | 1 5/8" | 290 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 4 1/2" | ANSI B16.22, C-UL Listed, UL Listed | 00000000 | 00000 | 000000 | 00 |
2" | 2 1/8" | 420 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 5 7/16" | ANSI B16.22, C-UL Listed, UL Listed | 00000000 | 00000 | 000000 | 00 |
2 1/2" | 2 5/8" | 590 | 300 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 6 5/8" | ANSI B16.22 | 00000000 | 000000 | 000000 | 00 |
3" | 3 1/8" | 740 | 300 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 7 5/8" | ANSI B16.22 | 00000000 | 000000 | 000000 | 00 |
Bronze Body | |||||||||||||
Solder Connect × Solder Connect | |||||||||||||
3/8" | 1/2" | 7 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Full | 2 1/4" | __ | 0000000 | 00000 | 000000 | 00 |
1/2" | 5/8" | 15 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Standard | 2 7/8" | __ | 0000000 | 00000 | 0000000 | 00000 |
1/2" | 5/8" | 16 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Full | 2 1/2" | __ | 0000000 | 00000 | 000000 | 00 |
3/4" | 7/8" | 30 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Standard | 3 7/8" | __ | 0000000 | 00000 | 0000000 | 00000 |
3/4" | 7/8" | 36 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Full | 3 3/16" | __ | 0000000 | 00000 | 000000 | 00 |
1" | 1 1/8" | 43 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Standard | 4 1/2" | __ | 0000000 | 00000 | 000000 | 00 |
1" | 1 1/8" | 68 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Full | 3 13/16" | __ | 0000000 | 00000 | 000000 | 00 |
1 1/4" | 1 3/8" | 48 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Standard | 4 5/8" | __ | 0000000 | 00000 | 000000 | 00 |
1 1/4" | 1 3/8" | 125 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Full | 4 3/16" | __ | 0000000 | 00000 | 000000 | 00 |
1 1/2" | 1 5/8" | 84 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Standard | 5 1/4" | __ | 0000000 | 00000 | 0000000 | 00000 |
1 1/2" | 1 5/8" | 177 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Full | 4 15/16" | __ | 0000000 | 000000 | 000000 | 00 |
2" | 2 1/8" | 108 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Standard | 6 3/8" | __ | 0000000 | 00000 | 0000000 | 00000 |
2" | 2 1/8" | 389 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29 | Full | 6 1/16" | __ | 0000000 | 000000 | 000000 | 00 |
For Tube | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
ID | OD | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | For Max. Shackle Dia. | Specifications Met | Each | |
Brass Body | ||||||||||||
Solder Connect × Solder Connect | ||||||||||||
1/2" | 5/8" | 46 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 2 1/4" | 9/32" | ANSI B16.22, C-UL Listed, UL Listed | 0000000 | 000000 |
3/4" | 7/8" | 66 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 2 7/8" | 9/32" | ANSI B16.22, C-UL Listed, UL Listed | 0000000 | 00000 |
1" | 1 1/8" | 93 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 3 3/8" | 9/32" | ANSI B16.22, C-UL Listed, UL Listed | 0000000 | 00000 |
1 1/4" | 1 3/8" | 130 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 3 13/16" | 9/32" | ANSI B16.22, C-UL Listed, UL Listed | 0000000 | 00000 |
1 1/2" | 1 5/8" | 290 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 4 1/2" | 9/32" | ANSI B16.22, C-UL Listed, UL Listed | 0000000 | 00000 |
2" | 2 1/8" | 420 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 5 7/16" | 9/32" | ANSI B16.22, C-UL Listed, UL Listed | 0000000 | 00000 |
2 1/2" | 2 5/8" | 590 | 300 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 6 5/8" | 9/32" | ANSI B16.22 | 0000000 | 000000 |
3" | 3 1/8" | 740 | 300 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 7 5/8" | 9/32" | ANSI B16.22 | 0000000 | 000000 |
For Tube | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
ID | OD | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | Each | |
Brass Body | ||||||||||
Solder Connect × Solder Connect | ||||||||||
1/2" | 5/8" | 46 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 2 1/4" | 0000000 | 000000 |
3/4" | 7/8" | 66 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 2 7/8" | 0000000 | 00000 |
1" | 1 1/8" | 93 | 500 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 3 3/8" | 0000000 | 00000 |
1 1/4" | 1 3/8" | 130 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 3 13/16" | 0000000 | 00000 |
1 1/2" | 1 5/8" | 290 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 4 1/2" | 0000000 | 00000 |
2" | 2 1/8" | 420 | 400 psi @ 100° F | 15 psi @ 250° F | 0° to 250° | 29.9 | Full | 5 7/16" | 0000000 | 00000 |
Service these valves without cutting soldered connections. Solder to metal tubing for a permanent, leak-tight connection. The three-piece bolted body can be disassembled inline for easy access to internal components. Valves are full port, so they do not restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Tube | |||||||||
---|---|---|---|---|---|---|---|---|---|
ID | OD | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | End-to-End Lg. | Each | |
Bronze Body | |||||||||
Solder Connect × Solder Connect | |||||||||
1/2" | 5/8" | 26 | 600 psi @ 100° F | 150 psi @ 365° F | -20° to 450° | 29 | 2 13/16" | 0000000 | 000000 |
3/4" | 7/8" | 51 | 600 psi @ 100° F | 150 psi @ 365° F | -20° to 450° | 29 | 3 7/16" | 0000000 | 00000 |
1" | 1 1/8" | 68 | 600 psi @ 100° F | 150 psi @ 365° F | -20° to 450° | 29 | 3 7/8" | 0000000 | 00000 |
1 1/4" | 1 3/8" | 120 | 600 psi @ 100° F | 150 psi @ 365° F | -20° to 450° | 29 | 4 3/4" | 0000000 | 000000 |
1 1/2" | 1 5/8" | 170 | 600 psi @ 100° F | 150 psi @ 365° F | -20° to 450° | 29 | 5 1/4" | 0000000 | 000000 |
2" | 2 1/8" | 376 | 600 psi @ 100° F | 150 psi @ 365° F | -20° to 450° | 29 | 6 1/16" | 0000000 | 000000 |
Solder these valves to metal tubing for a permanent, leak-tight connection. They meet NSF/ANSI 61 for use with drinking water.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Tube | ||||||||
---|---|---|---|---|---|---|---|---|
ID | OD | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | End-to-End Lg. | Each | |
Brass Body | ||||||||
Solder Connect × Solder Connect | ||||||||
1/2" | 5/8" | 46 | 500 psi @ 100° F | -50° to 250° | 29.9 | 2 1/4" | 0000000 | 000000 |
3/4" | 7/8" | 66 | 500 psi @ 100° F | -50° to 250° | 29.9 | 2 7/8" | 0000000 | 00000 |
1" | 1 1/8" | 93 | 500 psi @ 100° F | -50° to 250° | 29.9 | 3 3/8" | 0000000 | 00000 |
1 1/2" | 1 5/8" | 290 | 400 psi @ 100° F | -50° to 250° | 29.9 | 4 1/2" | 0000000 | 00000 |
2" | 2 1/8" | 420 | 400 psi @ 100° F | -50° to 250° | 29.9 | 5 7/16" | 0000000 | 00000 |
Slide copper pipe into the solder-connect fittings on these valves and weld for a strong, permanent connection. They’re often used for remote on/off control in heating and cooling systems. All operate on electricity to automatically start and stop flow. Valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. They are normally closed unless actuated. All are standard port, so they slightly restrict flow.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. The manual override allows you to operate the valve during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | For Copper Tube Size | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Each | |
Brass Body with Wire Leads | ||||||||||||
24V AC | ||||||||||||
5/8" | 1/2 | 4 | 300 psi @ 250° F | 15 psi @ 250° F | Pressure Drop Assisted | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 0000000 |
7/8" | 3/4 | 4 | 300 psi @ 250° F | 15 psi @ 250° F | Pressure Drop Assisted | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
1 1/8" | 1 | 4 | 300 psi @ 250° F | 15 psi @ 250° F | Pressure Drop Assisted | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
120V AC | ||||||||||||
5/8" | 1/2 | 3 | 300 psi @ 250° F | 15 psi @ 250° F | Pressure Drop Assisted | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
7/8" | 3/4 | 3 | 300 psi @ 250° F | 15 psi @ 250° F | Pressure Drop Assisted | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
1 1/8" | 1 | 3 | 300 psi @ 250° F | 15 psi @ 250° F | Pressure Drop Assisted | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
Attach these balancing valves using solder—they help you measure the difference in pressure across the valve and adjust the flow rate to system components. Also known as circuit setters, they’re often used in systems that need an even distribution of flow, such as HVAC systems. To check what percentage they’re open, there’s an arrow on these valves that’s connected to their measuring plate. There are readout ports on both sides for connecting flow measurement tools, such as pressure gauges and probes, which help you track how much the valves reduce flow. Use the memory shutoff function to open them to a saved setting.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Tube OD | Flow Coefficient (Cv) | Maximum Pressure | Temperature Range, °F | End-to-End Length | Stem Type | Each | |
Brass Body | |||||||
---|---|---|---|---|---|---|---|
Solder Connect × Solder Connect | |||||||
1/2" | 0.68 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 2 15/16" | Nonrising | 0000000 | 0000000 |
1/2" | 1.75 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 2 15/16" | Nonrising | 0000000 | 000000 |
3/4" | 0.75 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 3 9/16" | Nonrising | 0000000 | 000000 |
3/4" | 3.4 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 3 9/16" | Nonrising | 0000000 | 000000 |
1" | 5.75 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 4 5/16" | Nonrising | 0000000 | 000000 |
1 1/4" | 12.5 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 4 15/16" | Nonrising | 0000000 | 000000 |
1 1/2" | 19.9 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 5 1/4" | Nonrising | 0000000 | 000000 |
2" | 40 | 200 psi @ 250° F, 250 psi @ 225° F, 300 psi @ 200° F | 0° to 250° | 6 5/16" | Nonrising | 0000000 | 000000 |