    86 Products

    Gas Chimney Vent Pipe and Fittings

    For use with gas-fired equipment, such as boilers and furnaces, these vent pipes and fittings withstand temperatures up to 400° F. Also known as type B gas vents.
    To join pipes and connectors, insert a male end into a female end and secure with the included locking band.
    Pipes
    Image of Product. Front orientation. Chimney Pipe and Fittings. Gas Chimney Vent Pipe and Fittings, Pipes.
    Galvanized Steel
    Chimney
    Pipe Size
    Female
    ID
    Male
    OD
    Lg.
    Ga.
    Construction
    Inner Wall
    Material
    Certification
    Each
    Female × Male
    44"4 1/2"18"28Double WallAluminum
    UL Listed
    2117K12000000
    55"5 1/2"18"28Double WallAluminum
    UL Listed
    2117K1300000
    66"6 1/2"18"28Double WallAluminum
    UL Listed
    2117K1400000
    77"8"18"28Double WallAluminum
    UL Listed
    2117K1500000
    88"9"18"28Double WallAluminum
    UL Listed
    2117K1600000
     
    Adjustable-Angle Connectors, 45° Elbow to Straight
    Image of Product. Front orientation. Chimney Pipe and Fittings. Gas Chimney Vent Pipe and Fittings, Adjustable-Angle Connectors, 45° Elbow to Straight.
    Adjustable-angle elbow connectors can be used at an angle or straight.
    Galvanized Steel
    Chimney
    Pipe Size
    Female
    ID
    Male
    OD
    Ga.
    Construction
    Inner Wall
    Material
    Certification
    Each
    Female × Male
    77"8"28Double WallAluminum
    UL Listed
    2117K25000000
    88"9"28Double WallAluminum
    UL Listed
    2117K2600000
     
    Adjustable-Angle Connectors, 60° Elbow to Straight
    Image of Product. Front orientation. Chimney Pipe and Fittings. Gas Chimney Vent Pipe and Fittings, Adjustable-Angle Connectors, 60° Elbow to Straight.
    Adjustable-angle elbow connectors can be used at an angle or straight.
    Galvanized Steel
    Chimney
    Pipe Size
    Female
    ID
    Male
    OD
    Ga.
    Construction
    Inner Wall
    Material
    Certification
    Each
    Female × Male
    44"4 1/2"28Double WallAluminum
    UL Listed
    2117K27000000
    55"5 1/2"28Double WallAluminum
    UL Listed
    2117K2800000
    66"6 1/2"28Double WallAluminum
    UL Listed
    2117K2900000
     
    Tee Connectors
    Image of Product. Front orientation. Chimney Pipe and Fittings. Gas Chimney Vent Pipe and Fittings, Tee Connectors.
    Galvanized Steel
    Chimney
    Pipe Size
    Female
    ID
    Male
    OD
    Ga.
    Construction
    Inner Wall
    Material
    Certification
    Each
    Female × Female × Male
    44"4 1/2"28Double WallAluminum
    UL Listed
    2117K32000000
    55"5 1/2"28Double WallAluminum
    UL Listed
    2117K3300000
    66"6 1/2"28Double WallAluminum
    UL Listed
    2117K3400000
    88"9"28Double WallAluminum
    UL Listed
    2117K36000000
     
    Roof Flashings
    Image of Product. Front orientation. Chimney Pipe and Fittings. Gas Chimney Vent Pipe and Fittings, Roof Flashings.
    Roof flashing requires a storm collar (sold separately).
    Steel
    Chimney
    Pipe Size
    ID
    For Max.
    Roof Pitch
    Ga.
    Each
    44 1/2"6/12282117K52000000
    55 1/2"6/12282117K5300000
    66 1/2"6/12282117K5400000
    78"6/12282117K5500000
    89"6/12282117K5600000
     
    Storm Collars
    Image of Product. Front orientation. Chimney Pipe and Fittings. Gas Chimney Vent Pipe and Fittings, Storm Collars.
    Steel
    Chimney
    Pipe Size
    ID
    Ga.
    Each
    44 1/2"282117K6200000
    55 1/2"282117K6300000
    66 1/2"282117K6400000
    78"282117K6500000
    89"282117K6600000
     

    Breather Vents

    Image of Product. Style A. Front orientation. Style A. Breather Vents.
    Image of Product. Style D. Front orientation. Style D. Breather Vents.
    Image of Product. Style E. Front orientation. Style E. Breather Vents.

    Style A

    Style D

    Style E

    Protect against excess vacuum and pressure in cylinders, gear boxes, enclosures, manifolds, and tanks. You can also use these breather vents to block debris from entering equipment.
    Splash Guard—Breather vents with splash guard are good for containers that are often filled and drained; they have a guard that prevents oil from splashing out of the vent hole.
    Style
    Pipe
    Size
    Max. Flow Rate
    @ Pressure
    Max.
    Pressure
    Max. Temp.,
    ° F
    Ht.
    For Use With
    Removes Particle
    Size Down To, μm
    Features
    Each
    NPT Male
     
    Zinc-Plated Steel Body and Fitting
    A2
    1,095 scfm @ 100 psi150 psi3001 5/8"Air, Inert Gas909833K16000000
    D1/8
    Not RatedNot Rated2251"Air, Inert Gas, Oil, Water402257K1100000
    D1/4
    Not RatedNot Rated2251"Air, Inert Gas, Oil, Water402257K1200000
    D3/8
    Not RatedNot Rated2251 1/16"Air, Inert Gas, Oil, Water402257K1300000
    D1/2
    Not RatedNot Rated2251 3/16"Air, Inert Gas, Oil, Water402257K1400000
    D3/4
    Not RatedNot Rated2251 1/4"Air, Inert Gas, Oil, Water402257K1500000
    E1/8
    Not RatedNot Rated2251 3/16"Air, Inert Gas, Oil, Water40Splash Guard2257K3100000
    E1/4
    Not RatedNot Rated2251 3/16"Air, Inert Gas, Oil, Water40Splash Guard2257K3200000
    E3/8
    Not RatedNot Rated2251 1/4"Air, Inert Gas, Oil, Water40Splash Guard2257K3300000
    E1/2
    Not RatedNot Rated2251 5/16"Air, Inert Gas, Oil, Water40Splash Guard2257K3400000
    E3/4
    Not RatedNot Rated2251 3/8"Air, Inert Gas, Oil, Water40Splash Guard2257K3500000
     
    Nickel-Plated Steel Body and Fitting
    A1/8
    2 scfm @ 100 psi150 psi3007/16"Air, Inert Gas409833K210000
    A1/4
    3 scfm @ 100 psi150 psi3005/8"Air, Inert Gas409833K220000
    A3/8
    7 scfm @ 100 psi150 psi3003/4"Air, Inert Gas409833K230000
    A1/2
    17 scfm @ 100 psi150 psi3007/8"Air, Inert Gas409833K110000
    A3/4
    20 scfm @ 100 psi150 psi3001"Air, Inert Gas409833K120000
    A1
    28 scfm @ 100 psi150 psi3001 5/16"Air, Inert Gas409833K130000
    A1 1/4
    50 scfm @ 100 psi150 psi3001 7/16"Air, Inert Gas409833K1400000
    A1 1/2
    73 scfm @ 100 psi150 psi3001 1/2"Air, Inert Gas409833K1500000
     
    BSPT Male
     
    Zinc-Plated Steel Body and Fitting
    A1/8
    26 scfm @ 100 psi150 psi3007/16"Air, Inert Gas909847K110000
    A1/4
    35 scfm @ 100 psi150 psi30011/16"Air, Inert Gas909847K120000
    A3/8
    87 scfm @ 100 psi150 psi30013/16"Air, Inert Gas909847K130000
    A1/2
    131 scfm @ 100 psi150 psi3001"Air, Inert Gas909847K140000
    A3/4
    219 scfm @ 100 psi150 psi3001 1/16"Air, Inert Gas909847K150000
     
    NPSM Female
     
    Zinc-Plated Steel Body and Fitting
    F1/8
    26 scfm @ 100 psi150 psi3005/8"Air, Inert Gas909833K240000
    F1/4
    35 scfm @ 100 psi150 psi3003/4"Air, Inert Gas909833K250000
    F3/8
    87 scfm @ 100 psi150 psi30015/16"Air, Inert Gas909833K260000
    F1/2
    131 scfm @ 100 psi150 psi3001"Air, Inert Gas909833K270000
     

    Weather Resistant Breather Vents

    Image of Product. Front orientation. Breather Vents. Weather Resistant Breather Vents, Threaded NPT Male, Style A.
    Image of Product. Front orientation. Breather Vents. Weather Resistant Breather Vents, Slip On Female, Style C.

    Threaded

    NPT Male,

    Style A

    Slip On Female

    Style C

    Shield outdoor pipe and tank openings from the environment. Also known as vent caps, these breather vents have screens to allow air flow while blocking debris. Use them to prevent excess vacuum and pressure in your equipment.
    Threaded NPT Male
    Image of Product. Front orientation. Breather Vents. Weather Resistant Breather Vents, Threaded NPT Male, Style A.

    Style A

    Screen
    Style
    Pipe
    Size
    Max. Flow Rate
    @ Pressure
    Max.
    Pressure
    Max.
    Temp.
    Ht.
    Dia.
    For Use
    With
    Material
    Construction
    Mesh
    Size
    Removes Particle
    Size Down To, μm
    Each
    Zinc-Plated Steel Body and Fitting
    A3/8
    Not RatedNot RatedNot Rated1 1/4"1 1/4"Air304 Stainless Steel
    Wire Mesh100 × 100
    14036635K38000000
    A1/2
    Not RatedNot RatedNot Rated1 7/16"1 1/4"Air304 Stainless Steel
    Wire Mesh100 × 100
    14036635K3900000
     
    Slip On Female
    Image of Product. Front orientation. Breather Vents. Weather Resistant Breather Vents, Slip On Female, Style C.

    Style C

    Style C—Style C has a set screw to secure in place.
    Screen
    Style
    Pipe
    Size
    Max. Flow Rate
    @ Pressure
    Max.
    Pressure
    Max.
    Temp.
    Ht.
    Dia.
    For Use
    With
    Material
    Construction
    Screen Opening
    Size
    Features
    Each
    Zinc-Plated Steel Body and Fitting
    C1
    Not RatedNot RatedNot Rated1 1/2"2 1/2"AirSteelPerforated1/8"Set Screw36635K5100000
    C1 1/4
    Not RatedNot RatedNot Rated1 1/2"2 1/2"AirSteelPerforated1/8"Set Screw36635K520000
    C1 1/2
    Not RatedNot RatedNot Rated1 3/4"2 3/4"AirSteelPerforated1/8"Set Screw36635K530000
    C2
    Not RatedNot RatedNot Rated2 3/4"4"AirSteelPerforated1/8"Set Screw36635K5400000
     

    High-Temperature Chimney Vent Pipe and Fittings

    Built to withstand temperatures up to 1000° F, these vent pipes and fittings are for use with boilers, furnaces, stoves, and other equipment that is fired by gas, oil, wood, or coal.
    To join pipes and connectors, twist a male end into a female end and secure with the included locking band.
    Roof Flashings
    Image of Product. Front orientation. Chimney Pipe and Fittings. High-Temperature Chimney Vent Pipe and Fittings, Roof Flashings.
    Aluminum Zinc
    Alloy-Coated Steel
    Chimney
    Pipe Size
    For Max.
    Roof Pitch
    Ga.
    Includes
    Each
    66/1228Storm Collar1716K7110000000
    86/1228Storm Collar1716K8000000
    106/1228Storm Collar1716K9000000
     
    Storm Collars
    Image of Product. Front orientation. Chimney Pipe and Fittings. High-Temperature Chimney Vent Pipe and Fittings, Storm Collars.
    Aluminum Zinc
    Alloy-Coated Steel
    Chimney
    Pipe Size
    Ga.
    Each
    6281716K96000000
    8281716K9700000
    10281716K9800000
     

    Breather Vents with Cap

    Image of Product. Front orientation. Breather Vents. Breather Vents with Cap, Style A.
    Image of Product. Front orientation. Breather Vents. Breather Vents with Cap, Style C.
    Image of Product. Replacement Screen. Front orientation. Breather Vent Screens. Breather Vents with Cap, Style C.

    Style A

    Style C

    Replacement Screen

    Add a filling port to your hydraulic tank while protecting against excess pressure and vacuum. Breather vents stop debris from entering your tank. Mount them on top of standard tank openings with included hardware.
    Style A
    Image of Product. Front orientation. Breather Vents. Breather Vents with Cap, Style A.
    Image of Product. Replacement Screen. Front orientation. Breather Vent Screens. Breather Vents with Cap, Style A.

    Replacement Screen

    Vents
    Replacement
    Screens
    For Opening
    Dia.
    Max. Flow
    Rate, gpm
    Max. Temp.,
    ° F
    Ht.
    For Use
    With
    Screen Material
    Mount
    Type
    No. of Bolt
    Holes
    Bolts
    Included
    Removes Particle
    Size Down To, μm
    Each
    Each
    Steel Body
     
    304 Stainless Steel Cap
    2 1/8"202205"Air, Oil304 Stainless Steel
    Flange6Yes404473K210000004473K32000000
     
    Steel Cap
    2 1/8"1922505 1/8"Air, Oil304 Stainless Steel
    Flange6Yes404473K22000004473K330000
     
    Style C
    Image of Product. Front orientation. Breather Vents. Breather Vents with Cap, Style C.
    Image of Product. Replacement Screen. Front orientation. Breather Vent Screens. Breather Vents with Cap, Style C.

    Replacement Screen

    Vents
    Replacement
    Screens
    For Opening
    Dia.
    Max. Flow
    Rate, gpm
    Max.
    Temp.
    Ht.
    For Use
    With
    Screen Material
    Mount
    Type
    No. of Bolt
    Holes
    Bolts
    Included
    Removes Particle
    Size Down To, μm
    Each
    Each
    Steel Body
     
    304 Stainless Steel Cap
    2 1/8"20220° F5 3/4"Air, OilNylon
    Flange6Yes404473K140000004473K31000000
     
    Steel Cap
    2 1/8"115Not Rated5 1/8"Air, Oil304 Stainless Steel
    Flange6Yes104473K152000004473K330000
    2 1/8"115Not Rated6 1/8"Air, OilNylon
    Flange6Yes104473K151000004473K1490000
    2 1/8"190150° F6 1/8"Air, OilNylon
    Flange6Yes404473K53000004473K1490000
     

    Lockable Breather Vents with Cap

    Secure access to vented openings in pipe and tanks—the cap can be locked to prevent tampering. These breather vents allow you to add a filling port to your hydraulic tank while protecting against excess pressure and vacuum. Use them to stop debris from entering your tank. Breather vents mount on top of standard tank openings with included hardware. Padlock is not included.
    Flange Mount
    Image of Product. Steel with 304 Stainless Steel Screen. Front orientation. Breather Vents. Lockable Breather Vents with Cap, Flange Mount.
    Image of Product. Steel with Nylon Plastic Screen. Front orientation. Breather Vents. Lockable Breather Vents with Cap, Flange Mount, Nylon Screen.

    Steel with 304

    Stainless Steel

    Screen

    Steel with

    Nylon Plastic

    Screen

    For Opening
    Dia.
    Max.
    Pressure
    Ht.
    For Use
    With
    Cap
    Material
    Screen Material
    No. of Bolt
    Holes
    Bolts
    Included
    Removes Particle
    Size Down To, μm
    For Max. Padlock
    Shackle Dia.
    Each
    Steel Body
    2 1/8"Not Rated5 1/8"Air, OilSteel304 Stainless Steel
    6Yes103/8"3853N13000000
    2 1/8"Not Rated5 1/8"Air, OilSteel304 Stainless Steel
    6Yes403/8"4473K4500000
    2 1/8"Not Rated6 1/8"Air, OilSteelNylon
    6Yes103/8"3853N1200000
    2 1/8"Not Rated6 1/8"Air, OilSteelNylon
    6Yes403/8"3853N1100000
     

    Moisture Absorbing Breather Vents

    Keep moisture, dirt, and debris from entering your oil reservoirs. The silica gel inside these breather vents absorbs moisture from the air, preventing rust from forming inside your tanks. The gel changes from blue to pink as it becomes saturated, letting you know it needs to be replaced. A second filter blocks dust and other particles from getting inside. These breather vents allow air to flow in and out of your lubrication system, keeping excess vacuum or pressure from building up in cylinders, gear boxes, and tanks.
    Steel Body—NPT Male
    Image of Product. Front orientation. Breather Vents. Moisture Absorbing Breather Vents, Steel Body—NPT Male.
    Image of Product. Front orientation. Breather Vent Repair Kits. Moisture Absorbing Breather Vents.

    Repair Kits

    For an extended service life, use breather vents with a steel body. They are stronger than breather vents with plastic bodies and hold up better when exposed to chemicals. A window lets you check the color of the gel.
    Repair Kits—No need to replace the entire unit when the gel is saturated—use rebuild kits to add fresh gel and to replace the window, filters, and gaskets.
    Vents
    Repair Kits
    Pipe
    Size
    For Tank Cap.,
    gal.
    Max. Flow Rate
    @ Pressure
    Max. Temp.,
    ° F
    Ht.
    Dia.
    For Use
    With
    Removes Particle
    Size Down To, μm
    Each
    Each
    Steel Body
    2
    1 to 80085 scfm @ 1 psi22011 1/2"10 1/8"Air13297T770000000003297T7710000000
    2
    1 to 1,30085 scfm @ 1 psi22013 3/4"10 1/8"Air13297T78000000003297T781000000
    2
    1 to 2,40080 scfm @ 1 psi22018 1/4"10 1/8"Air13297T79000000003297T791000000
    3
    1 to 4,000205 scfm @ 1 psi22019 1/4"15 1/2"Air13297T81000000003297T811000000
     
    back to top