    Hazardous Location Enclosed Lever Switches

    Image of Product. Front orientation. Lever Switches. Hazardous Location Enclosed Lever Switches.
    Use these switches where ignitable gas, dust, and fibers may be present. They're UL and C-UL listed for hazardous locations.
    Mounting
    Actuator
    Color
    Message (Switch Position)
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Enclosure
    Rating
    Each
    3 Positions
     
    Screw-Terminal Wire Connection
    GrayHand (Left), Off (Center), Auto (Right)21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    10 amp @ 120V AC600No25/16"NEMA 3
    6883K630000000
     

    Hazardous Location Pressure Switches

    Image of Product. Style A. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style A.
    Image of Product. Style B. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style B.

    Style

    A

    Style B

    Built with an explosion-proof enclosure to meet NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL and CSA for use where explosive liquids, dust, and gas are present. When they reach the set pressure, they power equipment, signal controls, or trigger alarms. They’re single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). In addition to being UL listed and CSA certified, these switches are CE marked, so they also meet European safety standards.
    All switches are IP and NEMA rated for use outdoors and protection from some corrosion, dust, and spraying water.
    Wire Lead Connection
    Image of Product. Style A. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style A.
    Image of Product. Style B. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style B.

    Style

    A

    Style B

    IP67 Enclosure Rating and NEMA 4X Enclosure Rating—IP67 and NEMA 4X rated switches seal out water from temporary submersion and have increased protection against corrosion, similar to 304 stainless steel.
    Style
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    Internal Adjustment
    A8 to 605601,000±5%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K710000000
    A10 to 10091001,000±5%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K72000000
    A20 to 200162001,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K73000000
    A50 to 500605005,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K74000000
    A100 to 1,000871,0005,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K75000000
    A200 to 2,0001652,0005,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K76000000
     
    1/2 Threaded NPT Female Pipe
     
    Internal Adjustment
    B6 to 302301,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K61000000
    B12 to 602601,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K62000000
    B20 to 1003.51001,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K63000000
    B40 to 2006.52001,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K64000000
    B80 to 400114001,600±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K65000000
     

    Hazardous Location Enclosed Push-Button Switches

    Image of Product. Front orientation. Push-Button Switches. Hazardous Location Enclosed Push-Button Switches, 1 Flush Push Button.
    Image of Product. Front orientation. Push-Button Switches. Hazardous Location Enclosed Push-Button Switches, 1 Mushroom Push Button.
    Image of Product. Front orientation. Push-Button Switches. Hazardous Location Enclosed Push-Button Switches, 1 Flush Push Button and 1 Projecting Push Button.

    1 Flush Push Button

    1 Mushroom Push Button

    1 Flush Push

    Button and 1

    Projecting Push

    Button

    Image of Specification. Front orientation. Contains Border. Start. Hazardous Location Enclosed Push-Button Switches.

    Start

    Image of Specification. Front orientation. Contains Border. Stop. Hazardous Location Enclosed Push-Button Switches.

    Stop

    Use these switches where ignitable gas and dust may be present. They're rated for use in hazardous locations.
    Mounting
    Message (Actuator Color)
    No. of Circuits
    Controlled per Button
    Switch Starting
    Position
    Switch
    Action
    No. of Terminals
    per Button
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Conduit
    Trade Size
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Enclosure Rating
    Each
    Aluminum Housing with Screw-Terminal Wire Connection
     
    1 Flush Push Button
    Start (Black)11 Off and 1 On
    Momentary
    4DPST-1NO/1NC
    10 amp @ 120V AC6003/4
    No25/16"NEMA 3, NEMA 7, NEMA 9
    6883K610000000
     
    1 Mushroom Push Button
    Stop (Red)11 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    10 amp @ 120V AC6003/4
    No23/16"NEMA 3
    6883K62000000
     
    1 Flush Push Button and 1 Projecting Push Button
    Start (Green), Stop (Red),21 Off and 1 On
    Momentary
    2DPST-1NO/1NC
    10 amp @ 120V AC6003/4
    No29/32"NEMA 3, NEMA 7, NEMA 9
    6883K55000000
     

    Hazardous Location Enclosed Motor Switches

    Image of Product. Front orientation. Motor Switches. Hazardous Location Enclosed Motor Switches.
    Safely turn motors on and off near ignitable gases and dust—the housing on these switches seals in anything that could ignite flammable material. Made from aluminum, the housing is lightweight and durable. It guards against water, oil, and other materials that could cause damage. Even in harsh conditions, there’s no need to mount these switches inside an electrical panel.
    You need to grip and twist the lever to actuate these switches, so they won’t accidentally turn on or off if something bumps into them. In addition to starting and stopping motors, they work with other circuits, such as lighting and electric heat circuits. They don’t provide overload protection.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    Wire
    Connection
    Environment
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    2Single (3 hp @ 240V AC)2 Off
    DPST-NO
    30600Painted Aluminum6.5"3"Screw TerminalHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    UL Listed, C-UL Listed, CSA Certified
    7657K320000000
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    30600Painted Aluminum6.5"3"Screw TerminalHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    UL Listed, C-UL Listed, CSA Certified
    7657K22000000
     

    Hazardous Location Limit Switches

    Image of Product. Front orientation. Contains Annotated. Limit Switches. Hazardous Location Limit Switches, Plunger Actuator.
    Image of Product. Front orientation. Contains Annotated. Limit Switches. Hazardous Location Limit Switches, Wobble Stick Actuator.

    Plunger Actuator

    Wobble Stick

    Actuator

    Safely open or close a circuit near ignitable gases and dust—the housing on these switches seals in anything that could ignite flammable material. You'll know they're safe because they're NEC Class I, Divisions 1, 2 Groups B, C, and D; and Class II, Divisions 1, 2 Groups E, F, and G certified for hazardous locations. These switches send a signal to your circuit when an object hits the actuator—for instance, a box on a conveyor runs into the switch, stopping the conveyor. They open and close circuits as fast as snap-acting switches, but they have a bigger actuator for large objects.
    Plunger Actuator—Switches with a plunger actuator let you adjust the actuator’s height to easily align it with your target. They require a push to activate, similar to a button.
    Wobble Stick Actuator—Switches with a wobble stick actuator have an arm that rotates 360°, so you don’t need to align it in a specific direction. The actuator won’t snap if pushed backward, such as if there’s a jam in your system.
    Housing
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Actuation Torque,
    in·ozf
    Operating
    Temp. Range, ° F
    Actuator
    Ht.
    No. of
    Terminals
    Lg.
    Ht.
    Dp.
    Housing
    Material
    Conduit
    Trade Size
    Enclosure Rating
    Each
    Plunger Actuator
     
    Screw-Terminal Wire Connection
    11 Off or 1 On
    Momentary
    SPDT
    10 amp @ 600V AC, 2.5 amp @ 600V DC600V AC
    600V DC
    0 to 1852.7" to 2.9"42.7"4.1"2.1"Aluminum1/2
    NEMA 6P, NEMA 7, NEMA 9, NEMA 13
    7794K140000000
     
    Wobble Stick Actuator
     
    Screw-Terminal Wire Connection
    11 Off or 1 On
    Momentary
    SPDT
    10 amp @ 600V AC, 2.5 amp @ 600V DC600V AC
    600V DC
    480 to 1856.2"42.7"4.1"2.1"Aluminum1/2
    NEMA 6P, NEMA 7, NEMA 9, NEMA 13
    7794K15000000
     

    Hazardous Location 30 mm Multifunction Panel-Mount Push-Button Switches

    Image of Product. Black. Front orientation. Push-Button Switches. Hazardous Location 30 mm Multifunction Panel-Mount Push-Button Switches.
    Image of Product. Green/Red. Front orientation. Push-Button Switches. Hazardous Location 30 mm Multifunction Panel-Mount Push-Button Switches.

    Black

    Green/Red

    Rated NEC Classes I, II, and III, these switches have a housing that keeps fire and sparks in, so they won’t ignite gases, vapors, or dust. To save space on your panel, they can control multiple circuits. Install them in a standard panel cutout.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Buttons
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    For Max.
    Panel Thk.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure
    Rating
    Choose an Actuator
    Color
    Each
    Metal Actuator Base with Screw-Terminal Wire Connection—Not Illuminated (600V AC/250V DC Maximum Voltage)
     
    Flush
    22 Off
    2Maintained
    4DPST-NO
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"4 1/8"4NEMA 4X
    Green/Red8828N170000000
    21 Off and 1 On
    2Momentary
    4DPST-1NO/1NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"3 3/4"4NEMA 4X
    Black, Green/Red8828N11000000
    22 On
    2Maintained
    4DPST-NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"4 1/8"4NEMA 4X
    Green/Red8828N18000000
    42 Off and 2 On
    2Momentary
    84PST-2NO/2NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"3 3/4"4NEMA 4X
    Black, Green/Red8828N14000000
     
    Blocks

    Hazardous Location Enclosed Disconnect Switches

    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    Powder-Coated Aluminum Housing—Made from aluminum, these switches also resist corrosion in wet or oily areas.
    Lockout—Switches have a lockout, so you can secure them in the off position with a padlock (not included).
    Hazardous Location Rating—They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Hazardous Location Rating
    Enclosure Rating
    Certification
    Each
    Gray Powder-Coated Aluminum Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    A306003PST
    Three (30 hp @ 600V AC)8 1/16"5 3/4"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N11000000000
     
    Gray Powder-Coated Aluminum Housing with Yellow Actuator
     
    3 Circuits Controlled with Lockout
    B606003PST
    Three (40 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1200000000
    B1006003PST
    Three (50 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1300000000
     

    Speed-Monitoring Switches

    Image of System. Front orientation. Contains Annotated. Speed-Monitoring Switches. Speed-Monitoring Switches.
    Image of Product. Front orientation. Contains Annotated. Speed-Monitoring Switches. Speed-Monitoring Switches.
    Detect unwanted slowdowns in a rotary shaft that could cause machine damage and downtime. These switches are often used on drivetrains, conveyors, and other power-driven components. They come with a pulser disc, which you’ll need to attach to the shaft by drilling and tapping a hole. Once mounted, the disc rotates with the shaft and creates magnetic signals that the switch senses. When the speed falls below a set point, the switch will trigger an alarm or turn off the system.
    Switches are UL listed and rated NEC Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. They have an explosion-proof housing and are also rated NEMA 4X for washdown and corrosion protection.
    Switching
    Input
    Conduit
    Mounting
    Slot
    Activation
    Point Range, rpm
    Current,
    amp
    Voltage,
    V AC
    Voltage,
    V AC
    Freq.,
    Hz
    No. of
    Terminals
    Trade
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    No.
    of
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Housing
    Material
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    1 Off (Normally Open), 1 On (Normally Closed) Starting Switch Position
     
    SPDT
    5 to 10051201206051
    NPT
    Female1 1/4"0.32"24.4"3.7"4.8"YesAluminum
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    6177K110000000
     

    Hazardous Location Vibration Switches

    Image of Product. Front orientation. Contains Annotated. Vibration Switches. Hazardous Location Vibration Switches.
    Get NEMA 4 and IP66 protection from dirt and water. These switches are rated for hazardous locations for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. If vibration or shock exceeds a set activation point, the contacts actuate to either shut down your machine or activate an alarm. Reset the switch with the push of a button. The activation point is adjustable between 0 to 5 gravity units (g) at 0 to 60 Hz.
    Activation
    Point
    Switching
    Housing
    Conduit
    Mounting
    Slot
    Range,
    g
    Freq. Range,
    Hz
    Current,
    amp
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Trade
    Size
    Thread
    Type
    Gender
    Mounting Fasteners
    Included
    No. of Mounting
    Holes
    Lg.
    Wd.
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    1 Off or 1 On Switch Starting Position
     
    SPDT
    0 to 50 to 6015125
    480
    4.2"4 3/4"6"-40 to 1553/4
    NPT
    FemaleNo43/4"3/8"NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP66
    NEMA 4
    UL Listed, C-UL Listed, CSA-US Certified, CSA Certified, CE Marked
    1188T310000000
     

    Hazardous Location Rotatable DC Metallic-Object Proximity Sensors

    Image of Product. Front orientation. Proximity Sensors. Hazardous Location Rotatable DC Metallic-Object Proximity Sensors.
    Image of Specification. 4-Pole M12 Plug. Front orientation. Proximity Sensors. Hazardous Location Rotatable DC Metallic-Object Proximity Sensors.
    Image of Specification. Front orientation. Flush Mount. Hazardous Location Rotatable DC Metallic-Object Proximity Sensors.

    4-Pole

    M12

    Plug

    Flush Mount

    Image of Specification. Front orientation. Projecting Mount. Hazardous Location Rotatable DC Metallic-Object Proximity Sensors.

    Projecting Mount

    Twist the sensor to detect metallic objects where explosive dust or gas may be present—the sensor rotates for front, side, top, or bottom sensing. These sensors are UL and C-UL listed as well as ATEX and IECEx certified for hazardous locations. Their NAMUR signal produces low current and low voltage, so they won’t spark or ignite. You must connect them to a barrier (sold separately), which reduces the current and voltage that enters your hazardous area.
    Because you can rotate the sensor, these make good replacements for limit switches with actuators that could break when hit. They’re often known as inductive proximity sensors and detect objects even if they’re covered by water, oil, dirt, or a surface finish. Sensing distance is based on the type of material that’s sensed; the distance listed is for mild steel. Send signals from these sensors to programmable logic controllers (PLCs) to support automated processes.
    These sensors have a 4-pole M12 plug that connects to cables with a socket (sold separately), so you can quickly connect and disconnect them. You can also check on them from any angle, thanks to LED status indicators on their corners. All are CE marked for safety.
    To view wiring diagrams, select a part number and click Product Detail.
    IP rated, all sensors seal out dust and water from high-pressure washdowns.
    IP67 Enclosure Rating and IP68 Enclosure Rating—IP67- and IP68-rated sensors withstand some submersion.
    Flush Mount—Flush sensors, also called embeddable and shielded sensors, are more accurate than projecting sensors at close range. They also won’t interfere with each other’s signals when installed close together. Their sensor face mounts evenly with any material, including metal.
    Projecting Mount—Projecting sensors, also known as non-embeddable and unshielded sensors, sense objects farther away than flush sensors. But, the area around the sensor must be metal free.
    Switch Starting
    Position
    Max. Sensing
    Distance, mm
    Output Digital
    Signal
    Input Voltage
    Current
    Output
    Electrical
    Connection Type
    Lg.,
    mm
    Wd.,
    mm
    Ht.,
    mm
    Circuit Protection
    Features
    Temp. Range,
    ° F
    Hazardous Location Rating
    Certification
    Each
    Plastic Housing (IP66, IP69K)
     
    Flush with 4-Pole M12 Plug Connection
    1 On
    20NAMUR8V DC to 8.5V DC10 mAPlug In674040Reverse Polarity
    Short Circuit
    LED Power Indicator, LED Status Indicator, Rotatable Sensor-10 to 210ATEX II 1 D Ex Ia IIIC T135° C Da; ATEX II 1 G Ex Ia IIC T6...T1 Ga; ATEX II 2 G Ex Ia IIC T6...T1 Gb; IEC Zone 0 Groups IIC, IIB, IIA; IEC Zone 20 Groups IIIC, IIIB, IIIA; IECEx Ex Ia I Mb; IECEx Ex Ia IIC T6...T1 Ga; IECEx Ex Ia IIC T6...T1 Gb; IECEx Ex Ia IIIC T135° C Da; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2C-UL Listed, CE Marked, UL Listed
    7104N120000000
     
    Plastic Housing (IP67, IP69K)
     
    Flush with 4-Pole M12 Plug Connection
    1 On
    20NAMUR8V DC to 8.5V DC10 mAPlug In1184040Reverse Polarity
    Short Circuit
    LED Power Indicator, LED Status Indicator, Rotatable Sensor-10 to 210ATEX II 1 D Ex Ia IIIC T135° C Da; ATEX II 1 G Ex Ia IIC T6...T1 Ga; ATEX II 2 G Ex Ia IIC T6...T1 Gb; IEC Zone 0 Groups IIC, IIB, IIA; IEC Zone 20 Groups IIIC, IIIB, IIIA; IECEx Ex Ia I Mb; IECEx Ex Ia IIC T6...T1 Ga; IECEx Ex Ia IIC T6...T1 Gb; IECEx Ex Ia IIIC T135° C Da; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2C-UL Listed, CE Marked, UL Listed
    6305N111000000
     
    Plastic Housing (IP69K)
     
    Projecting with 4-Pole M12 Plug Connection
    1 On
    40NAMUR8V DC to 8.5V DC10 mAPlug In674040Reverse Polarity
    Short Circuit
    LED Power Indicator, LED Status Indicator, Rotatable Sensor-10 to 210ATEX II 1 D Ex Ia IIIC T135° C Da; ATEX II 1 G Ex Ia IIC T6...T1 Ga; ATEX II 2 G Ex Ia IIC T6...T1 Gb; IEC Zone 0 Groups IIC, IIB, IIA; IEC Zone 20 Groups IIIC, IIIB, IIIA; IECEx Ex Ia I Mb; IECEx Ex Ia IIC T6...T1 Ga; IECEx Ex Ia IIC T6...T1 Gb; IECEx Ex Ia IIIC T135° C Da; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2C-UL Listed, CE Marked, UL Listed
    7104N13000000
     
    Plastic Housing (IP68, IP69K)
     
    Projecting with 4-Pole M12 Plug Connection
    1 On
    40NAMUR8V DC to 8.5V DC10 mAPlug In1184040Reverse Polarity
    Short Circuit
    LED Power Indicator, LED Status Indicator, Rotatable Sensor-10 to 210ATEX II 1 D Ex Ia IIIC T135° C Da; ATEX II 1 G Ex Ia IIC T6...T1 Ga; ATEX II 2 G Ex Ia IIC T6...T1 Gb; IEC Zone 0 Groups IIC, IIB, IIA; IEC Zone 20 Groups IIIC, IIIB, IIIA; IECEx Ex Ia I Mb; IECEx Ex Ia IIC T6...T1 Ga; IECEx Ex Ia IIC T6...T1 Gb; IECEx Ex Ia IIIC T135° C Da; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2C-UL Listed, CE Marked, UL Listed
    6305N112000000
     
    Accessories for Sensors

    Hazardous Location Differential Pressure Switches for Air

    Image of Product. Front orientation. Differential Pressure Switches.
    With an explosion-proof enclosure that meets NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL for use where explosive gas or dust may be present. Often used with ovens, dryers, and HVAC systems, they can indicate a filter is clogged or help maintain a certain air pressure. These switches turn equipment on and off, activate automated controls, or signal alarms when the differential pressure reaches your setpoint. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off.
    In addition to being UL listed, these switches are CE marked and FM approved, so they also meet European safety standards. They also are IP and NEMA rated for use outdoors and protect against dust and splashing water.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    Pressure Set Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Enclosure Rating
    Hazardous Location Rating
    Each
    Screw-Terminal Wire Connection
     
    1/8 NPT Female Pipe Connection
    0.07 in. H₂O to 0.15 in. H₂O0.13 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N110000000
    0.15 in. H₂O to 0.5 in. H₂O0.05 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N12000000
    0.4 in. H₂O to 1.6 in. H₂O0.18 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N13000000
    1.4 in. H₂O to 5.5 in. H₂O0.35 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N14000000
    3 in. H₂O to 11 in. H₂O0.45 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N15000000
    4 in. H₂O to 20 in. H₂O0.5 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N16000000
    0.5 psi to 2 psi0.3 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N17000000
    1.5 psi to 8 psi1 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N18000000
    3 psi to 15 psi0.9 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N19000000
    4 psi to 25 psi0.7 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N21000000
    15 psi to 50 psi1.25 psi70 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N22000000
     

    Fixed-Set-Point Hazardous-Location Flow Switches

    Image of Product. Front orientation. Flow Switches. Fixed-Set-Point Hazardous-Location Flow Switches.
    Safe to use where flammable gases and combustible dust may be present, these switches activate or deactivate when your flow reaches a factory-set level. All are UL listed for hazardous environments. Because their set point is fixed, they’re ready to go, making them easy to install. They actuate when your flowing liquid or gas pushes their paddle into a set position. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function accurately.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    Set Point
    Conduit
    Pipe
    Connections
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with Threaded 304 Stainless Steel Fittings
    1/2 NPT Female1.56.52,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/4"NEMA 4
    UL Listed
    CE Marked
    47565K610000000
    3/4 NPT Female2102,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 5/8"NEMA 4
    UL Listed
    CE Marked
    47565K62000000
    1 NPT Female3142,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3"NEMA 4
    UL Listed
    CE Marked
    47565K63000000
    2 NPT Female10432,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male4 3/4"NEMA 4
    UL Listed
    CE Marked
    47565K6600000000
     
    Brass Body with Threaded Brass Fittings
    1/2 NPT Female1.56.5250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/4"NEMA 4
    UL Listed
    CE Marked
    47565K31000000
    3/4 NPT Female210250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 3/8"NEMA 4
    UL Listed
    CE Marked
    47565K32000000
    1 NPT Female314250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/2"NEMA 4
    UL Listed
    CE Marked
    47565K33000000
    1 1/4 NPT Female421250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 5/8"NEMA 4
    UL Listed
    CE Marked
    47565K34000000
    1 1/2 NPT Female633250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 7/8"NEMA 4
    UL Listed
    CE Marked
    47565K35000000
    2 NPT Female1043250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3"NEMA 4
    UL Listed
    CE Marked
    47565K36000000
     

    Hazardous Location Cable-Pull-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Hazardous Location Cable-Pull-Actuator Emergency Stop Switches.
    Safe to use near ignitable gases and dust, the housing on these switches seals in anything that could ignite flammable material. All are UL listed and CSA certified for use in hazardous locations. Yank the cable anywhere along your line to quickly cut power in emergencies. They have positive-force, snap-open contacts that open a circuit when actuated, even if a spring fails or the contacts stick. The contacts will remain open until you tension the cable and reset the switch. Use the tension indicator to visually confirm that they’re reset correctly.
    Mounting
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Fasteners
    Included
    Hole Dia. (No.
    of Holes)
    Hole Thread Size
    (No. of Holes)
    Features
    Each
    Screw-Terminal Wire Connection
     
    1 Direction (NEMA 4; NEMA 7; NEMA 9; NEMA 13; NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G)
    20011 Off or 1 On
    3SPDT
    10 amp @ 600V AC
    10 amp @ 250V DC
    600V AC
    250V DC
    251/2
    No1/4" (2)5/16"-18 (2)Tension Indicator7543N11000000000
    20022 On
    4DPST-NC
    10 amp @ 600V AC
    10 amp @ 250V DC
    600V AC
    250V DC
    251/2
    No1/4" (2)5/16"-18 (2)Tension Indicator7543N1200000000
     

    Hazardous Location Float Switches for Chemicals

    Image of Product. Style A. Front orientation. Float Switches. Hazardous Location Float Switches for Chemicals, 316 Stainless Steel Body and Float, Style A.
    Image of Product. Style B. Front orientation. Float Switches. Hazardous Location Float Switches for Chemicals, 316 Stainless Steel Body and Float, Style B.

    Style A

    Style B

    Image of Attribute. Front orientation. Contains Annotated. Hazardous Location Float Switches for Chemicals.
    Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall.
    Style A—Style A meet Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
    Style B—Style B meet Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    316 Stainless Steel Body and Float
    A1/2
    NPT
    Male0.7300 psi @ 70° F0 to 3904 5/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/4
    NPT
    MaleUL Recognized Component, CSA Certified, CE Marked
    46815K110000000
    A1/2
    NPT
    Male0.7300 psi @ 70° F0 to 3904 5/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    MaleUL Recognized Component, CSA Certified, CE Marked
    46815K22000000
    A1
    NPT
    Male0.7300 psi @ 70° F0 to 3904 5/8"1 Off/1 On
    SPST-NO
    SPST-NC
    0.28 amp @ 120V ACWire Leads1/2
    NPT
    MaleUL Recognized Component, CSA Certified, CE Marked
    46815K21000000
    B1 1/2
    NPT
    Male0.41,500 psi @ 70° F0 to 3003 1/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACWire Leads1/2
    NPT
    MaleCSA Certified, FM Approved
    5300K55000000
    B2
    NPT
    Male0.41,500 psi @ 70° F0 to 3003 1/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACWire Leads1/2
    NPT
    MaleCSA Certified, FM Approved
    5300K58000000
     

    Hazardous-Location Flow Switches

    Image of Product. Front orientation. Flow Switches. Hazardous-Location Flow Switches.
    UL listed for use where flammable gases or combustible dusts may be present, these flow switches activate or deactivate equipment when your flow rate reaches a set point. Use the adjustment screw to select their set point. They actuate when your flowing liquid or gas pushes their paddle into a certain position determined by the set point. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). Mount them horizontally. Rated NEMA 4, they also protect against weather and washdowns.
    These flow switches are calibrated with water and air. You can use them with other liquids and gases, but they may not measure accurately if the viscosity is different from water or air.
    Flow Set Point
    Conduit
    Pipe
    Connections
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with Threaded 304 Stainless Steel Fittings
    1/2 NPT Female0.04 to 0.750.18 to 2.71,450 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3 5/8"NEMA 4
    UL Listed
    CE Marked
    91445K240000000
     
    Brass Body with Threaded Brass Fittings
    1/2 NPT Female0.04 to 0.750.18 to 2.71,450 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3 5/8"NEMA 4
    UL Listed
    CE Marked
    91445K23000000
     

    Hazardous Location Differential Pressure Switches for Liquids

    Image of Product. Front orientation. Differential Pressure Switches. Hazardous Location Differential Pressure Switches for Liquids.
    Tested and verified by UL and C-UL for use where explosive dust or gas are present, these switches have an explosion-proof enclosure that meets NEMA 7 and 9 standards for hazardous locations. They are often used to indicate a filter is clogged in a pump or cooling system. When the differential pressure reaches your setpoint, these switches can turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off.
    In addition to being UL and C-UL listed, these switches are CE marked, so they also meet European safety standards. All switches are IP and NEMA rated for use outdoors and to protect against some corrosion, dust, and washdowns.
    Pressure Set
    Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure Rating
    Hazardous Location Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4 NPT Female Pipe Connection
    5 in. H₂O to 80 in. H₂O2.5 in. H₂O225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N110000000
    2 psi to 20 psi0.2 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N12000000
    3 psi to 30 psi0.25 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N13000000
    10 psi to 100 psi0.6 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N14000000
     

    Paddle Level Switches for Dry Materials

    Image of Product. Front orientation. Contains Annotated. Paddle Level Switches. Horizontal Mount.
    Image of Product. Front orientation. Contains Annotated. Paddle Level Switches. Vertical Mount.

    Horizontal Mount

    Vertical Mount

    Monitor the level of dry material in surge bins, tanks, and silos to avoid overspills and outages. With a long paddle, these switches extend farther into large storage containers to detect material levels where other types of switches can’t reach. You can even adjust the paddle's sensitivity to materials of different sizes and shapes, such as powders, plastic pellets, and wood chips. Install multiple switches on the same container to monitor levels at various points. They are rated NEMA 4X and IP66 for protection from corrosion and washdowns.
    Horizontal Mount—Commonly installed near the bottom of containers to indicate low levels as material flows out. These switches start to rotate when material falls low enough to uncover the paddle, triggering a conveyor, pump, or other piece of equipment to prevent the container from emptying.
    Vertical Mount—Mount to the roof of containers to indicate high levels when loading material. For domed roofs, you can extend these switches farther down by connecting the paddle to your desired length of 1/8 NPT Schedule 40 pipe. The paddle rotates freely until material rises to its level and stops it, triggering a conveyor, pump, or other piece of equipment to prevent overfilling.
    With Alarm—Switches with an alarm alert you to potential malfunctions before they occur. They continuously perform self-diagnostics to detect everything from motor failure to seized bearings. When they detect an error, an LED light flashes in a corresponding code, so maintenance workers will immediately know which problem they need to fix.
    Paddle
    Switch
    Insertion
    Dp.
    Material Wt. Cap.
    Range, lb/ft³
    Max. Pressure
    @ Temp.
    Speed,
    rpm
    Lg.
    Wd.
    Material
    Starting
    Position
    Designation
    Current @
    Voltage
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Horizontal Mount
     
    Without Alarm
    6 5/8"3.4 to 3030 psi @ 70° F17"2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    20 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K510000000
     
    With Alarm
    6 5/8"3.4 to 3030 psi @ 70° F17"2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    8 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K26000000
     
    Vertical Mount
     
    Without Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    20 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K52000000
     
    With Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    8 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K36000000
     
    Replacements for Paddle Level Switches

    Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Style A. Front orientation. Style A. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.
    Image of Product. Style B. Front orientation. Style B. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.

    Style A

    Style B

    Image of Product. Style C. Front orientation. Style C. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.
    Image of Attribute. Front orientation. Contains Annotated. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.

    Style C

    Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall. All are rated NEMA 4 for protection from washdowns. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” or from “on” to “off”.
    Switches with a stainless steel body are more corrosion resistant than switches with a brass body.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Current @
    Voltage
    Float Material
    Trade
    Size
    Thread
    Type
    Gender
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body
    A1
    NPT
    Male0.7350 psi @ 70° F0 to 2201 3/4"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K120000000
    A1
    NPT
    Male0.91,000 psi @ 70° F0 to 2201 3/4"5 amp @ 120V ACPolypropylene
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K63000000
    B1
    NPT
    Male0.5200 psi @ 70° F0 to 2202 7/8"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K11000000
    C1 1/2
    NPT
    Male0.7100 psi @ 70° F0 to 27513 3/16"10 amp @ 120V AC316 Stainless Steel
    3/4
    NPT
    FemaleNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP56
    NEMA 4
    4914K86000000
     
    303 Stainless Steel Body
    A1
    NPT
    Male0.92,000 psi @ 70° F0 to 2201 3/4"5 amp @ 120V ACPolypropylene
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K65000000
    B1
    NPT
    Male0.5200 psi @ 70° F0 to 2202 7/8"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K13000000
     
    316 Stainless Steel Body
    C1 1/2
    NPT
    Male0.7100 psi @ 70° F0 to 27513 3/16"10 amp @ 120V AC316 Stainless Steel
    3/4
    NPT
    FemaleNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP56
    NEMA 4
    4914K8700000000
     

    Vertical-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Hazardous Location Float Switches for Fuels and Oils.
    For use in locations with flammable gases and combustible dust, these switches are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    316 Stainless Steel Body and Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K97000000000
     

    Hazardous-Location Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Hazardous-Location Insertion-Mount Flow Switches.
    Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. They are UL listed and CSA certified for use in hazardous locations. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline. They actuate when your system’s liquid pushes the paddle into a set position. To change your set point, the paddle has multiple layers that you can remove. For the lowest set point, use the largest paddle that will fit your pipe. To increase your set point, loosen the locking washers and remove paddles. You can trim the paddles to fine-tune your set point. The smaller the paddle, the higher the setpoint.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    SPDT—SPDT (singe pole, double throw) switches can turn one device from off to on (normally open) or from on to off (normally closed).
    DPDT—DPDT (double pole, double throw) switches can either turn two devices from off to on (normally open) or on to off (normally closed).
    Flow Set Point Range
    Max. Flow Rate
    Conduit
    Pipe
    Size
    Thread
    Type
    Gender
    For Pipe
    Size
    For Water and Oil
    For Air and Inert Gas
    For Water
    and Oil
    For Air and
    Inert Gas
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Body
    Ht.
    Each
    SPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K530000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5500000000
     
    DPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K54000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5600000000
     

    Remote-Sensing Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Remote-Sensing Hazardous Location Line-Voltage Thermostats.
    Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Sensor
    Cord Lg., ft.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 2772220 to 80SPDT
    Hardwire5 7/8"3"3 1/4"6NoNo3/8"AnalogNEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    CSA Certified, UL Listed
    1877K240000000
     

    Hazardous Location Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Hazardous Location Threaded Temperature Switches.
    Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,89710"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    5032K670000000
    0 to 225±2° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,78410"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    5032K8700000000
     

    Hazardous Location Wall-Mount Temperature Switches

    Image of Product. With Threaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.
    Image of Product. With Unthreaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—2 Circuits Controlled.

    With Threaded

    Probe

    With

    Unthreaded

    Probe

    Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range
    Temp.
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Includes
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Stainless Steel Probe—1/2 NPT Male
    30° F to 250° F±5° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    1/2 × 3/4 NPT Adapter Bushing5032K66000000000
     
    SPDT—2 Circuits Controlled
     
    Unthreaded Stainless Steel Probe
    30° F to 250° F±5° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    5032K8600000000
     
    Switch Mounts

    Hazardous Location Float Switches for Water

    Image of Product. Front orientation. Contains Annotated. Float Switches. Hazardous Location Float Switches for Water.
    For use in locations with flammable gases and combustible dust, these switch are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body and 316 Stainless Steel Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2755 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N130000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2757 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N16000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K96000000
    2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N11000000
     

    Hazardous Location Electrically Operated Air Directional Control Valves

    These valves are rated for environments where hazardous material is present. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Apply voltage to the electrical connection to actuate. Return actuation is by spring, so they go back to their original position when voltage is removed. Also known as 4-way valves.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Single Solenoid. Front orientation. Single Solenoid. Hazardous Location Electrically Operated Air Directional Control Valves.
    Image of Product. Double Solenoid. Front orientation. Double Solenoid. Hazardous Location Electrically Operated Air Directional Control Valves.

    Single Solenoid

    Double Solenoid

    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Hazardous Location Rating—Hazardous location ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Hazardous Location Rating
    Enclosure Rating
    Voltage
    Wire
    Connection
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Each
    5/2 Flow Pattern
     
    Single Solenoid
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    24V DCWire Leads6"1"2 7/8"No2992N110000000
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    120V ACWire Leads6"1"2 7/8"No2992N12000000
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    24V DCWire Leads9 3/8"1"2 7/8"No2992N13000000
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    120V ACWire Leads9 3/8"1"2 7/8"No2992N14000000
     
    Accessories for Valves

    Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Hazardous Location Line-Voltage Thermostats.
    Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    24 to 2772250 to 90SPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado1877K230000000
    24 to 2772250 to 90DPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado1877K25000000
     