    94 Products

    Sanitary Pressure Switches

    Image of Product. Front orientation. Contains Annotated. Pressure Switches. Sanitary Pressure Switches.
    3-A certified, these food-safe switches trigger automated controls and alarms when food-processing, pharmaceutical, and biotech lines reach a set pressure. These switches have many features that make them safe for sanitary environments because they reduce the space where bacteria could grow. A sleeve shields internal parts from water and other contaminants. Polished surfaces and smoothly welded seams make cleaning easier. Made of 316 stainless steel, they stand up to harsh cleaners and sanitizers without rusting. Rated IP67 and NEMA 6, they’re dust tight and withstand washdowns and temporary submersion.
    Connect them to your line with the same quick-clamp fittings (also known as tri-clamp fittings) that are common on sanitary lines since they’re easy to take apart for cleaning. The quick-clamp end has a diaphragm that protects the switches from corrosive material and covers threads to keep them clean. The diaphragm is filled with 99.5% pure USP food-grade glycerin, which keeps the switch clean if the diaphragm fails. It’s also laser etched with the serial number to reduce crevices.
    Twist the adjustable setpoint ring to make quick changes. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    All have a material certificate with traceable lot number and a calibration certificate traceable to NIST.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    Wd.
    For Use With
    Enclosure
    Rating
    Food Industry Std.
    Certification
    Each
    Wire Lead Connection
     
    For 1 1/2" OD Quick Clamp Tube
    6 to 303301,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N2020000000
    8 to 605601,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N203000000
    10 to 10041001,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N204000000
    20 to 200162001,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N205000000
     
    For 2" OD Quick Clamp Tube
    6 to 303301,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N207000000
    8 to 606601,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N208000000
    10 to 10041001,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N209000000
    20 to 200162001,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N211000000
     

    Magnetically Actuated Switches

    Image of Product. Style A. Front orientation. Style A. Magnetically Actuated Switches.
    Image of Product. Style B. Front orientation. Style B. Magnetically Actuated Switches.

    Style A

    Style B

    Image of Product. Style H. Front orientation. Style H. Magnetically Actuated Switches.
    Image of Specification. 6-Pole M12 Plug. Front orientation. 6 Poles. Magnetically Actuated Switches.

    Style H

    6-Pole

    M12

    Plug

    These switches actuate when a magnet comes within sensing distance, and reset when the magnet moves away. They’re often used to detect when a door or window opens. Mount the switch in a stationary position, such as a door frame, and mount the magnet to a movable object, such as the door. They do not include a safety relay and cannot be used with safety-guard doors found on machinery.
    M12 Connection—Switches with a M12 or M8 plug connect to cords with a socket (sold separately), allowing you to quickly connect and disconnect the switch.
    NEMA 6 Enclosure Rating—NEMA 6 rated switches are protected from temporary submersion.
    IP67 Enclosure Rating—IP67 rated switches protect against temporary submersion, as well as dust and dirt.
    Switches
    Replacement
    Magnets
    Wire
    Leads
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Designation
    Switching Current
    @ Voltage
    Max.
    Voltage
    Max. Sensing
    Distance
    No.
    of
    Lg.,
    ft.
    Lg.
    Wd.
    Ht.
    Enclosure
    Rating
    Each
    Each
    Plastic Housing with Wire Leads
    A11 On
    SPST-NC
    2 amp @ 230V AC230V AC0.47"263"1.19"0.63"NEMA 6, IP67
    65985K426000000065985K4410000000
    B11 On
    SPST-NC
    1 amp @ 30V DC30V DC0.47"2103.25"0.75"0.67"NEMA 6, IP67
    65985K42700000065985K439000000
    B11 On
    SPST-NC
    2 amp @ 230V AC230V AC0.47"2193.25"0.75"0.67"NEMA 6, IP67
    65985K42100000065985K439000000
    B21 Off and 1 On
    DPST-1NO/1NC
    1 amp @ 30V DC30V DC0.47"4193.25"0.75"0.67"NEMA 6, IP67
    65985K41900000065985K439000000
    B21 Off and 1 On
    DPST-1NO/1NC
    2 amp @ 230V AC230V AC0.47"4193.25"0.75"0.67"NEMA 6, IP67
    65985K43400000065985K439000000
    B22 On
    DPST-NC
    1 amp @ 30V DC30V DC0.47"4193.25"0.75"0.67"NEMA 6, IP67
    65985K42500000065985K439000000
    B22 On
    DPST-NC
    2 amp @ 230V AC230V AC0.47"4193.25"0.75"0.67"NEMA 6, IP67
    65985K42900000065985K439000000
    H31 Off and 2 On
    3PST-1NO/2NC
    0.3 amp @ 30V DC30V DC0.47"6162.08"1.1"0.55"NEMA 6, IP67
    65985K42300000065985K43800000
     
    Plastic Housing with 6-Pole M12 Plug
    H31 Off and 2 On
    3PST-1NO/2NC
    0.3 amp @ 30V DC30V DC0.47"2.08"1.1"0.55"NEMA 6, IP67
    65985K42400000065985K43800000
     
    Stainless Steel Housing with Wire Leads
    A31 Off and 2 On
    3PST-1NO/2NC
    1 amp @ 30V DC30V DC0.47"6103.11"1.3"0.63"NEMA 6, IP67
    65985K43200000065985K435000000
    B11 On
    SPST-NC
    2 amp @ 230V AC230V AC0.47"2103.21"0.75"0.75"NEMA 6, IP67
    65985K41800000065985K437000000
    B21 Off and 1 On
    DPST-1NO/1NC
    1 amp @ 30V DC30V DC0.47"4103.21"0.75"0.75"NEMA 6, IP67
    65985K43100000065985K437000000
    B31 Off and 2 On
    3PST-1NO/2NC
    1 amp @ 30V DC30V DC0.47"6103.21"0.75"0.75"NEMA 6, IP67
    65985K42800000065985K437000000
    H31 Off and 2 On
    3PST-1NO/2NC
    0.3 amp @ 30V DC30V DC0.47"6162.08"1.14"0.53"NEMA 6, IP67
    65985K43300000065985K436000000
     
    Stainless Steel Housing with 6-Pole M12 Plug
    H31 Off and 2 On
    3PST-1NO/2NC
    0.3 amp @ 30V DC30V DC0.47"2.08"1.14"0.53"NEMA 6, IP67
    65985K41700000065985K436000000
     
    Cords for Switches with Plug Connection

    Harsh Environment Potentiometers

    Image of Product. Front orientation. Potentiometers. Harsh Environment Potentiometers, Metal Housing.

    Metal

    Housing

    Rated NEMA 13, these potentiometers protect against debris and splashing oil and coolant. Also known as variable output switches, they vary electrical flow to control speed, volume, and light intensity.
    NEMA 6 Enclosure Rating—NEMA 6 potentiometers seal out water from temporary submersion as well as weather and washdowns.
    Actuator
    Wattage @ Voltage
    Max. Voltage
    For Panel Cutout
    Dia.
    Dp. Behind
    Panel
    No. of
    Turns
    Resolution
    Dia.
    Material
    Wire
    Connection
    Enclosure Rating
    Certification
    Choose a Maximum
    Resistance, kohm
    Each
    Metal Housing
    2 W @ 300V AC
    2 W @ 300V DC
    300V AC/300V DC1 3/16", 30 mm1 15/16"15%1 1/8"PlasticScrew Terminal
    NEMA 6, NEMA 13, IP65
    UL Listed, C-UL Listed, CSA Certified, CE Marked
    2.5, 5, 106787K520000000
     

    30 mm Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. 30 mm Panel-Mount Key Switches.
    These switches require a key to turn circuits on or off, limiting access to sensitive equipment. Rated NEMA 6, 13, and IP66, they're protected from washdowns and oil/coolant spraying. All are keyed alike, so they open with the same key. They include enough contact blocks to control the number of circuits listed.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Enclosure Rating
    Each
    2 Positions with Metal Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    11 Off
    Maintained
    2SPST-NO
    6 amp @ 120V AC, 2.5 amp @ 24V DC600V AC
    600V DC
    1 5/16"1 5/8"42LeftNEMA 6, NEMA 13, IP66
    9235K510000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    6 amp @ 120V AC, 2.5 amp @ 24V DC600V AC
    600V DC
    1 5/16"1 5/8"42LeftNEMA 6, NEMA 13, IP66
    9235K52000000
     
    Accessories and Replacements for Key Switches

    Joystick Switches

    Intuitively steer and position cranes, robot arms, and other machinery that moves in multiple directions—your equipment will follow the movements you make with these joysticks. They control multiple circuits as you move them in different directions and patterns. Assemble a complete switch with an actuator and at least one contact block (sold separately).
    Actuators
    Image of Product. Front orientation. Joystick Switches.
    All actuators include a mounting clip that can fit up to two contact blocks. They’re NEMA and IP rated for protection from dust, washdowns, and oil/coolant spraying.
    2 Positions—Two-position actuators require one to four contact blocks.
    4 Positions—Four-position actuators require two to four contact blocks. They are off in the center position.
    Momentary Switch—Momentary actuators can only be locked in the off position.
    Maintained Switch—Maintained actuators can be locked in any position.
    Chrome-Plated Steel—Chrome-plated steel actuators resist wear better than rubber actuators.
    Direction of
    Operation
    Switch
    Action
    Actuator Material
    Dp. Behind
    Panel
    Enclosure Rating
    Mfr.
    Each
    2 Positions for 30 mm (1 3/16") Diameter Panel Cutouts
    Down, UpMomentary
    Chrome-Plated Steel1 7/16"IP66, NEMA 6, NEMA 13
    Schneider Electric71025K1120000000
    Down, UpMaintained
    Chrome-Plated Steel1 7/16"IP66, NEMA 6, NEMA 13
    Schneider Electric71025K113000000
     
    4 Positions for 30 mm (1 3/16") Diameter Panel Cutouts
    Down, Left, Right, UpMomentary
    Chrome-Plated Steel1 7/16"IP66, NEMA 6, NEMA 13
    Schneider Electric71025K114000000
     
    Blocks
    Image of Product. Front orientation. Switch Contact Blocks.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Wire
    Connection
    Each
    For Schneider Electric Switches
    11 Off
    2SPST-NO
    Screw Terminal
    71025K1150000000
    11 On
    2SPST-NC
    Screw Terminal
    71025K116000000
     

    Water-Resistant Miniature Switch Mats

    Rated IP67 and NEMA 6, these switch mats withstand washdowns and temporary submersion. They have a smaller footprint than other switch mats to fit in confined spaces.
    With Wire Leads
    Image of Product. Front orientation. Switch Mats. Water-Resistant Miniature Switch Mats.
    Wire
    Leads
    Wd.
    Lg.
    Thk.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current
    @ Voltage
    Actuation
    Force, lbf
    Max. Pressure,
    psi
    No.
    of
    Lg.,
    ft.
    AWG
    Material
    Certification
    Each
    Black
    6"8"3/8"11 Off
    Momentary
    SPST-NO
    1 amp @ 24V AC/24V DC10 to 153,00021518
    Vinyl PlasticC-UL Recognized Component, UL Recognized Component
    7374K420000000
     

    Frame-Mounted Safety Switches

    Image of ProductInUse. Key Shown Actuating from the Side. Front orientation. Safety Switches. Frame-Mounted Safety Switches.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style B.

    Key Shown Actuating from the Side

    Style

    B

    Also known as interlock switches, these ensure the safety of personnel by automatically shutting off power to machinery when an access door opens. Mount the switch to the door frame and mount a key to the door so that the key is inserted into the switch when the door is closed. When the door opens, the key is removed from the switch and the machine shuts down. They’re often used with machine guards for large robots.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Style B—Style A-G switches have positive-force, normally closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick.
    IP67 Enclosure Rating—IP67 rated switches protect against temporary submersion.
    NEMA 6 Enclosure Rating—NEMA 6 rated switches protect against both temporary submersion and washdowns.
    Key Included—All switches require an actuator key, but not all include one—check whether you need to pick out a separate actuator key. For some switch styles, you can also select the mounting orientation of the key.
    Housing
    Conduit
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Ht.
    Wd.
    Dp.
    Trade
    Size
    Thread
    Type
    Key
    Included
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts
    B21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    5 amp @ 120V AC, 2 amp @ 24V DC500V AC
    250V DC
    3"1"1.1"1/2
    NPT
    YesIP67, NEMA 6
    65665K320000000
     

    Compact Pressure Switches

    With a round body that’s at least one-third thinner than traditional pressure switches, these fit in tight, cramped spaces. They’re often built into pumps and hydraulic systems with limited space in order to turn equipment on and off, activate automated controls, or signal alarms when they reach a set pressure. These switches are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They also meet at least one American, Canadian, or European safety standard.
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Compact Pressure Switches, Wire Lead Connection.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    IP67 Enclosure Rating and NEMA 6 Enclosure Rating—IP67 and NEMA 6 rated switches seal out dust and water from washdowns and temporary submersion.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    Internal Adjustment
    500 to 5,00041510,00015,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked, CSA Certified, UL Listed
    6303N1110000000
     
    7/16"-20 Threaded UN/UNF (SAE Straight) Male Pipe
     
    Internal Adjustment
    100 to 1,000905,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked, CSA Certified, UL Listed
    6303N125000000
    200 to 2,0001655,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked, CSA Certified, UL Listed
    6303N126000000
     
    DIN C Connection
    Image of Product. Front orientation. Pressure Switches. Compact Pressure Switches, DIN C Connection.
    External Adjustment—Switches with an external setpoint adjustment have an external ring, so you can set the pressure quickly by hand.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    IP67 Enclosure Rating and NEMA 6 Enclosure Rating—IP67 and NEMA 6 rated switches seal out dust and water from washdowns and temporary submersion.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    6 to 3038001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N1310000000
    8 to 6068001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N132000000
    10 to 10098001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N133000000
    20 to 200168001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N134000000
    50 to 500605,0008,000±2%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N135000000
    100 to 1,000855,0008,000±2%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N136000000
    200 to 2,0001655,0008,000±2%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N137000000
     
    Internal Adjustment
    500 to 5,00041510,00015,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N115000000
    750 to 7,50060510,00015,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N116000000
    1,500 to 15,0001,65015,00020,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N118000000
     
    7/16"-20 Threaded UN/UNF (SAE Straight) Male Pipe
     
    Internal Adjustment
    100 to 1,000905,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N119000000
    200 to 2,0001655,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N12000000
     

    Magnetic Contact Alarm Switches

    Image of Specification. Style A with Screw Terminals. Front orientation. Style A. Magnetic Contact Alarm Switches.
    Image of Specification. Style A with Wire Leads. Front orientation. Style A. Magnetic Contact Alarm Switches.
    Image of Specification. Style B. Front orientation. Style B. Magnetic Contact Alarm Switches.
    Image of Specification. Style D. Front orientation. Style D. Magnetic Contact Alarm Switches.

    Style A with Screw

    Terminals

    Style A with

    Wire Leads

    Style B

    Style D

    Wire contacts to an alarm system to alert when doors or windows are opened. Mount the magnet to the door or window and mount the switch to the frame. The alarm will activate when the magnet is pulled away by the opening door or window.
    SPDT—SPDT switches connect to an alarm system and to another device, such as a motion detector.
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Sensing
    Distance
    Wire Lead
    Lg., ft.
    Lg.
    Wd.
    Ht.
    Color
    Environment
    Enclosure Rating
    Each
    Plastic Housing with Wire Leads
     
    Adhesive Back with Sealed Housing
    A11 Off
    SPST-NO
    0.5 amp @ 100V AC/100V DC0.62"11.5"0.25"0.37"WhiteCorrosive, Dusty, Oily, Outdoor, Submersible, Washdown, WetNEMA 4X, NEMA 6, NEMA 12, IP67
    8039A2100000
     
    Aluminum Housing with Wire Leads
     
    Screw On with Flexible Stainless Steel Conduit and Sealed Housing
    A11 Off
    SPST-NO
    0.5 amp @ 100V AC/100V DC3"33"0.5"1"Corrosive, Dusty, Oily, Outdoor, Submersible, Washdown, WetNEMA 4X, NEMA 6, NEMA 12, IP67
    8039A5100000
    A11 Off or 1 On
    SPDT
    0.25 amp @ 30V AC/30V DC3"33"0.5"1"Corrosive, Dusty, Oily, Outdoor, Submersible, Washdown, WetNEMA 4X, NEMA 6, NEMA 12, IP67
    8039A52000000
    B11 Off
    SPST-NO
    0.5 amp @ 100V AC/100V DC3"33.5"1.5"1.5"Corrosive, Dusty, Oily, Outdoor, Submersible, Washdown, WetNEMA 4X, NEMA 6, NEMA 12, IP67
    8135A1100000
    B11 Off or 1 On
    SPDT
    0.25 amp @ 30V AC/30V DC3"33.5"1.5"1.5"Corrosive, Dusty, Oily, Outdoor, Submersible, Washdown, WetNEMA 4X, NEMA 6, NEMA 12, IP67
    8135A3200000
    D11 Off
    SPST-NO
    0.5 amp @ 100V AC/100V DC3"23.62"0.68"3"Corrosive, Dusty, Oily, Outdoor, Submersible, Washdown, WetNEMA 4X, NEMA 6, NEMA 12, IP67
    80425A3100000
     

    Access-Delay Frame-Mounted Safety Switches

    Image of ProductInUse. Key Shown Actuating from the Side. Front orientation. Safety Switches. Access-Delay Frame-Mounted Safety Switches.
    Image of Product. Front orientation. Safety Switches. Access-Delay Frame-Mounted Safety Switches, Style A.

    Key Shown Actuating from the Side

    Style A

    Delay access to hazardous areas until conditions are safe; use these switches with machines that take time to stop after they are turned off. Mount the switch to the door frame and mount the key to the door so that the key is inserted into the switch when the door is closed. When the door is pulled, the key is held in place with 225 lbs. of force until the switch receives a signal from a time-delay relay, motion sensor, or position sensor (not included) that the machine’s motion has stopped. After the motion has stopped, the key can be removed from the switch, releasing the access door. They’re often used with machine guards. All have positive-force, normally-closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick. They’re rated for protection from washdowns and temporary submersion.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Style A—Style A and B have a key entry on the top and side of the switch.
    Housing
    Conduit
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Input Voltage
    Holding
    Force, lbf
    Ht.
    Wd.
    Dp.
    Trade
    Size
    Thread
    Type
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts
    A31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    5 amp @ 120V AC, 2 amp @ 24V DC500V AC
    250V DC
    24V AC, 24V DC2254.7"2.3"1.4"1/2
    NPT
    IP67, NEMA 6
    7787K610000000
    A31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    5 amp @ 120V AC, 2 amp @ 24V DC500V AC
    250V DC
    110V AC2254.7"2.3"1.4"1/2
    NPT
    IP67, NEMA 6
    7787K62000000
     
    Keys

    Level Sensor Switches for Conductive Liquids

    Image of Product. Front orientation. Contains Annotated. Level Sensor Switches. Level Sensor Switches for Conductive Liquids.
    Designed to use the properties of conductive liquid for operation, these switches actuate when conductive liquid reaches the probes on the tip to close the circuit. They can be used with dirty fluid and liquid with high solid content, but are not for use with flammable liquids. Mount them horizontally or vertically. All are rated NEMA 6 for protection from washdowns.
    Pipe
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Probe Material
    Electrical
    Connection
    Wire Lead
    Lg., ft.
    Enclosure
    Rating
    Each
     
    PPS Body
    3/4
    NPT
    Male1290 psi @ 70° F-10 to 1751 1/2"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads
    6IP68, NEMA 6
    3915K110000000
    3/4
    NPT
    Male1290 psi @ 70° F-10 to 1753"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads
    6IP68, NEMA 6
    3915K12000000
     
    Polypropylene Body
    3/4
    NPT
    Male185 psi @ 70° F-10 to 1401 1/2"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads
    6IP68, NEMA 6
    3915K13000000
    3/4
    NPT
    Male185 psi @ 70° F-10 to 1403"1 Off or 1 On
    SPDT
    1 amp @ 24V DC316 Stainless SteelWire Leads
    6IP68, NEMA 6
    3915K14000000
     

    Photoelectric Sensors with Relay Output

    A built-in relay produces AC voltage output. These sensors are often used with older programmable logic controllers (PLCs). They detect the presence or absence of an object moving at high speeds with a light beam.
    With Wire Leads
    Image of Product. Front orientation. Photoelectric Sensors. Photoelectric Sensors with Relay Output , With Wire Leads.
    Direct Sensing—Direct sensing sensors detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
    IP67 Enclosure Rating and NEMA 6 Enclosure Rating—NEMA 6 and IP67 rated sensors withstand washdowns and temporary submersion.
    Light Beam Switch Operation
    Max. Sensing
    Distance
    Switch
    Designation
    Switching Current
    @ Voltage
    Input Voltage
    Lg.
    Ht.
    Wd.
    Cable Lead
    Lg., ft.
    Features
    Housing
    Material
    Mounting Thread
    Size
    Temp. Range,
    ° F
    Environment
    Certification
    Each
    Direct Sensing Sensor with Visible LED Light Beam (IP67, NEMA 6)
    On When Object Absent, On When Object Present7.9"SPDT
    5 amp @ 250V AC/30V DC24V AC to 250V AC/
    12V DC to 250V DC
    2 1/8"2 1/8"7/8"6 1/2RelayPlasticM30 × 1.5 mm0 to 155Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    2160N110000000
    On When Object Absent, On When Object Present15.7"SPDT
    5 amp @ 250V AC/30V DC24V AC to 250V AC/
    12V DC to 250V DC
    2 1/8"2 1/8"7/8"6 1/2RelayPlasticM30 × 1.5 mm0 to 155Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    2160N12000000
    On When Object Absent, On When Object Present23.6"SPDT
    5 amp @ 250V AC/30V DC24V AC to 250V AC/
    12V DC to 250V DC
    2 1/8"2 1/8"7/8"6 1/2RelayPlasticM30 × 1.5 mm0 to 155Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    2160N13000000
     

    Sanitary Pressure and Vacuum Switches

    Image of Product. Front orientation. Pressure Switches. Sanitary Pressure and Vacuum Switches.
    When these 3-A certified switches reach a set pressure or vacuum, they trigger controls and alarms in food-processing, pharmaceutical, and biotech lines. They have a sleeve to shield internal parts from water and contaminants. Their surfaces are polished and their seams are continuously welded, so cleaning is easy and there’s little room for bacteria to grow. Made of 316 stainless steel, these switches stand up to harsh cleaners and sanitizers without rusting. Rated IP67 and NEMA 6, they’re dust tight and protected from washdowns and temporary submersion.
    They connect using the same quick-clamp fittings (also known as tri-clamp fittings) that are common in sanitary lines, because they’re easy to take apart for cleaning. This end has a diaphragm that protects from corrosion and covers threads to keep them clean. The diaphragm is filled with 99.5% pure USP food-grade glycerin, reducing the risk of contamination if the diaphragm fails. The serial number is laser etched on the diaphragm to reduce crevices.
    Twist the adjustable setpoint ring to make quick changes. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    All have a material certificate with a traceable lot number and a calibration certificate traceable to NIST.
    Setpoint
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    Wire Lead Connection
     
    For 1 1/2" OD Quick Clamp Tube
    0 to 150 to 303151,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelArgon, Beverage, Diesel Fuel, Food, Gasoline, Hydraulic Fluid, Inert Gas, Natural Gas, Nitrogen, Oil, Oxygen, WaterIP67, NEMA 6
    UL Listed
    8834N2010000000
     
    For 2" OD Quick Clamp Tube
    0 to 150 to 303151,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelArgon, Beverage, Diesel Fuel, Food, Gasoline, Hydraulic Fluid, Inert Gas, Natural Gas, Nitrogen, Oil, Oxygen, WaterIP67, NEMA 6
    UL Listed
    8834N206000000
     

    Ultrasonic Switches

    Detect objects and liquid or material levels to set off actions in your system—regardless of size, shape, or surface finish. These switches send out high-frequency sound waves that target small areas, so the surface and structure of your object won't affect results like photoelectric sensors, which sense using light. This makes them great for materials with uneven surfaces, such as granules and powder. They also sense objects when obscured by smoke, dust, debris, or water, but they don't work as well where there's wind, since it could disrupt their sound waves. Once an object is detected or a set level is reached, the digital output sends a signal to your controller to turn components in your system on or off. Use their plug to quickly connect and disconnect to cables with a socket (sold separately). UL listed, C-UL listed, and CE marked, all meet American, Canadian, and European safety standards.
    Rated IP67, all of these switches seal out dust and water if briefly submersed.
    90° Elbow
    Image of Product. Front orientation. Ultrasonic Sensors. Ultrasonic Switches, 90° Elbow.
    Image of Specification. 4-Pole M12 Plug. Front orientation. 4 Poles.

    4-Pole

    M12

    Plug

    Switches with PNP/NPN signal output automatically produce the signal you need based on the connected device.
    90° elbow switches are compact to fit in tight spaces. They’re best for conveyors.
    NEMA 6 Enclosure Rating—NEMA 6 rated switches also stand up to weather and washdowns.
    Sensors
    Cables
    with Socket
    No. of
    Outputs
    Output Digital
    Signal
    Sensing
    Distance
    Input Voltage,
    V DC
    Dia.,
    mm
    Lg.,
    mm
    Wd.,
    mm
    Ht.,
    mm
    Circuit Protection
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Each
    Plastic Housing
     
    With 4-Pole M12 Plug-In Connection
    1PNP/NPN100 mm to 1 m10 to 3030454064Overload, Reverse Polarity, Short Circuit-40 to 155IP67, NEMA 6
    6565K6500000006897K36000000
    1PNP/NPN200 mm to 2 m10 to 3030454064Overload, Reverse Polarity, Short Circuit-40 to 155IP67, NEMA 6
    6565K660000006897K3600000
    1PNP/NPN300 mm to 3 m10 to 3030454064Overload, Reverse Polarity, Short Circuit-40 to 155IP67, NEMA 6
    6565K950000006897K3600000
     

    Precision Photoelectric Sensors

    Detect objects as thin as a freshly sharpened pencil tip. These sensors are best for tight spaces because they have a smaller light beam and can detect smaller objects than standard photoelectric sensors. They produce PNP or NPN signal output. To determine the signal output of a sensor you are replacing, use Testers for Proximity and Photoelectric Sensors (not included). All are rated IP67 for protection from dust and temporary submersion. Some also meet NEMA 6 for protection from washdowns.
    With Wire Leads
    Image of Product. Style A. Front orientation. Style A. Precision Photoelectric Sensors .
    Image of Product. Style B. Front orientation. Style B. Precision Photoelectric Sensors .

    Style

    A

    Style B

    Adjustable Light Beam—Adjustable sensors can increase the intensity of the light beam to better detect shiny or translucent objects.
    Direct Sensing—Direct sensing sensors detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
    Reflector Sensor—Reflector sensors detect an object when it passes between the sensor and the reflector, interrupting the beam. They have a shorter sensing distance than receiver sensors but are quicker to wire. They have a longer sensing distance than direct-sensing sensors.
    Style A—Style A direct sensing sensors have an adjustable maximum sensing distance, ranging from 6" down to 1.2". Set a shorter sensing distance to minimize false triggers caused by objects in the background.
    PNP Output Signal/NPN Output Signal—Sensors with PNP/NPN signal output automatically produce the type of signal output that is needed based on the device they are connected to.
    Style
    Light Beam Switch Operation
    Sensing
    Distance
    Input Voltage,
    V DC
    Current
    Output, mA
    Output Digital
    Signal
    Lg.
    Ht.
    Wd.
    Dia.,
    mm
    Mounting Thread
    Size
    Temp. Range,
    ° F
    Environment
    Enclosure
    Rating
    Certification
    Each
    Direct Sensing Sensor with Visible Light Beam
    AOn When Object Absent, On When Object Present0.04" to 6"10 to 30100PNP7/8"1 3/8"9/16"15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Recognized Component
    C-UL Recognized Component
    CE Marked
    5038T140000000
    AOn When Object Absent, On When Object Present0.04" to 6"10 to 30100NPN7/8"1 3/8"9/16"15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Recognized Component
    C-UL Recognized Component
    CE Marked
    5038T15000000
     
    Adjustable Direct Sensing Sensor with Visible Light Beam
    BOn When Object Absent, On When Object Present0" to 12"10 to 30100PNP1 1/4"1 3/8"5/8"18M18 × 1 mm15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Recognized Component
    C-UL Recognized Component
    CE Marked
    5038T12000000
    BOn When Object Absent, On When Object Present0" to 12"10 to 30100NPN1 5/16"1 3/8"9/16"18M18 × 1 mm15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Recognized Component
    C-UL Recognized Component
    CE Marked
    5038T13000000
    BOn When Object Absent, On When Object Present0" to 16"10 to 30150PNP/NPN1 1/4"1 3/4"7/8"30M30 × 1.5 mm15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Listed
    C-UL Listed
    CE Marked
    5038T19000000
    BOn When Object Absent, On When Object Present0" to 32"10 to 30150PNP/NPN1 1/4"1 3/4"7/8"30M30 × 1.5 mm15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Listed
    C-UL Listed
    CE Marked
    5038T21000000
     
    Adjustable Reflector Sensor with Visible Light Beam
    BOn When Object Absent, On When Object Present3.9" to 33 ft.10 to 30100PNP1 1/4"1 3/8"5/8"18M18 × 1 mm15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Recognized Component
    C-UL Recognized Component
    CE Marked
    5038T11000000
    BOn When Object Absent, On When Object Present4" to 33 ft.10 to 30100NPN1 5/16"1 3/8"9/16"18M18 × 1 mm15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Recognized Component
    C-UL Recognized Component
    CE Marked
    5038T16000000
    BOn When Object Absent, On When Object Present8" to 59 ft.10 to 30150PNP/NPN1 1/4"1 3/4"7/8"30M30 × 1.5 mm15 to 120Washdown
    Submersible
    Dusty
    Outdoor
    Wet
    IP67, NEMA 6
    UL Listed
    C-UL Listed
    CE Marked
    5038T17000000
     

    Ultrasonic Transmitters

    Measure the distance to objects and the level of liquids and materials despite size, shape, or surface finish, and send that information to other parts of your system. Unlike photoelectric switches, which use light to detect objects, these transmitters emit high-frequency sound waves that target small spots, so the surface and structure of your object won’t affect results. This makes them great for materials with uneven surfaces, such as granules and powder. They also sense objects in dirty and wet places, but they don’t work well where there’s wind, since it could disrupt their sound waves. Use their plug to quickly connect and disconnect to cables with a socket (sold separately). UL listed, C-UL listed, and CE marked, they meet American, Canadian, and European safety standards.
    All transmitters have an analog output, which means they continuously send measurements to monitor status and manage components in your system.
    Rated IP67, all of these transmitters seal out dust and water if briefly submersed.
    90° Elbow
    Image of Product. Front orientation. Ultrasonic Sensors. Ultrasonic Transmitters, 90° Elbow.
    Image of Specification. 4-Pole M12 Plug. Front orientation. 4 Poles.

    4-Pole

    M12

    Plug

    90° elbow transmitters are compact to fit in tight spaces. They’re best for conveyors.
    NEMA 6 Enclosure Rating—NEMA 6 rated transmitters also stand up to weather and washdowns.
    Sensors
    Cables
    with Socket
    No. of
    Outputs
    Output Analog
    Signal
    Sensing
    Distance
    Input Voltage,
    V DC
    Dia.,
    mm
    Lg.,
    mm
    Wd.,
    mm
    Ht.,
    mm
    Housing
    Material
    Circuit Protection
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Each
    With 4-Pole M12 Plug-In Connection
     
    Analog
    14 mA to 20 mA100 mm to 1 m10 to 3030454064PlasticOverload, Reverse Polarity, Short Circuit-40 to 155IP67, NEMA 6
    6565K3200000006897K36000000
    14 mA to 20 mA200 mm to 2 m10 to 3030454064PlasticOverload, Reverse Polarity, Short Circuit-40 to 155IP67, NEMA 6
    6565K440000006897K3600000
    10V DC to 10V DC100 mm to 1 m10 to 3030454064PlasticOverload, Reverse Polarity, Short Circuit-40 to 155IP67, NEMA 6
    6565K920000006897K3600000
    10V DC to 10V DC300 mm to 3 m10 to 3030454064PlasticOverload, Reverse Polarity, Short Circuit-40 to 155IP67, NEMA 6
    6565K940000006897K3600000
     
    back to top