Maximum Temperature Maximum Temperature |
---|
|
|
|
Scale Scale |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
For Maximum Chart Temperature For MaximumChart Temperature |
---|
|
|
Mounting Location Mounting Location |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Remote-Reading Panel-Mount Freezer Thermometers with Audible Alarm

Protect temperature-sensitive materials in refrigerators and freezers with one of these thermometers that sound an alarm and flash the display when temperature rises above your activation point. Alarm requires a power supply (sold separately).
Probe | Mtg. Holes | For Panel Cutout | Input Voltage | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Actuation Point Temperature Range | Resolution | Accuracy | Cable Lg., ft. | Dia. | Lg. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | AC | DC | Electrical Connection | Frequency, Hz | Each | |
-25° F to 99° F/-32° C to 38° C | -15° F to 50° F/-26° C to 10° C | 1/1 | ±3° F | 6 | 3/8" | 7/8" | 2 | 7/32" | No | 3 7/8" | 2 7/8" | 5" | 3 1/8" | 10.5 to 28 | 12 to 28 | Wire Leads | 60 | 000000 | 0000000 |
12V AC Output/120V AC Input Power Supply | 0000000 | Each | 000000 |
Remote-Reading Temperature Chart Recorders with High/Low Alarm
To alert you of temperature fluctuations, these recorders sound an alarm and flash the display when temperature rises above or falls below the programmable temperature range. They have a thermocouple type-K probe on a 4-ft. cable for taking readings in hard-to-access areas. Charts (not included) are required; select a recording time and temperature range from the available chart options.
Note: Thermocouple probes are not interchangeable with RTD probes.
Probe extension cable extends the probe's reach by 10 feet.
Chart Dia. | Temp. Range, °F | Temp. Range, °C | Recording Time | Pkg. Qty. | (Web) Table Pivot | Pkg. | |
Fahrenheit/Celsius | |||||||
---|---|---|---|---|---|---|---|
8" | -50° to 50° | -50° to 50° | 24 hrs. | 60 | __ | 000000000 | 000000 |
8" | -50° to 50° | -50° to 50° | 7 days | 60 | __ | 000000000 | 00000 |
8" | 0° to 100° | 0° to 100° | 24 hrs. | 60 | 1 | 000000000 | 00000 |
8" | 0° to 100° | 0° to 100° | 7 days | 60 | 2 | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 24 hrs. | 60 | __ | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 7 days | 60 | __ | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 24 hrs. | 60 | __ | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 7 days | 60 | __ | 000000000 | 00000 |
Charts for Temperature and Humidity Chart Recorders

Chart Dia. | Temp. Range, °F | Temp. Range, °C | Recording Time | Pkg. Qty. | Pkg. | |
8" | -50° to 50° | -50° to 50° | 24 hrs. | 60 | 000000000 | 000000 |
8" | -50° to 50° | -50° to 50° | 7 days | 60 | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 24 hrs. | 60 | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 7 days | 60 | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 24 hrs. | 60 | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 7 days | 60 | 000000000 | 00000 |
Remote Room-Monitoring Adjustable Thermostats
If ambient air temperature rises above or falls below an actuation point, this thermostat flashes the current temperature reading on the display and shows a “high” or “low” message. To actuate remote-mount buzzers (not included), it has two SPDT (single pole, double throw) relays that can each be set to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed). Switch has a built-in ambient temperature sensor.
12-volt DC power supply (not included) is required.
Remote-mount buzzers (not included) emit an 86 dB alarm when temperature reaches the actuation point.
Remote temperature sensors (not included) let you monitor temperature up to 1,000 feet from the switch. Remote sensors can be used simultaneously with the switch’s built-in ambient temperature sensor for monitoring two areas.