Maximum Flow Rate Maximum Flow Rate |
---|
Maximum Pressure Maximum Pressure |
---|
Vacuum Rating Vacuum Rating |
---|
Full Load Current Full Load Current |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Air Compressors
More
High-Flow Low-Pressure Compressed Air Blowers
Also known as regenerative blowers, use these to produce high-flow compressed air with low pressure or vacuum to operate pump drives, lift tables, and conveying systems. Compressed air blowers are also used for drying, exhausting, and aeration.
Air circulates inside the blower housing to compress air, which generates pressure or vacuum. Single-stage blowers circulate air once and then exhaust. Two-stage blowers circulate air twice and then exhaust, creating higher pressure or vacuum than single-stage blowers with the same horsepower.
Inverter-rated blowers have a motor that can run at slow speeds without overheating, so they can be used with a motor speed control (variable frequency drive).
For technical drawings and 3-D models, click on a part number.

Blowers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Pipe Size | Air-Intake Filters | Relief Valves | ||||||||||||||
Maximum Pressure | Max. Flow Rate @ psi | Vacuum Rating | hp | Full Load Current | Vol., dB | Lg. | Wd. | Ht. | Temp. Range, ° F | Inlet | Outlet | Each | Each | Each | |||
Single Phase, 120/208/230V AC | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
1 psi 29 in. of H2O | 27 cfm @ 0 | 1.9 in. of Hg 27 in. of H2O | 1/8 | 2.3 A @ 115 V AC 1.2 A @ 208 V AC 1.2 A @ 230 V AC | 57 | 9" | 8" | 9" | 32° to 100° | 1 | 1 | 0000000 | 0000000 | 00000000 | 0000000 | 00000000 | 0000000 |
1 psi 39 in. of H2O | 42 cfm @ 0 | 2.6 in. of Hg 35 in. of H2O | 1/3 | 3.8 A @ 115 V AC 2.0 A @ 208 V AC 1.9 A @ 230 V AC | 63 | 10" | 9" | 9" | 32° to 100° | 1 | 1 | 0000000 | 000000 | 00000000 | 000000 | 00000000 | 000000 |
2 psi 42 in. of H2O | 52 cfm @ 0 | 3.0 in of Hg 40 in. of H2O | 1/2 | 6.0 A @ 115 V AC 3.2 A @ 208 V AC 3.0 A @ 230 V AC | 68 | 13" | 10" | 10" | 32° to 100° | 1 1/4 | 1 1/4 | 0000000 | 000000 | 00000000 | 000000 | 00000000 | 000000 |
2 psi 52 in. of H2O | 92 cfm @ 0 | 3.5 in. of Hg 48 in. of H2O | 1 | 9.8 A @ 115 V AC 5.2 A @ 208 V AC 4.9 A @ 230 V AC | 68 | 13" | 11" | 12" | 32° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
2 psi 65 in. of H2O | 127 cfm @ 0 | 4.4 in. of Hg 60 in. of H2O | 1 1/2 | 17.5 A @ 115 V AC 10.0 A @ 208 V AC 9.0 A @ 230 V AC | 74 | 16" | 13" | 14" | 32° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
Single Phase, 120/230V AC | |||||||||||||||||
BSPP Female Inlet and Outlet | |||||||||||||||||
2 psi 56 in. of H2O | 57 cfm @ 0 | 3.8 in. of Hg 52 in. of H2O | 1/2 | 6.0 A @ 115 V AC 3.0 A @ 230 V AC | 56 | 10" | 10" | 10" | 5° to 100° | 1 1/4 | 1 1/4 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
3 psi 76 in. of H2O | 102 cfm @ 0 | 5.3 in. of Hg 72 in. of H2O | 1 1/2 | 14.0 A @ 115 V AC 7.0 A @ 230 V AC | 64 | 12" | 11" | 12" | 5° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
NPT Female Inlet and Outlet | |||||||||||||||||
3 psi 72 in. of H2O | 148 cfm @ 0 | 5.3 in. of Hg 72 in. of H2O | 2 1/4 | 24.0 A @ 115 V AC 12.0 A @ 230 V AC | 70 | 14" | 13" | 13" | 5° to 100° | 2 | 2 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
Three Phase, 190/230/380/460V AC (Inverter Rated) | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
2 psi 56 in. of H2O | 103 cfm @ 0 | 4.1 in. of Hg 56 in. of H2O | 1 | 4.4 A @ 190 V AC 3.7 A @ 230 V AC 2.2 A @ 380 V AC 2.1 A @ 460 V AC | 64 | 11" | 11" | 12" | 32° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
3 psi 79 in. of H2O | 150 cfm @ 0 | 6.5 in. of Hg 88 in. of H2O | 2 3/4 | 7.5 A @ 190 V AC 7.3 A @ 230 V AC 4.3 A @ 380 V AC 4.4 A @ 460 V AC | 70 | 14" | 13" | 15" | 32° to 100° | 2 | 2 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
3 psi 92 in. of H2O | 221 cfm @ 0 | 7.1 in. of Hg 96 in. of H2O | 4 1/2 | 12.5 A @ 190 V AC 12.6 A @ 230 V AC 7.2 A @ 380 V AC 7.3 A @ 460 V AC | 72 | 15" | 15" | 17" | 32° to 100° | 2 | 2 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
4 psi 116 in. of H2O | 150 cfm @ 0 | 7.7 in. of Hg 104 in. of H2O | 3 1/4 | 9.7 A @ 190 V AC 10.3 A @ 230 V AC 5.6 A @ 380 V AC 6.0 A @ 460 V AC | 70 | 14" | 13" | 15" | 32° to 100° | 2 | 2 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
Three Phase, 208/230/460V AC | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
2 psi 43 in. of H2O | 53 cfm @ 0 | 2.9 in. of Hg 40 in. of H2O | 1/2 | 2.0 A @ 208 V AC 2.0 A @ 230 V AC 1.0 A @ 460 V AC | 68 | 11" | 10" | 10" | 32° to 100° | 1 1/4 | 1 1/4 | 0000000 | 000000 | 00000000 | 000000 | 00000000 | 000000 |
2 psi 52 in. of H2O | 92 cfm @ 0 | 3.5 in. of Hg 48 in. of H2O | 1 | 3.4 A @ 208 V AC 3.2 A @ 230 V AC 1.6 A @ 460 V AC | 68 | 13" | 11" | 12" | 32° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
2 psi 65 in. of H2O | 127 cfm @ 0 | 4.4 in. of Hg 60 in. of H2O | 1 1/2 | 5.1 A @ 208 V AC 4.9 A @ 230 V AC 2.5 A @ 460 V AC | 74 | 14" | 13" | 14" | 32° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
Three Phase, 208/230/460V AC (Inverter Rated) | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
4 psi 105 in. of H2O | 207 cfm @ 0 | 6.5 in. of Hg 88 in. of H2O | 5 | 13.0 A @ 208 V AC 12.0 A @ 230 V AC 6.0 A @ 460 V AC | 72 | 19" | 15" | 15" | 32° to 100° | 2 | 2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
4 psi 110 in. of H2O | 265 cfm @ 0 | 6.6 in. of Hg 90 in. of H2O | 6 | 16.0 A @ 208 V AC 15.0 A @ 230 V AC 7.5 A @ 460 V AC | 79 | 17" | 17" | 18" | 32° to 100° | 2 | 2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
5 psi 125 in. of H2O | 420 cfm @ 0 | 8.1 in. of Hg 110 in. of H2O | 10 | 35.0 A @ 208 V AC 29.5 A @ 230 V AC 15.0 A @ 460 V AC | 78 | 22" | 18" | 20" | 32° to 100° | 2 1/2 | 2 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
Three Phase, 220/275/380/480V AC (Inverter Rated) | |||||||||||||||||
BSPP Female Inlet and Outlet | |||||||||||||||||
2 psi 64 in. of H2O | 57 cfm @ 0 | 4.4 in. of Hg 60 in. of H2O | 1/2 | 2.6 A @ 200 V AC 2.6 A @ 275 V AC 1.5 A @ 380 V AC 1.5 A @ 480 V AC | 56 | 10" | 10" | 10" | 5° to 100° | 1 1/4 | 1 1/4 | 0000000 | 00000000 | 000000 | 00 | 000000 | 00 |
Three Phase, 230/460V AC (Inverter Rated) | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
4 psi 105 in. of H2O | 795 cfm @ 0 | 7.0 in. of Hg 95 in. of H2O | 18 | 52.0 A @ 230 V AC 26.0 A @ 460 V AC | 79 | 29" | 18" | 20" | 32° to 100° | 2 1/2 | 4 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000000 |

Blowers | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Pipe Size | Relief Valves | |||||||||||||
Maximum Pressure | Max. Flow Rate @ psi | Vacuum Rating | hp | Full Load Current | Vol., dB | Lg. | Wd. | Ht. | Temp. Range, ° F | Inlet | Outlet | Each | Each | ||
Three Phase, 208/230/460V AC (Inverter Rated) | |||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||
5 psi 140 in. of H2O | 65 cfm @ 0 | 11.1 in. of Hg 151 in. of H2O | 2 | 5.8 A @ 208 V AC 5.2 A @ 230 V AC 2.8 A @ 460 V AC | 72 | 16" | 13" | 14" | 5° to 100° | 1 1/4 | 1 1/4 | 0000000 | 000000000 | 0000000 | 0000000 |
5 psi 141 in. of H2O | 81 cfm @ 0 | 11.1 in. of Hg 151 in. of H2O | 3 | 8.3 A @ 208 V AC 7.4 A @ 230 V AC 4.0 A @ 460 V AC | 73 | 16" | 14" | 15" | 5° to 100° | 1 1/4 | 1 1/4 | 0000000 | 00000000 | 0000000 | 000000 |
Plug-In Wet/Dry Vacuum/Blowers


Use the included blower nozzle to convert this vacuum cleaner to a hand-held blower.
Hose | Blower Nozzle | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Ht. | Wd. | Dp. | hp | Current, A | Voltage | Dia. | Lg., ft. | Dia. | Lg. | Cord Lg., ft. | Specifications Met | Features | Includes | Each | |
Plastic Tank | ||||||||||||||||
16 | 25 1/2" | 20 3/4" | 23" | 6.5 | 12 | 120V AC | 1 7/8" | 8 | 2 1/2" | 23" | 20 | UL Listed | Drain, Liquid Overflow Shut-Off Valve | Floor Nozzle Tool Holder Blower Nozzle Two 20" Lg. Extension Wands Utility Nozzle | 00000000 | 0000000 |


Component | Manufacturer Equivalent Number | For Vacuum Capacity | For Pickup Type | Filter Efficiency @ 0.3 Microns | Includes | Pkg. Qty. | Pkg. | |
Foam Filter | VF7000 | 6 gal. and up | Wet | __ | __ | 1 | 00000000 | 000000 |
Cartridge Filter | VF4000RT | 6 gal. and up | Wet/Dry | __ | __ | 1 | 00000000 | 00000 |
Cartridge Filter | VF6000 | 6 gal. and up | Wet/Dry | 99.97% | __ | 1 | 0000000 | 00000 |
Cartridge Filter | VF6500RT | 12-16 gal. | Wet/Dry | 99.97% | Two Cartridge Pre-Filters | 1 | 00000000 | 00000 |
Fine-Dust Cartridge Filter | VF5000RT | 6 gal. and up | Wet/Dry | __ | __ | 1 | 00000000 | 00000 |
Fine-Filtration Plug-In Hand-Held Vacuum/Blowers for Dry Pickup
Protect air quality with this vacuum/blower that has a HEPA filter. It is the most powerful hand-held option for dry pickup. Its two-speed motor provides low power for cleaning intricate areas and maximum power for heavy duty cleanups. It can pick up printing toner.

Hose | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., qt. | Voltage | Filter Efficiency @ 0.3 Microns | Dia. | Lg. | hp | Current, A | Dia. | Lg., ft. | Cord Lg., ft. | Specifications Met | Includes | Each | |
Steel | |||||||||||||
1 | 120V AC | 99.97% | 7" | 17 1/2" | 1.7 | 7.3 | 1 1/4" | 6 | 12 | UL Listed | Two 20" Lg. Extension Wands, Crevice Tool, Dust Brush, Utility Nozzle, Two Tapered Nozzles, Two Wands, Micro Tool Kit (Adapter, 6 3/8" Flexible Extension Wand, Dust Brush, Crevice Tool), Shoulder Strap, Cloth Bag | 00000000 | 0000000 |
Plug-In Hand-Held Vacuum/Blowers for Dry Pickup
Light Duty Plug-In Hand-Held Vacuum/Blowers for Dry Pickup

This vacuum/blower is for light cleaning and is able to get into narrow openings.
Hose | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., qt. | Ht. | Wd. | Dp. | hp | Current, A | Voltage | Dia. | Lg., ft. | Cord Lg., ft. | Specifications Met | Includes | Each | |
Steel | |||||||||||||
1/2 | 4" | 4" | 16" | 0.5 | 1.7 | 120V AC | 1 1/4" | 1 1/2 | 12 | UL Listed | Blower Nozzle, Round Brush, Crevice Tool, Micro Tool Kit (Adapter, 6 3/8" Flexible Extension Wand, Dust Brush, Crevice Tool), Shoulder Strap | 0000000 | 0000000 |
Replacement Collection Bags (5/Pkg.) | 0000000 | Pkg. | 000000 |
Air-Powered Hand-Held Vacuum/Blowers for Dry Pickup


Use as either a vacuum or a blower—change the airflow direction to switch functions. These vacuum/blowers clean up dirt, dust, metal chips, and glass around machinery and workstations.
Vacuuming requires the reusable collection bag with clamp or the discharge hose, both sold separately.
Vacuum/blower with blowout tube simultaneously dislodges and vacuums debris such as metal chips.
Backpack Vacuum/Blowers for Dry Pickup

More powerful than the standard backpack vacuum cleaner, this vacuum converts to a blower with the included blower nozzle. Carry this lightweight vacuum/blower on your back for comfortable mobility while cleaning.
Hose | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Dia. | Ht. | Current, A | Voltage | Dia. | Lg., ft. | Cord Lg., ft. | Includes | Each | |
Plastic Housing | ||||||||||
2 1/2 | 9" | 26 1/2" | 9.9 | 120V AC | 1 1/2" | 4 1/2 | 50 | 56" Lg. Extension Wand Blower Nozzle Crevice Tool Floor Nozzle Round Dust Brush | 00000000 | 0000000 |
Electric Blowguns for Large Areas

Clear dust and debris, test air ducts for leaks, and dry large surfaces without needing a compressed air line. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
Attach the optional vacuum kit (sold separately) to convert the blowgun to a handheld vacuum.
Number of Speeds | Airflow, cfm | Nozzle Lg. | Volume, dB | Tip OD | O'all Lg. | Body Material | Nozzle Tip Material | Voltage | Cord Lg., ft. | Specifications Met | Each | |
Straight | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 105 | 8" | 93 | 3/4" | 15 1/2" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 000000000 |
1 | 155 | 8" | 92 | 3/4" | 16 1/2" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 00000000 |
2 | 150, 195 | 8" | 93 | 3/4" | 18" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 00000000 |
2 | 150, 195 | 8" | 94 | 3/4" | 18" | Painted Aluminum | Aluminum | 240V AC | 21 | UL Listed | 0000000 | 00000000 |
Vacuum Kits | 0000000 | Each | 0000000 |
Hand-Held Blowers
Clear leaves and debris. These blowers come with a bag attachment and can also be used as a vacuum.
Battery operated blowers cannot be sold to Canada due to local energy efficiency requirements.

Max. Airflow, mph | O'all Lg. | Material | Plug Type | Includes | Specifications Met | Each | |
250 | 43" | Plastic | Two Prong | Vacuum Kit with Bag | CSA Certified | 000000 | 0000000 |