Material Material |
---|
|
Overall Width Overall Width |
---|
|
|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Connection Type Connection Type |
---|
![]() | ![]() |
Press Fit | Quick- Disconnect Clamp |
Overall Height Overall Height |
---|
|
|
|
Overall Depth Overall Depth |
---|
|
|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Duct Connections
More
About Calculating the Airflow Required for Air Cleaning
More
Suspended-Hood Fume Exhausters

Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All include a pulley system to adjust the hood height. Add an optional swivel wall bracket (sold separately) for side-to-side movement.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Exhausters | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Hose | Optional Swivel Wall Bracket | ||||||||||
Hood Dia. | Airflow @ Static Pressure | Volume | Power, hp | ID | Lg., ft. | Mounting Location | Includes | Each | Each | ||
120V AC—Plug | |||||||||||
27" | 500 cfm @ 0 in. of H 2 O | 50 dB @ 15 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 0000000 | 00000000 | 0000000 |
32" | 500 cfm @ 0 in. of H 2 O | 50 dB @ 15 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 000000 | 00000000 | 000000 |
37" | 500 cfm @ 0 in. of H 2 O | 50 dB @ 15 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 000000 | 00000000 | 000000 |
44" | 500 cfm @ 0 in. of H 2 O | 50 dB @ 15 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 00000000 | 00000000 | 000000 |
Floor-Mount Fume Exhausters


Remove fumes, vapors, and fine dust particles from your space. These exhausters are commonly used in welding, soldering, and other operations that create fumes.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Totally enclosed exhausters have an external fan for cooling. These exhausters offer more protection than open dripproof exhausters. They can be used in dirty, dusty, and damp environments, but are not airtight.
Single-duct kits (sold separately) maximize airflow at one fume collection point. They include a hose, a nozzle, and two clamps.
Dual-duct kits (sold separately) create two points for fume collection, although each will have lower airflow than the one collection point of a single-duct kit. These kits include two hoses, two nozzles, four clamps, and a wye connector.
Overall | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Power, hp | Inlet Dia. | Outlet Dia. | Ht. | Wd. | Dp. | Housing Material | Base Material | Fasteners Included | For Screw Size | Hole Dia. | Number of Holes | Each | |
Totally Enclosed | |||||||||||||||
120V AC,Single Phase—Plug | |||||||||||||||
755 cfm @ 1/2 in. of H₂O | 72 dB @ 15 ft. | 3/4 | 6" | 6" | 20 1/4" | 17" | 15 3/4" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 000000000 |
230V AC,Single Phase—Hardwire | |||||||||||||||
1,135 cfm @ 1/2 in. of H₂O | 78 dB @ 15 ft. | 3 | 6" | 6" | 22 7/8" | 19 1/8" | 18 1/4" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
120/230V AC,Single Phase—Hardwire | |||||||||||||||
1,045 cfm @ 1/2 in. of H₂O | 75 dB @ 15 ft. | 1 1/2 | 6" | 6" | 16 3/8" | 12 1/4" | 18" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,615 cfm @ 1/2 in. of H₂O | 72 dB @ 15 ft. | 2 | 8" | 8" | 21 1/2" | 14 7/8" | 18 5/8" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
230/460V AC,Three Phase—Hardwire | |||||||||||||||
450 cfm @ 1/2 in. of H₂O | 64 dB @ 15 ft. | 1/4 | 6" | 6" | 16 3/8" | 12 1/4" | 15 1/4" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 000000 |
855 cfm @ 1/2 in. of H₂O | 74 dB @ 15 ft. | 1 1/2 | 6" | 6" | 22 7/8" | 19 1/8" | 17 1/8" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,135 cfm @ 1/2 in. of H₂O | 78 dB @ 15 ft. | 3 | 6" | 6" | 22 7/8" | 19 1/8" | 19 7/8" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,615 cfm @ 1/2 in. of H₂O | 72 dB @ 15 ft. | 2 | 8" | 8" | 21 1/2" | 14 7/8" | 18 1/4" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
Suspended-Hood Hazardous Location Fume Exhausters

Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All have a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups F and G locations. Exhausters include a pulley system to adjust the hood height. Add an optional swivel wall bracket (sold separately) for side-to-side movement.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Exhausters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Hose | Optional Swivel Wall Bracket | |||||||||||
Hood Dia. | Airflow @ Static Pressure | Volume | Power, hp | ID | Lg., ft. | Mounting Location | Includes | Environmental Rating | Each | Each | ||
120/230V AC—Hardwire | ||||||||||||
27" | 450 cfm @ 0 in. of H 2 O | 59 dB @ 15 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 000000000 | 00000000 | 0000000 |
32" | 450 cfm @ 0 in. of H 2 O | 59 dB @ 15 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 00000000 | 00000000 | 000000 |
37" | 450 cfm @ 0 in. of H 2 O | 59 dB @ 15 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 00000000 | 00000000 | 000000 |
44" | 450 cfm @ 0 in. of H 2 O | 59 dB @ 15 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 00000000 | 00000000 | 000000 |
Swivel-Arm Fume Exhaust Hoses

For exact positioning, this hose swivels 360° to remove fumes, vapors, and fine dust particles from your space. It's commonly used in welding, soldering, and other operations that create fumes.
Hose | Nozzle | Mounting | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ID | Lg., ft. | Material | Dia. | Material | Fasteners Included | For Screw Size | Hole Dia. | Number of Holes | Includes | Each | |
Bench and Wall Mount | |||||||||||
3" | 5 | PVC Plastic | 5" | Powder-Coated Aluminum | No | 1/4"-20 | 3/8" | 6 | Hose, Mounting Bracket, Nozzle | 0000000 | 0000000 |
Adjustable-Length Fume Exhaust Hoses

The arm length adjusts from 3 to 6 feet making these exhaust hoses good for locations with low ceilings. Use these hoses to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
Hose | Nozzle | Mounting | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
ID | Lg., ft. | Material | Dia. | Material | Fasteners Included | Hole Dia. | Number of Holes | Includes | Each | |
Ceiling Mount | ||||||||||
6 1/4" | 3-6 | PVC-Coated Nylon Plastic | 11 3/4" | Powder-Coated Steel | No | 1/2" | 4 | Hose, Mounting Bracket, Nozzle | 0000000 | 000000000 |
Positionable-Arm Fume Exhaust Hoses

Move the hose into position and the support arm will hold it in place. These hoses remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
Hose | Nozzle | Mounting | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ID | Lg., ft. | Material | Dia. | Material | Fasteners Included | For Screw Size | Hole Dia. | Number of Holes | Includes | Each | |
Ceiling and Wall Mount | |||||||||||
4" | 5 | PVC Plastic | 10" | Steel | No | 3/8" | 1/2" | 4 | Hose, Mounting Bracket, Nozzle | 0000000 | 000000000 |
4" | 7 | PVC Plastic | 10" | Steel | No | 3/8" | 1/2" | 4 | Hose, Mounting Bracket, Nozzle | 0000000 | 00000000 |
4" | 8.5 | PVC Plastic | 10" | Steel | No | 3/8" | 1/2" | 4 | Hose, Mounting Bracket, Nozzle | 0000000 | 00000000 |
6" | 7 | PVC Plastic | 13" | Steel | No | 3/8" | 1/2" | 6 | Hose, Mounting Bracket, Nozzle | 0000000 | 00000000 |
6" | 10 | PVC Plastic | 13" | Steel | No | 3/8" | 1/2" | 6 | Hose, Mounting Bracket, Nozzle | 0000000 | 00000000 |
8" | 10 | PVC Plastic | 14" | Steel | No | 3/8" | 1/2" | 8 | Hose, Mounting Bracket, Nozzle | 0000000 | 00000000 |
Enclosure Intake and Exhaust Hoods

These hoods keep your enclosure watertight, even around intake and exhaust cutouts. The silicone seal shuts out water and dust, while the slanted top lets water roll off. When used over fans or vents rated IP54 or higher, hoods meet IP56 and NEMA 4X to help protect your electronics from wet and corrosive environments, dust, and washdowns. They also meet American, Canadian, and European safety standards.
Screw the mounting bracket around your fan or vent, then clip the hood on. Pop it off for cleaning, changing filters, and other maintenance.
Cutout | Overall | Mounting Holes | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Height | Width | Depth | Material | Environmental Rating | Mounting Fasteners Included | Number of | Diameter | Specifications Met | Each | |
5 1/2" | 5" | 8 3/8" | 7 5/8" | 1 7/8" | Stainless Steel | IP56, NEMA 4X | No | 4 | 0.15" | CE Marked, C-UL Recognized Component, UL Recognized Component | 0000000 | 0000000 |
6 3/4" | 6 1/4" | 11" | 8 7/8" | 2 1/4" | Stainless Steel | IP56, NEMA 4X | No | 4 | 0.15" | CE Marked, C-UL Recognized Component, UL Recognized Component | 0000000 | 000000 |
9 1/4" | 8 1/2" | 14 1/8" | 11 5/8" | 2 5/8" | Stainless Steel | IP56, NEMA 4X | No | 6 | 0.15" | CE Marked, C-UL Recognized Component, UL Recognized Component | 0000000 | 000000 |
11 3/8" | 11 1/4" | 16 3/8" | 14 1/2" | 3" | Stainless Steel | IP56, NEMA 4X | No | 6 | 0.15" | CE Marked, C-UL Recognized Component, UL Recognized Component | 0000000 | 000000 |
13 3/8" | 12 3/4" | 19 1/8" | 16 1/8" | 4" | Stainless Steel | IP56, NEMA 4X | No | 6 | 0.15" | CE Marked, C-UL Recognized Component, UL Recognized Component | 0000000 | 000000 |
Quick-Disconnect Duct and Fittings

Join duct and fittings with quick-release clamps for faster disassembly and cleanout than other duct systems.
Galvanized steel has good corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Chemical-Resistant Duct and Fittings

Made of PVC plastic to withstand acids, alkalies, salts, and other corrosive vapors and fumes. Use PVC pipe cement (not included) to secure components. Fittings have female ends with a slightly larger diameter to press-fit over duct.
For technical drawings and 3-D models, click on a part number.
Fume Hoods



Pair these hoods with an exhaust system to contain harmful fumes, vapors, and gasses while venting them away from work spaces—they protect users from inhaling or coming in contact with them. To access the enclosed space, these hoods have an adjustable sliding window, which also lets your exhaust system pull air from the outside. Polycarbonate windows are more durable than acrylic windows. All of these hoods resist chemicals and corrosion.
Polyethylene hoods have a molded one-piece construction with rounded inside corners to prevent gaps and crevices, making them easy to wipe clean.
Polypropylene hoods are nonconductive. They’re also translucent, so they let in more light than polyethylene hoods for added visibility.
Polycarbonate hoods are dent and scratch resistant. They’re also clear, offering an unobstructed view from all sides.
Overall | Opening | Windows | Outlets | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recommended Airflow, cfm | Height | Width | Depth | Height | Width | Number of | Material | Clarity | Number of | OD | Gender | Each | |
Polyethylene Plastic with Adjustable Sliding Window | |||||||||||||
200 | 22" | 27" | 13" | 12" | 22" | 1 | Acrylic Plastic | Clear | 1 | 4", 6" | Male | 00000000 | 0000000 |
350 | 30" | 42" | 20" | 14 1/8" | 34 1/2" | 1 | Acrylic Plastic | Clear | 1 | 6" | Male | 00000000 | 00000000 |
Polypropylene Plastic with Adjustable Sliding Window | |||||||||||||
500 | 36" | 48" | 24" | 21" | 46" | 1 | Acrylic Plastic | Clear | 1 | 6" | Male | 00000000 | 00000000 |
Polycarbonate Plastic with Adjustable Sliding Window | |||||||||||||
200 | 26 1/8" | 25 7/8" | 24" | 13" | 20 1/8" | 1 | Polycarbonate Plastic | Clear | 1 | 6" | Male | 00000000 | 00000000 |
200 | 26 1/8" | 43 7/8" | 24" | 13" | 38 1/8" | 1 | Polycarbonate Plastic | Clear | 2 | 6" | Male | 00000000 | 00000000 |
Bench Top Spray Booths

Use this portable spray booth for small projects. Contain overspray and discharge fumes as you paint. Not for use with hazardous, flammable, or explosive materials.
Static-Dissipative Adjustable-Arm Bench-Top Air Cleaners

Eliminate static buildup while cleaning air.
Overall | Housing | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Ht. | Wd. | Dp. | For Max. Surface Thick. | Arm Reach | Material | Color | Surface Resistivity, ohms | Includes | For Removing | Each | |
105 | 38 dB @ 15 ft. | 1/40 | 120V AC | 0.1A | 8 1/2" | 8 1/4" | 4" | 2 1/2" | 24" | Plastic | Black | 109 | Disposable Odor-Removal Filter | Odors and Fumes | 0000000 | 0000000 |
Replacement Filters (Pkg. of 3) | 0000000 | Pkg. | 000000 |
Combination Mobile/Bench-Top Air Cleaners


Roll this air cleaner to the contaminant source or place it on a bench top. Attach the included plastic hood to use as an air cleaning booth.
Includes a prefilter; all other filters sold separately.
Standard filter captures 95% of particles down to 3 microns.
HEPA filter captures 99.97% of particles down to 0.3 microns.
Odor-removal filter has carbon to remove odors. It includes a pleated filter that captures 60% of particles down to 3 microns.
Add an odor-removal after-filter to standard and HEPA filters for light duty odor control.
Overall | Hose | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Includes | For Removing | Each | |
350 | 58 dB @ 15 ft. | 1/4 | 120V AC | 2.8A | 2 1/2" | 19 1/2" | 12 1/2" | 12 1/2" | Powder-Coated Steel | 4 | Plastic | Disposable Prefilter, Plastic Hood | Dust and Particles, Odors and Fumes | 0000000 | 000000000 |
Odor-Removal After-Filters | 0000000 | Each | 0000000 |
Odor-Removal Filters | 0000000 | Each | 000000 |
Replacement Prefilters (Pkg. of 4) | 0000000 | Pkg. | 00000 |
HEPA Filters | 0000000 | Each | 000000 |
Standard Filters | 0000000 | Each | 000000 |
Replacement Pleated Filters for Odor-Removal Filters and After-Filters | 0000000 | Each | 00000 |
Replacement Carbon for Odor-Removal Filters and After-Filters | 0000000 | Each | 000000 |
Static-Dissipative Bench-Top Air Cleaners

Eliminate static buildup while cleaning air.
Bench-Top Air Cleaners
Bench-Top Air Cleaner Hoods
Filtering away dust and particles, these hoods create a clean space for demanding work, such as bioprocessing, pharmaceuticals, electronics, and optics. They have a HEPA H14 filter to catch 99.995% of particles down to 0.1 microns, as well as a pre-filter to pull out large particles before they reach the HEPA filter. To draw air from outside the hood into the filters, they have a fan; there’s no need to connect them to ductwork. A flow monitor tracks the airflow and alerts you with a visible and audible alarm if the fan fails. They meet Fed. Std. Class 100 and ISO Class 5 clean room requirements.
As an alternative to filtering the air of an entire room, these hoods leave a large enough opening for comfortable access inside and have internal fluorescent lighting to help you see your work. Their work surface is 304L stainless steel, which resists bacteria and chemicals, and also is easy to clean. Mount them on workbenches and carts that are designed to hold them, or place them on your own bench top.
These hoods cannot be sold to California.
For technical drawings and 3-D models, click on a part number.

Overall | Work Surface | Housing | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Ht. | Wd. | Dp. | Wd. | Dp. | Material | Color | Panel Cutout Dia. | Environmental Rating | Cannot Be Sold To | Each | |
304L Stainless Steel Work Surface with Acrylic Enclosure | |||||||||||||||
Hoods | |||||||||||||||
185 | 59 dB @ 5 ft. | 120V AC | 3A | 47 3/4" | 31 3/4" | 24 1/4" | 26 1/2" | 20 1/2" | Plastic | Black, Blue, White | 2 7/8" | Fed. Std. Class 100, ISO Class 5 | CA | 0000000 | 000000000 |
Overall | ||||||
---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Material | Caster Type | Each | |
Mobile | ||||||
34 7/8" | 30 3/4" | 24 1/4" | Galvanized Steel | Four Swivel (Two with Brakes) | 0000000 | 0000000 |
Adjustable-Arm Bench-Top Air Cleaners

Overall | Housing | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Ht. | Wd. | Dp. | For Max. Surface Thick. | Arm Reach | Material | Color | Includes | For Removing | Each | |
105 | 38 dB @ 15 ft. | 1/40 | 120V AC | 0.1A | 8 1/2" | 8 1/4" | 4" | 2 1/2" | 24" | Plastic | White | Disposable Odor-Removal Filter | Odors and Fumes | 0000000 | 0000000 |
Replacement Filters (Pkg. of 3) | 0000000 | Pkg. | 000000 |