Connection Style Connection Style |
---|
![]() |
Threaded |
![]() |
Socket Connect |
Pipe Size Pipe Size | Show |
---|
|
For Use With For Use With |
---|
Type Type |
---|
![]() | ![]() |
Connector | Reducing Adapter |
![]() | |
Valve |
Maximum Pressure Maximum Pressure |
---|
|
System of Measurement System of Measurement |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Color Color |
---|
![]() | White |
![]() | Dark Gray |
![]() | Light Gray |
Socket Depth Socket Depth |
---|
|
Screen Construction Screen Construction |
---|
|
Screen Material Screen Material |
---|
|
Specifications Met Specifications Met |
---|
|
Maximum Steam Pressure Maximum Steam Pressure |
---|
|
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
More
More
Use these fittings for low-pressure applications in noncorrosive environments.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Max. Pressure | Max. Steam Pressure | Material | Each | |
NPT Female | |||||
---|---|---|---|---|---|
2 1/2 | 150 psi @ 72° F | 150 psi @ 350° F | Black-Coated Iron | 000000000 | 0000000 |
The galvanized finish on these fittings provides fair corrosion resistance. Fittings are for use in low-pressure applications.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Max. Pressure | Max. Steam Pressure | Material | Each | |
NPT Female | |||||
---|---|---|---|---|---|
2 1/2 | 150 psi @ 72° F | 150 psi @ 350° F | Galvanized Iron | 00000000 | 0000000 |
Use these fittings in low-pressure flow applications. They have good corrosion resistance. Fittings rated for use with drinking water meet NSF/ANSI 61 safety standards.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Max. Pressure | Material | Each | |
NPT Female | ||||
---|---|---|---|---|
2 1/2 | 200 psi @ 72° F | Brass | 00000000 | 0000000 |
Connect these fittings to Schedule 40 plastic pipe–they are the industry standard for residential and commercial low-pressure plumbing and water supply applications. They are plastic for good corrosion resistance.
Fittings for drinking water meet NSF/ANSI Standard 61.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
Fittings that meet ASTM D1784, ASTM D1785, and ASTM D4066 adhere to specifications and testing requirements for material quality.
Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Connect these fittings to Schedule 80 pipe–they have thicker, stronger walls than standard-wall fittings so they can handle heavy duty industrial plumbing and water supply applications, such as water processing, waste water treatment, and irrigation. Fittings are plastic for good corrosion resistance. They meet ASTM D1784 specifications and testing requirements for material quality.
Fittings for drinking water meet NSF/ANSI Standard 61.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Socket Depth | Material | Color | Each | |
2 1/2 | 1 3/4" | PVC Plastic | Dark Gray | 00000000 | 0000000 |
Type | Each | |
Cement Adhesive for 6" Maximum Pipe Dia. | 00000000 | 00000 |
Made of CPVC, these fittings can handle high temperatures up to 200° F. They connect to Schedule 80 pipe and have thick, strong walls to handle heavy duty industrial plumbing and water supply applications, such as water processing and waste water treatment. Fittings have good corrosion resistance. They meet ASTM D1784 specifications and testing requirements for material quality. They are comparable to Corzan.
Fittings for drinking water meet NSF/ANSI Standard 61.
Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a CPVC primer and cement (also known as solvent weld).
Control the flow of water in two directions from a single source—these diverting valves have two balls and handles for independent operation of each outlet. They can direct flow to one side outlet at full capacity while shutting off flow to the second side outlet, direct flow to both side outlets at reduced capacity, or shut off flow to both side outlets. Valves have a brass body for good corrosion resistance. They are for use with fire-fighting hose.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Male NPSH (National Pipe Straight Hose) threads are compatible with female NPSH threads. Female NPSH threads are compatible with male NPSH, NPT, NPTF, and NPSM threads.
For technical drawings and 3-D models, click on a part number.
Inlet Pipe Size | Outlet Pipe Sizes | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Brass Body | ||||||||
---|---|---|---|---|---|---|---|---|
2 1/2 | 1 1/2 × 1 1/2 | Y-Pattern | Not Rated | 300 psi @ 150° F | -20° to 150° | 5 5/8" | 000000 | 0000000 |
Install these strainers prior to valves, pumps, and nozzles to catch debris in your pipeline and protect sensitive equipment. They are designed for low-pressure applications. Strainers have a threaded drain with a plug that provides access to the screen without disconnecting your line. They are bronze for good corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Strainers | Replacement Screens | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Lg. | Ht. | Plug Pipe Size | Screen Material | Screen OD | Screen Lg. | Choose a Screen Mesh Size | Choose a Screen Opening Size | Each | Each | ||
With Mesh Screen | |||||||||||||
2 1/2 | NPT | 9" | 7 3/4" | 1/2 | 304 Stainless Steel | 2 5/8" | 5 7/16" | 20 | __ | 00000000 | 0000000 | 000000000 | 0000000 |
2 1/2 | NPT | 9" | 7 3/4" | 1/2 | 304 Stainless Steel | 2 47/64" | 5 7/16" | __ | 00000000 | 000000 | 00000000 | 000000 | |
With Perforated Screen | |||||||||||||
2 1/2 | NPT | 9" | 7 3/4" | 1/2 | 304 Stainless Steel | 2 3/4" | 5 7/16" | __ | 000000000 | 000000 | 000000000 | 000000 |
Strainers catch debris in your pipeline, preventing damage to valves, pumps, nozzles, and other sensitive equipment. They are designed for medium-pressure applications. Strainers have a threaded drain with a plug that provides access to the screen without disconnecting your line. They have good corrosion resistance.
For technical drawings and 3-D models, click on a part number.
A rugged iron body provides excellent strength and durability. Strainers prevent damage to valves, pumps, nozzles, and other sensitive equipment by catching debris in your pipeline. They are designed for low-pressure applications. Strainers are for use in noncorrosive environments. They have a threaded drain with a plug that provides access to the screen without disconnecting your line.
For technical drawings and 3-D models, click on a part number.
Strainers | Replacement Screens | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Lg. | Ht. | Plug Pipe Size | Screen Material | Choose a Screen Mesh Size | Choose a Screen Opening Size | Each | Each | ||
With Mesh and Perforated Screen | ||||||||||
2 1/2 | 8 7/8" | 9 3/4" | 1 1/4 | 304 Stainless Steel | __ | 0000000 | 0000000 | 0000000 | 000000 | |
2 1/2 | 8 7/8" | 9 3/4" | 1 1/4 | 304 Stainless Steel | 20 | __ | 0000000 | 000000 | 0000000 | 000000 |
With Perforated Screen | ||||||||||
2 1/2 | 8 7/8" | 9 3/4" | 1 1/4 | 304 Stainless Steel | __ | 0000000 | 000000 | 0000000 | 00000 |
PVC construction is lightweight and provides excellent corrosion resistance. Install them prior to valves, pumps, and nozzles to catch debris in your pipeline and protect sensitive equipment. Strainers have a threaded drain with a hex cap or plug that provides access to the screen without disconnecting your line.
Strainers with socket-connect pipe connections attach to unthreaded pipe with cement for a permanent, leak-tight connection.
For technical drawings and 3-D models, click on a part number.
Strainers | Replacement Screens | Replacement Caps | Replacement Gaskets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Socket Connect Type | Lg. | Ht. | For Fitting Schedule | For Pipe Schedule | Features | Choose a Screen Opening Size | Each | Each | Each | Each | ||||
Dark Gray Strainer with PVC Plastic Screen | |||||||||||||||
2 1/2 | Cement | 10 5/16" | 9 3/4" | 80 | 80 | Threaded Drain with Hex Cap | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |
To achieve the maximum possible flow, internal components are designed to reduce flow resistance. These valves open to allow flow in one direction and close when flow stops or reverses. A removable cap provides easy access to internal components for maintenance.
Repair kits include everything you need to rebuild the valve.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Valves | Repair Kits | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Disc Material | Seal Material | End-to-End Lg. | Features | Each | Each | ||
NPT Female × NPT Female—200 Pressure Class | |||||||||||||
2 1/2 | 150 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 7" | Removable Cap | 0000000 | 0000000 | 00000000 | 0000000 |
NPT Female × NPT Female—300 Pressure Class | |||||||||||||
2 1/2 | 150 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 7" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |