Shape Shape | Show |
---|
![]() | Straight |
Shape Shape | Hide |
---|
![]() | ![]() |
Wye | Double Wye |
![]() | ![]() |
Tee | Straight |
Thread Type Thread Type |
---|
|
Connection Style Connection Style |
---|
![]() | Threaded |
![]() | Socket Connect |
![]() | Solder Connect |
For Use With For Use With |
---|
Check Valve Type Check Valve Type |
---|
|
Valve Type Valve Type |
---|
|
Mounting Orientation Mounting Orientation |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
System of Measurement System of Measurement |
---|
|
End-to-End Length End-to-End Length |
---|
Valve Function Valve Function |
---|
|
Actuation Actuation |
---|
|
Specifications Met Specifications Met |
---|
|
Fitting Type Fitting Type |
---|
|
More
To achieve the maximum possible flow, internal components are designed to reduce flow resistance. These valves open to allow flow in one direction and close when flow stops or reverses. A removable cap provides easy access to internal components for maintenance.
Repair kits include everything you need to rebuild the valve.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Valves | Repair Kits | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Disc Material | Seal Material | End-to-End Lg. | Features | Each | Each | ||
NPT Female × NPT Female—150 Pressure Class | |||||||||||||
1/4 | 2.3 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
3/8 | 4.3 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 00000 | 000000 | 00 |
1/2 | 7.2 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 2 5/8" | Removable Cap | 0000000 | 00000 | 000000 | 00 |
3/4 | 13 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 3" | Removable Cap | 0000000 | 00000 | 000000 | 00 |
1 | 22 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 3 11/16" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
1 1/4 | 39 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 4 3/8" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
1 1/2 | 56 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Brass | Brass | 4 5/8" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
2 | 92 | 300 psi @ 150° F | 150 psi @ 366° F | 0.5 | -20° to 405° | Bronze | Bronze | 5 7/8" | Removable Cap | 0000000 | 000000 | 000000 | 00 |
NPT Female × NPT Female—200 Pressure Class | |||||||||||||
1/4 | 2.3 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 00000 | 00000000 | 000000 |
3/8 | 4.3 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 00000 | 00000000 | 00000 |
1/2 | 7.2 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 5/8" | Removable Cap | 0000000 | 00000 | 00000000 | 00000 |
3/4 | 13 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 3" | Removable Cap | 0000000 | 00000 | 00000000 | 00000 |
1 | 22 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 3 11/16" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 1/4 | 39 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 3/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 1/2 | 56 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 5/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
2 | 92 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 5 7/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
2 1/2 | 150 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 7" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
3 | 240 | 400 psi @ 150° F | 200 psi @ 388° F | 0.5 | -20° to 550° | Bronze | Bronze | 7 7/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000000 |
NPT Female × NPT Female—300 Pressure Class | |||||||||||||
1/4 | 2.3 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 00000 | 00000000 | 00000 |
3/8 | 4.3 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 1/4" | Removable Cap | 0000000 | 00000 | 00000000 | 00000 |
1/2 | 7.2 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 2 5/8" | Removable Cap | 0000000 | 00000 | 00000000 | 00000 |
3/4 | 13 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 3" | Removable Cap | 0000000 | 00000 | 00000000 | 00000 |
1 | 22 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 3 11/16" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 1/4 | 39 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 3/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
1 1/2 | 56 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 4 5/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
2 | 92 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 5 7/8" | Removable Cap | 0000000 | 000000 | 00000000 | 00000 |
2 1/2 | 150 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 7" | Removable Cap | 0000000 | 000000 | 00000000 | 000000 |
3 | 240 | 600 psi @ 150° F | 300 psi @ 422° F | 0.5 | -20° to 550° | Bronze | Bronze | 7 7/8" | Removable Cap | 0000000 | 00000000 | 00000000 | 00000000 |
Visually inspect flow and debris accumulation through the transparent valve body. Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. These valves open to allow flow in one direction and close when flow stops or reverses. They have a removable cap that provides easy access to internal components for maintenance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Features | Each | |
PVC Plastic Body | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Socket Connect × Socket Connect | ||||||||||
1/2 | 40, 80 | 6.7 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 5 5/8" | Removable Cap | 0000000 | 000000 |
3/4 | 40, 80 | 11.9 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 5/16" | Removable Cap | 0000000 | 00000 |
1 | 40, 80 | 21 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 7/8" | Removable Cap | 0000000 | 00000 |
1 1/2 | 40, 80 | 49 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 8 1/8" | Removable Cap | 0000000 | 000000 |
2 | 40, 80 | 77 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 8 7/8" | Removable Cap | 0000000 | 000000 |
3 | 40, 80 | 168 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 12 1/4" | Removable Cap | 0000000 | 000000 |
Solder these valves to copper tubing for a permanent, leak-tight connection. They open to allow flow in one direction and close when flow stops or reverses. All have a removable cap that provides easy access to internal components for maintenance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Copper Tube Size | For Tube OD | Flow Coefficient (Cv) | Pressure Class | Max. Pressure | Max. Steam Pressure | Min. Opening Pressure, psi | Temperature Range, °F | End-to-End Lg. | Features | Each | |
Bronze Body | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Solder Connect × Solder Connect | |||||||||||
1/4 | 3/8" | 1.3 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 2 1/16" | Removable Cap | 0000000 | 000000 |
3/8 | 1/2" | 2.5 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 2 1/16" | Removable Cap | 0000000 | 00000 |
1/2 | 5/8" | 4.8 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 2 9/16" | Removable Cap | 0000000 | 00000 |
3/4 | 7/8" | 14.3 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 3 3/8" | Removable Cap | 0000000 | 00000 |
1 | 1 1/8" | 24 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 4 1/16" | Removable Cap | 0000000 | 000000 |
1 1/2 | 1 5/8" | 60 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 5 1/4" | Removable Cap | 0000000 | 000000 |
2 | 2 1/8" | 102 | 125 | 200 psi @ 70° F | 125 psi @ 350° F | 0.5 | -20° to 405° | 6 3/8" | Removable Cap | 0000000 | 000000 |
Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. These valves have a plastic body and a fluoroelastomer seal for excellent chemical resistance. They open to allow flow in one direction and close when flow stops or reverses.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Each | |
Socket Connect × Socket Connect | |||||||||
---|---|---|---|---|---|---|---|---|---|
3/4 | 40, 80 | 3 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 4 3/16" | 000000 | 0000000 |
1 | 40, 80 | 9 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 5 3/16" | 000000 | 000000 |
1 1/4 | 40, 80 | 26 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 6 5/8" | 000000 | 000000 |
1 1/2 | 40, 80 | 45 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 6 5/8" | 000000 | 000000 |
2 | 40, 80 | 65 | 150 psi @ 70° F | 2 | 40° to 140° | Dark Gray | 7 5/8" | 000000 | 000000 |
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Each | |
Socket Connect × Socket Connect | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2 | 40, 80 | 0.8 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 3 3/8" | 0000000 | 0000000 |
3/4 | 40, 80 | 3 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 4 3/16" | 0000000 | 000000 |
1 | 40, 80 | 9 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 5 3/16" | 0000000 | 000000 |
1 1/4 | 40, 80 | 26 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 6 5/8" | 0000000 | 000000 |
1 1/2 | 40, 80 | 45 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 6 5/8" | 0000000 | 000000 |
2 | 40, 80 | 65 | 150 psi @ 70° F | 2 | 40° to 190° | Light Gray | 7 5/8" | 0000000 | 000000 |
Visually inspect flow and debris accumulation through the transparent valve body. Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. Valves have a PVC body and a fluoroelastomer seal for excellent chemical resistance. They open to allow flow in one direction and close when flow stops or reverses. All have a removable cap that provides easy access to internal components for maintenance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | Color | End-to-End Lg. | Features | Each | |
PVC Plastic Body | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Socket Connect × Socket Connect | ||||||||||
1/2 | 40, 80 | 6.7 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 5 5/8" | Removable Cap | 0000000 | 000000 |
3/4 | 40, 80 | 11.9 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 5/16" | Removable Cap | 0000000 | 00000 |
1 | 40, 80 | 21 | 150 psi @ 70° F | 0.29 | 35° to 140° | Clear | 6 7/8" | Removable Cap | 0000000 | 00000 |