McMaster-Carr logo
    Filter by
    Frequency
    Output Electrical Connection
    Input Electrical Connection
    For Use Outdoors
    Electrical Connection Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Case Material
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    70 Products

    Programmable LED Drivers

    Image of Product. Driver. Front orientation. LED Drivers. Programmable LED Drivers.
    Image of Product. Programmer for Advance Drivers. Front orientation. Advance Series. Programmable LED Drivers.

    Driver

    Programmer for Advance

    Drivers

    Image of Product. Programmer for FieldSET Drivers. Front orientation. FieldSET Series. Programmable LED Drivers.

    Programmer

    for

    FieldSET

    Drivers

    Match the brightness of your other lights when replacing a failed LED driver. These drivers let you program the output current to the exact level you need. Because they cover a wide range of currents, you don’t need to have multiple different ones on hand for repairs. They convert your building’s AC voltage into the constant low-voltage DC power your LEDs need.
    To select the right driver, match its output wattage to the label on your existing driver. If there’s no exact match, round up to the nearest wattage.
    Taptronic Series—Taptronic drivers are programmed with a free downloadable app on your iPhone or Android device. Enter the settings from the old driver’s label. Then tap the new driver to your device to transfer the settings wirelessly.
    Advance Series—Advance drivers are programmed with a free downloadable Android app or a Signify Advance programmer (sold separately) connected to your PC. Enter the settings from the old driver’s label. Then tap the new driver to your Android device or programmer to transfer the settings wirelessly.
    FieldSET Series—FieldSET drivers are programmed with an eldoLED FieldSET programmer (sold separately). The programmer doesn’t require a PC, making it ideal for frequent replacements. It's rugged and can survive drops from up to 10 ft. The programmer automatically copies settings from old FieldSET and Optotronic drivers—just connect them using the programmer's cord. Then connect your new FieldSET driver to transfer the settings. If your old driver is from another brand, you’ll need to manually enter the settings from the label.
    Fastener Mount—Fastener mount drivers are secured using the screws from your original driver.
    Threaded-Stud Mount—Threaded stud mount drivers are secured by pushing the studs on the bottom of the driver through existing holes in the fixture and tightening with an 8-32 nut (not included).
    IP66 Enclosure Rating—Drivers that meet IP66 are protected from dust and high-pressure washdowns. They’re safe for use as replacements in outdoor fixtures exposed to rain and wet conditions.
    LED Drivers
    Programmers
    Output
    Input
    Wattage,
    W
    Current,
    A
    Voltage,
    V DC
    Wattage,
    W
    Voltage,
    V AC
    Light Intensity
    Setting
    Dimming
    Range
    Lg.
    Wd.
    Ht.
    Mount Type
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Each
    Constant-Current Driver
     
    Taptronic Series
    250.15-1.258-5529120 to 277Dimmable1% to 100%5 1/8"2 7/16"1 1/16"Fastener-20 to 120IP20
    8097N11000000———0
    250.15-1.258-5529120 to 277Dimmable1% to 100%5 1/8"2 7/16"1 1/16"Threaded Stud-20 to 120IP20
    8097N1200000———0
    360.1-120-4842120 to 277Dimmable1% to 100%9 1/2"1 1/4"1 1/8"Fastener-20 to 120IP20
    8097N1300000———0
    400.4-1.48-5546120 to 277Dimmable1% to 100%5 1/8"2 7/16"1 1/16"Fastener-20 to 120IP20
    8097N1400000———0
    400.4-1.48-5546120 to 277Dimmable1% to 100%5 1/8"2 7/16"1 1/16"Threaded Stud-20 to 120IP20
    8097N1500000———0
    500.14-1.48-5550120 to 347Dimmable1% to 100%11"1 3/16"13/16"Fastener-20 to 120IP20
    8097N11600000———0
    880.24-2.424-48102120 to 277Dimmable1% to 100%9 1/2"1 3/4"1 3/16"Fastener-20 to 120IP20
    8097N1700000———0
    1000.35-1.2550-185110120 to 277Dimmable10% to 100%9 1/2"2 3/8"1 1/2"Fastener-40 to 120IP66
    8097N1800000———0
    1800.35-1.2570-280198120 to 277Dimmable10% to 100%9 1/2"2 3/8"1 1/2"Fastener-40 to 120IP66
    8097N1900000———0
     
    Advance Series
    300.1-1.212-4035120 to 277Dimmable10% to 100%6 5/8"1 3/4"1 1/8"Fastener-40 to 1304305N161000008112N1210000000
    500.1-1.510-5458120 to 277Dimmable1% to 100%11"1 3/16"1"Fastener0 to 1204305N225000008112N121000000
    540.1-1.527-465120 to 277Dimmable1% to 100%14 3/16"1 3/16"1"Fastener0 to 1204305N125000008112N121000000
    550.1-1.818-5464120 to 277Dimmable1% to 100%6 5/8"1 3/4"1 1/8"Fastener-40 to 1304305N162000008112N121000000
    750.1- 227-486120 to 277Dimmable1% to 100%16 5/8"1 3/16"1"Fastener0 to 1204305N126000008112N121000000
    750.1- 227-487120 to 277Dimmable1% to 100%6 1/4"3"1 5/16"Fastener0 to 1204305N131000008112N121000000
    1000.1-1.148-43114120 to 277Dimmable10% to 100%9 1/2"2 3/8"1 1/2"Fastener-40 to 1304305N164000008112N121000000
    1500.1- 225-50175120 to 277Dimmable10% to 100%9 7/16"2 5/16"1 1/2"Fastener-40 to 1304305N288000008112N121000000
    1800.1-0.9100-285200120 to 277Dimmable10% to 100%9 1/2"2 5/16"1 1/2"Fastener-40 to 1304305N223000008112N121000000
    1800.1-1.2570-210198120 to 277Dimmable10% to 100%9 1/2"2 3/8"1 1/2"Fastener-40 to 1304305N168000008112N121000000
    1800.1-1.2570-210200347 to 480Dimmable10% to 100%9 1/2"2 5/16"1 1/2"Fastener-40 to 1304305N169000008112N121000000
     
    FieldSET Series
    250.15-1.258-5533120 to 277Dimmable1% to 100%4 3/16"2 3/8"1 3/16"Threaded Stud-20 to 120IP20
    8097N22000008112N122000000
    250.15-1.258-5533120 to 277Dimmable1% to 100%4 5/16"2 3/8"1 3/16"Fastener-20 to 120IP20
    8097N21000008112N122000000
    300.15-1.0510-5541120 to 277Dimmable1% to 100%11"1 1/8"1"Fastener-20 to 120IP20
    8097N23000008112N122000000
    400.4-1.48-5549120 to 277Dimmable1% to 100%4 3/16"2 3/8"1 3/16"Threaded Stud-20 to 120IP20
    8097N25000008112N122000000
    400.4-1.48-5549120 to 277Dimmable1% to 100%4 5/16"2 3/8"1 3/16"Fastener-20 to 120IP20
    8097N24000008112N122000000
    500.4-1.410-5563120 to 277Dimmable1% to 100%11"1 1/8"1"Fastener-20 to 120IP20
    8097N26000008112N122000000
    850.7-2.310-5599120 to 277Dimmable1% to 100%16 3/4"1 1/8"1"Fastener-40 to 130IP20
    8097N27000008112N122000000
    1000.6-1.2530-100114120 to 277Dimmable10% to 100%6 5/8"2 3/8"1 1/2"Fastener-40 to 130IP66
    8097N28000008112N122000000
    1800.6-1.2570-210192277 to 480Dimmable10% to 100%9 1/2"2 3/8"1 1/2"Fastener-40 to 130IP66
    8097N290000008112N122000000
     

    LED Drivers

    Image of Product. Front orientation. LED Drivers. LED Drivers.
    Bring your LED light back to life without the cost and hassle of replacing the entire fixture. These drivers replace your light’s failed driver and convert your building’s AC voltage into the low-voltage DC power your LEDs need. They also shield your lights from damaging voltage and current fluctuations.
    To select the right driver, match its output wattage to the label on your existing driver. If there’s no exact match, round up to the nearest wattage.
    Constant-Current Driver—Constant current drivers are the most common and are often used with commercial and industrial lighting. They’re best for consistent brightness. Those with multiple output currents include a switch, so you can select the output current closest to your needs. Keep them on hand to replace drivers with varying current requirements.
    Constant-Voltage Driver—Constant voltage drivers are best for long runs of lights, such as strip or tape lights, to maintain stable voltage. Rated IP65, they’re protected from dust and low-pressure jets of water. They’re safe for use as replacements in outdoor fixtures exposed to rain and wet conditions.
    LED Driver Type—Drivers with constant current or constant voltage perform one function at a time. They automatically detect the light’s requirements and supply the appropriate type of power.
    Output
    Input
    Wattage,
    W
    Current, A
    Voltage, V DC
    Wattage,
    W
    Voltage,
    V AC
    Light Intensity
    Setting
    Dimming
    Range
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Constant-Current Driver
    160.25, 0.3, 0.35, 0.430-4222120 to 277Dimmable10% to 100%3 3/8"1 7/8"1 1/8"-10 to 100IP20
    4305N511000000
    160.3, 0.35, 0.430-4230120 to 277Dimmable10% to 100%11"1 3/16"13/16"-10 to 100IP20
    4305N51200000
    240.45, 0.5, 0.5530V DC to 45V DC40120 to 277Dimmable10% to 100%11"1 3/16"7/8"-10 to 120IP20
    4305N53400000
    250.45, 0.5, 0.55, 0.630-4231120 to 277Dimmable10% to 100%3 3/8"1 7/8"1 1/8"-10 to 100IP20
    4305N51300000
    310.6, 0.65, 0.730V DC to 45V DC40120 to 277Dimmable10% to 100%11"1 3/16"7/8"-10 to 120IP20
    4305N53500000
    330.65, 0.7, 0.75, 0.830-4242120 to 277Dimmable10% to 100%3 3/8"1 7/8"1 1/8"-10 to 100IP20
    4305N51600000
    350.75, 0.8, 0.8530-4253120 to 277Dimmable10% to 100%11"1 3/16"7/8"-10 to 120IP20
    4305N53800000
    400.85, 0.9, 0.95, 130-4050120 to 277Dimmable10% to 100%3 3/8"1 7/8"1 1/8"-10 to 100IP20
    4305N51700000
    400.9, 0.95, 130-4053120 to 277Dimmable10% to 100%11"1 3/16"13/16"-10 to 100IP20
    4305N52900000
    481.05, 1.1, 1.1530-4267120 to 277Dimmable10% to 100%11"1 3/16"13/16"-10 to 100IP20
    4305N53100000
    541.2, 1.25, 1.330-4273120 to 277Dimmable10% to 100%11"1 3/16"13/16"-10 to 100IP20
    4305N52200000
    1501.0542-142164347 to 480Dimmable10% to 100%9 1/2"2 5/16"1 1/2"-40 to 1304305N15900000
    1501.0544-140169120 to 277Dimmable10% to 100%9 1/2"2 3/8"1 1/2"-40 to 1304305N15800000
     
    Constant-Voltage Driver
    600-2.52470120 to 277Dimmable0.1% to 100%9 1/2"1 3/4"1 3/16"-40 to 125IP65
    4305N52400000
    600-51278120 to 277Dimmable0.1% to 100%9 1/2"1 3/4"1 3/16"-40 to 125IP65
    4305N52300000
    960-424111120 to 277Dimmable0.1% to 100%9 1/2"1 3/4"1 3/16"-40 to 125IP65
    4305N52500000
     
    Constant-Current Driver or Constant-Voltage Driver
    770.1-3.2, 3.224, 12-2490120 to 2779 1/2"1 3/4"1 1/8"-40 to 1304305N14200000
    1000.1-4.1, 4.124, 12-24115120 to 2779 1/2"1 3/4"1 1/8"-40 to 1304305N14300000
     

    Tape Lights

    Bend these flexible lights around corners or squeeze them into spaces where bulky fixtures won’t fit. They’re brighter than plug-in tape lights, so you can use them for inspections and other detailed work. They’re also a great choice to extend the life of your fluorescent or incandescent fixtures with energy-efficient LEDs. They have a higher CRI (color rendering index) than most other lights, so they illuminate subtle color differences. Each LED is inspected to make sure there are no visible differences in temperature and brightness, so you can combine multiple strips within the same space. Install them on any smooth surface—just peel and stick.
    You’ll need a driver to power these lights. Customize your setup: join multiple lights together, use connectors to bridge gaps between stairs or shelves, or add channels to diffuse light within your space (all sold separately).
    Note: To shorten a light, cut it at the marked intervals only. Cutting outside these marks can damage the circuit and create dead zones.
    Drivers
    Image of Product. Front orientation. Tape Lights. Tape Lights, Drivers.
    Drivers provide a constant voltage to your tape lights, protecting the LEDs from power fluctuations. Built-in thermal protection helps extend the lifespan of these drivers, and they’re housed in a UL-listed enclosure suitable for wet locations. To install, feed the power source and tape light wire leads through the knockouts. Seal the entry points using a 1/2 trade size conduit fitting or cord grip. Inside the enclosure, connect the wire leads using the included lever connectors. Do not exceed the recommended tape length; to power longer lights, add another driver.
    IP67 Enclosure Rating—Drivers rated IP67 are sealed to withstand dust and temporary submersion.
    Output
    Input
    For Tape
    Lg., ft.
    Electrical
    Connection Type
    Voltage,
    V DC
    Current,
    amp
    Wattage,
    W
    Electrical
    Connection
    Current,
    amp
    Max. Wattage,
    W
    Electrical
    Connection
    Light Intensity
    Setting
    Lg.
    Wd.
    Ht.
    Enclosure
    Rating
    Certification
    Includes
    Each
    100V AC to 277V AC Input Voltage
    7 to 10Hardwire242.560Wire Leads0.771Wire LeadsDimmable9 3/16"3 3/8"1 15/16"IP67
    UL Listed, C-UL Listed, UL Recognized Component, C-UL Recognized Component, CE Marked, FCC Compliant
    Two Clamp-On Wire Splicing Connectors8836N25000000
    11 to 16Hardwire24496Wire Leads1113Wire LeadsDimmable9 3/16"3 3/8"1 15/16"IP67
    UL Listed, C-UL Listed, UL Recognized Component, C-UL Recognized Component, FCC Compliant
    Two Clamp-On Wire Splicing Connectors8836N2400000
     
    120V AC to 277V AC Input Voltage
    0 to 6Hardwire241.6640Wire Leads0.4347Wire LeadsDimmable8"2 3/4"1 5/8"IP62
    UL Listed, C-UL Listed, UL Recognized Component, C-UL Recognized Component, CE Marked, FCC Compliant
    Two Clamp-On Wire Splicing Connectors8836N2600000
     

    Programmers for LED Drivers

    Image of Product. Programmer for Advance Drivers. Front orientation. LED Drivers. Programmers for LED Drivers, For Advance Series.
    Image of Product. Programmer for FieldSET Drivers. Front orientation. For FieldSET Series. Programmers for LED Drivers.

    Programmer for Advance

    Drivers

    Programmer

    for

    FieldSET

    Drivers

    Set the output current and dimming level on programmable LED drivers. Choose a programmer that matches the manufacturer series of your new driver.
    For Advance Series—Advance programmers connect to your PC. Key in the settings from the old driver’s label. Then tap the new driver to the programmer to transfer the settings wirelessly.
    For FieldSET Series—FieldSET programmers are handheld and don’t require a PC, making them ideal for frequent replacements. They’re rugged and can survive drops from up to 10 ft. These programmers automatically copy settings from FieldSET and Optotronic drivers—just connect the programming cord to the old driver. Then connect your new FieldSET driver to transfer the settings. These programmers cannot be used to program new Optotronic drivers. If your old driver is from another brand, you’ll need to manually enter the settings from the label.
    For Mfr.
    Series
    Ht.
    Wd.
    Dp.
    Electrical
    Connection
    Cord Lg.,
    ft.
    Batteries
    Included
    Temp. Range,
    ° F
    Display
    Type
    Operating System
    Compatibility
    Includes
    Each
    Advance3/4"3 1/4"5 5/8"USB-A50 to 140Windows 2000 or Later8112N1210000000
    FieldSET6 1/2"3 1/8"1 1/8"Yes32 to 130LCD3 ft. Lg. Programming Cord8112N122000000

    Retrofit Kits for Ceiling and Wall Lights

    Upgrade your old fixtures to energy-efficient LED lights. These kits replace the need to maintain hard-to-find-bulbs and ballasts, or replace the entire fixture. They fit inside fluorescent or incandescent fixtures and wire directly to power, so they’re quick to install. Choose a kit that matches your fixture’s shape and size. They come with everything you need to plug in and go. They either include driver circuitry on the circuit board or come with a driver. To install, remove all the old bulbs and the fixture’s wiring.
    Select a light appearance to match your existing lighting. If you’re not sure what light appearance your existing fixtures have, choose a light with a selectable light appearance. Use the switch to adjust its appearance and brightness.
    Round—120V AC Input Voltage
    Image of Product. Front orientation. Light Retrofit Kits. Retrofit Kits for Ceiling and Wall Lights, Round—120V AC Input Voltage.
    Image of Product. With Driver (Shown Expanded). Front orientation. Light Retrofit Kits. Retrofit Kits for Ceiling and Wall Lights, Round—120V AC Input Voltage, Driver.
    Image of Product. With Driver. Front orientation. Light Retrofit Kits. Retrofit Kits for Ceiling and Wall Lights, Round—120V AC Input Voltage, Driver.

    With Driver (Shown Expanded)

    With Driver

    Round kits fit into small ceiling and wall fixtures. They come with a plastic cover to keep you from touching the live circuit board. To install, just push your power wires into the connectors on the board.
    Magnet Mount—Magnetic kits snap onto steel and other magnetic housings—no drilling or fasteners required.
    Overall
    Dia.
    Ht.
    Brightness
    Max. Input
    Wattage
    Light Intensity
    Setting
    Mounting
    Location
    Mount Type
    Mounting Hardware
    Included
    Certification
    Includes
    Light Appearance (Color Temp.)
    Each
    LED
    3 1/8"3/4"980 lm10 WDimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (2,700 K), Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K), Cool (5,000 K)8229N113000000
    5 1/8"3/4"1,500 lm
    2,000 lm
    15 W
    20 W
    DimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (2,700 K), Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K), Cool (5,000 K)8229N11400000
    6 3/4"3/4"1,500 lm
    2,000 lm
    25 W
    30 W
    DimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (2,700 K), Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K), Cool (5,000 K)8229N11500000
    9" to 12"1 1/4"800 lm
    1,200 lm
    1,800 lm
    6.5 W
    10 W
    15 W
    DimmableCeilingFastener, MagnetYesETL Listed, C-ETL Listed
    DriverWarm (3,000 K), Neutral (3,500 K), Neutral (4,000 K),8229N13300000
     
    Rectangle—120V AC Input Voltage
    Image of Product. Front orientation. Light Retrofit Kits. Retrofit Kits for Ceiling and Wall Lights, Rectangle—120V AC Input Voltage.
    Rectangle kits fit into small ceiling and wall fixtures. They come with a plastic cover to keep you from touching the live circuit board. To install, just push your power wires into the connectors on the board.
    Overall
    Lg.
    Wd.
    Ht.
    Brightness
    Max. Input
    Wattage
    Light Intensity
    Setting
    Mounting
    Location
    Mount
    Type
    Mounting Hardware
    Included
    Certification
    Light Appearance (Color Temp.)
    Each
    LED
    6 1/4"2 1/2"3/4"980 lm10 WDimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (2,700 K), Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K), Cool (5,000 K)8229N116000000
     
    Rectangle—120V AC to 277V AC Input Voltage
    Image of Product. Front orientation. Light Retrofit Kits. Retrofit Kits for Ceiling and Wall Lights, Rectangle—120V AC to 277V AC Input Voltage.
    Rectangle kits fit into small ceiling and wall fixtures. They come with a plastic cover to keep you from touching the live circuit board. To install, just push your power wires into the connectors on the board.
    Overall
    Lg.
    Wd.
    Ht.
    Brightness
    Max. Input
    Wattage
    Light Intensity
    Setting
    Mounting
    Location
    Mount
    Type
    Mounting Hardware
    Included
    Certification
    Choose a Light Appearance (Color Temp.)
    Each
    LED
    5 5/8"2 1/4"3/4"1,100 lm10 WDimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K)8229N136000000
    7 1/2"4"3/4"1,400 lm15 WDimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K)8229N13500000
    11 1/8"2 1/4"3/4"1,600 lm15 WDimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K)8229N13700000
    22 1/8"2 1/4"3/4"3,100 lm30 WDimmableCeiling, WallFastenerYesUL Listed, C-UL Listed
    Warm (3,000 K), Neutral (3,500 K), Neutral (4,000 K)8229N13800000
     
    Strip—120V AC to 277V AC Input Voltage
    Image of Product. Front orientation. Light Retrofit Kits. Retrofit Kits for Ceiling and Wall Lights, Strip—120V AC to 277V AC Input Voltage.
    Strip kits include a driver and LED strips. Use them to retrofit recessed ceiling lights, washdown ceiling lights, and linear bay lights.
    Magnet Mount—Magnetic kits snap onto steel and other magnetic housings—no drilling or fasteners required.
    Overall
    Lg.
    Wd.
    Ht.
    For Ceiling
    Ht., ft.
    Brightness
    Max. Input
    Wattage
    Light Intensity
    Setting
    Mounting
    Location
    Mount
    Type
    Mounting Hardware
    Included
    Certification
    Includes
    Choose a Light Appearance
    (Color Temp.)
    Each
    LED
    44"1 3/4"1/2"12 to 2515,400 lm87.1 WDimmableCeiling, WallFastenerYesUL Listed, C-UL Listed, DLC Listed
    Driver, Four LED StripsNeutral (4,000 K), Cool (5,000 K)8229N1390000000
    48"7/8"1/8"7 to 156,700 lm51 WDimmableCeilingMagnetYesETL Listed, C-ETL Listed
    Driver, Two LED StripsNeutral (4,000 K), Cool (5,000 K)8229N13400000
     

    Light Starters for High-Pressure Sodium Lights

    Image of Product. Front orientation. Light Starters. Light Starters for High-Pressure Sodium Lights.
    Pair these starters with ballasts for high-pressure sodium bulbs.
    For
    Ballast
    For Bulb Wattage,
    W
    Type
    ANSI Number
    Dia.
    Lg.
    Max. Distance
    from Ballast, ft.
    Certification
    Each
    35 to 150MagneticS54, S55, S62, S68, S761 1/4"2"2CSA Certified, UL Recognized Component
    14595K48000000
    150 to 400MagneticS50, S51, S56, S66, S671 1/4"2 1/2"2CSA Certified, UL Recognized Component
    14595K4900000

    Light Starters for Tubular Fluorescent Lights

    Image of Product. Front orientation. Light Starters. Light Starters for Tubular Fluorescent Lights.
    Replace or add starters in preheat magnetic ballasts.
    For
    Ballast
    Light Starter
    Trade No.
    For Bulb Wattage,
    W
    Type
    Start
    Type
    Dia.
    Lg.
    Certification
    Each
    FS-214, 15, 20MagneticPreheat3/4"1 1/2"CSA Certified, UL Listed
    1623K100000
    FS-2525MagneticPreheat3/4"1 1/2"CSA Certified, UL Listed
    1623K80000
    FS-413, 30, 40MagneticPreheat3/4"1 1/2"CSA Certified, UL Listed
    1623K20000
    FS-54, 6, 8MagneticPreheat3/4"1 1/2"UL Listed
    1623K90000

    Light Starters for Metal Halide Lights

    Image of Product. Front orientation. Light Starters. Light Starters for Metal Halide Lights.
    Pair these starters with pulse-start ballasts for metal halide bulbs.
    For Ballast
    For Bulb Wattage,
    W
    Type
    Start
    Type
    ANSI Number
    Dia.
    Lg.
    Each
    50 to 450MagneticPulseM90, M98, M102, M110, M131, M132, M136, M138, M139, M140, M142, M143, M144, M148, M153, M154, M1551 1/4"2 1/2"2373N11000000
    back to top